Loading...
HomeMy WebLinkAboutPermit Building 2005-7-28 ~$P.l'IIN,,~laD. iii",". I, ~,a,. . ' ""- ". I -.' ! ... .. ._.0".. ,........ ~.' . . CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: COM2005-00820 ISSUED: 07/28/2005 APPLIED: 06/29/2005 EXPIRES: 01/28/2006 VALUE: $ 100,000.00 Status: Issued 225 Fifth Street, Springfield, OR .541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SITE ADDRESS: 939 HARLOW RD ASSESSOR'S PARCEL NO.: 1703223300500 Springfield TYPE OF WORK: Tenant InfilI TYPE OF USE: Alteration PROJECT DESCRIPTION: Tenant Improvements for Anethesia Services. (SUITE 200) Commercial Owner: AAA OREGON/IDAHO Address: 939 HARLOW ROAD SPRINGFIELD OR 97477 Phone Number: 541-741-8200 . - ..-. "'-. Contractor Type Architect General Electrical Mechanical Plumbing Contractor GLAS ARCHITECTURAL GROUP SUMMIT INDUSTRIES INC EUGENE ELECTRIC SERVICE INC AIR RITE CONTROL INC CASCADE PLUMBING CO I CONTRACTOR INFORM;\'f\ON.I'ALL EXPIRE IF THE WORK I nl0 r LO "..., -, I n THIS PERMIT IS NOT AUTH(I3ic;D's~INOE~xpiration iPaf~JR Phone COMMENCED OR \5 AtlANUUI~ u 541-686-2014 ANY 1 ~249\Y PERIOD, 01/25/2006 503-223-9703 90200 03/17/2007 541-344-3561 63302 12/29/2007 503-238-0388 120893 0210312007 503-544-7464 BUILDING INFORMATION I Front yard Setback: Side I Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: # of Stories: Lot Size: B Height of Structure Sq Ft 1st Floor: Type of Heat: Sq Ft 2nd Floor: VB Water Type: Sq,Ft,Basement: Range Type: Sq Ft Garage/Carport Energy Path: Sq Ft Other: Sprinkled BlliIdip!l,; oIa Occupant Load: ArTENTlnN' nrprnn I~w riPnlliriCIiC: \lnlt tn I DEVELOPMEN~iNFORM)\"'IQN~11 by the Oregon Utility "'~"!'v'{JJ, I \,,,,(,,.1,, Phose rules are REQIlIIRED PARKING in.OAR 952-001-0010 through OAR Q'T52-n01- Overlay O,l5tO' y, bt ' , f h Qfal:~ # St t T"u,," 'R oJJ may 0 am copies 0 t e !L1IP.~, ,v d ree rees Ii,f1u:h Hano. appe : Paved Driv~?R"d? t e center. (Note: the telelClrmnp'act: % of Lot c~~~1!tg~!or the Oregon Utility Notification Center is 1-800-332-2344), # of Units: Primary Occupancy Group: Secondary Occupancy Group: Primary Construction Type Secondary Construction Type: # of Bedrooms: I PUBLIC IMPROVEMENTS I Street Improvements: Storm Sewer Available: Special Instruction: Sidewalk Type: DownspoutslDrains: Notes: Pa!!e I of 4 . Status: Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection cLine I Valuation DescriDtion , Description Estimate Type of Construction Estimate $ Per Sq Ft or multiplier $1.00 Square Footage or Bid Amount 100,000.00 Total Value of Project ~ . CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: COM2005-00820 ISSUED: 07/28/2005 APPLIED: 06/29/2005 EXPIRES: 01/28/2006 VALUE: $ 100,000.00 Value Date Calculated $100,000,00 $100,000.00 06/29/2005 Fee Description Amount Paid Date Paid Receipt Number Plan Review Comm/lnd/Public $367.67 6/29/05 2200500000000000853 Plan Review Fire & Life Safety $226.26 6/29/05 2200500000000000853 -Mechanical Issuance Fe.... $10.00 7/28/05 2200500000000001005 + 10% Administrative Fee $68.57 7/28/05 2200500000000001005 + 70/0 State Surcharge $48.00 7/28/05 2200500000000001005 Building Permit $565.65 7/28/05 2200500000000001005 Fixture $56.00 7/28/05 2200500000000001005 Furnace - up to 100,000 btu $48.00 7/28/05 2200500000000001005 Gas Outlets 1-4 $4.00 7/28/05 2200500000000001005 Sanitary Sel\o'er - Improvement $292.43 7/28/05 2200500000000001005 Sanitary Sewer - Reimburs~ment $384.70 7/28/05 2200500000000001005 SDC Sanitary/Storm Admin $33.86 7/28/05 2200500000000001005 Vent Fan $12.00 7/28/05 2200500000000001005 Total Amount Paid $2,117.14 I Plan Reviews I Fire Department Review' 07/21/2005 OK 06/30/2005 Pa2e 2 of 4 GRG Plans Review: Tenant infill. Job #COM2005-00820. Occupancy Classification: B. Construction Type: V-B. Provide address and suite numbers in contrasting color from the background positioned plainly visible and legible from the street or road fronting the property (2004 Oregon Structural Specialty Code 501.2 and 2004 Springfield Fire Code 505.1). Fire extinguisher location shown on Plan Sheet A I. Will verify on location. Exit light shown on Plan Shcet AI. Will verify on location. . . CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: COM2005-00820 ISSUED: 07/28/2005 APPLIED: 06/29/2005 EXPIRES: 01128/2006 VALUE: $ 100,000.00 Status: Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Initial Review 06/30/2005 06/30/2005 APP LLH Plannin2 Review 06/30/2005 07/06/2005 APP EMM Talked to John at GLAS Architectural Group. This space is office space only for Anesthesia Group. No chemicals stored here or work on equipment, just paperwork. Public Works Review 06/30/2005 07119/2005 APP SB SDCs prepaid in 200 I. Only new fixture SDCs added. No new square footage or new paving. Structural Review 06/30/2005 07/19/2005 WE JMP See attached 6 structural comments faxed to James M. Lewis. Structural Review 07/2012005 07/20/2005 10 JMP WI. Jonathan Price faxed the response to the structural comments, Structural Review 07/22/2005 07/22/2005 APP JMP Received final internal approval. SUB Review 06/30/2005 07/13/2005 WE JF Failed lighting. Spoke to architect and he will followup on correcting plans/code forms for compliance. Pass HV AC, no building envelope issues. SUB Review 07/14/2005 07/15/2005 APP JF JMP received fax from Keith Cobun with lighting forms and layout and forwarded them to Jack Foster for his review and appronl. To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m. will be made the same wo'rking day, inspections requested after 7:00 a.m. will be made the following work day. L.~~?uired Insne<'t~ SUB Final: After all required energy inspections have been requested and approved. SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover. SUB Ceiling Grid: Interior Lighting Framing Inspection: Prior to cover and after all rough in inspections have been approved. Wall Insulation: Prior to cover. Drywall: Prior to taping. Ceiling Grid: After drywall approval but prior to cover. Final Fire Department. After all requirements of the Fire Department have been met. Final Building: After all required inspections have been requested and approved and the building is complete. Rough Plumbing: Prior to cover and including required testing. Final Plumbing:' When all plumbing work is complete. Rough Mecha,!ical: Prior to Cover Final Mechanical: When all mechanical work is complete. Pagc30f4 . . . CITY OF SPRINtJl'lJ<.LD ' 'Building/Combination Permit PERMIT NO: COM2005-00820 ISSUED: 07/28/2005 APPLIED: 06/29/2005 EXPIRES: 01128/2006 VALUE: $ 100,000.00 Status: Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Rough Electric: Prior to Cover Final Electric: When all electrical work is complete. By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information herenn is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will he made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved sel of plans will remain on the site at all times during construction. ~.( / / / Iv-. '7 2'6/0)- owner!r Conlr , Date "j Page 4 of 4 225 Fifth .street Springfield, Oregon 97477 541-~26-3759 Phone . Job/Journal Number COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 COM200S-00820 RECEIPT #: Description Sanitary Sewer - Reimbursement Sanitary Sewer - Improvement SDC Sanitary/Storm Admin ' Building Permit Furnace - up to 100,000 btu Vent Fan Gas Outlets 1-4 -Mechanical Issuance Fee- Fixture + 7% State Surcharge + ]()% Administrative Fee Payments: Type of Payment Paid By Check SUMMIT CONSTRUCTION 7/28/200S ~ ttiii,.ty of Springfield Official Receipt .velopment Services Department Public-Works Department 2200500000000001005 Date: 07/28/2005 Item Total: Check Number Authorization Received By Batch Number Number How Recei\'ed ddk 37449 In Person Payment Total: Page I of I 2:29:45PM Amount Due 384,70 292.43 33,86 S6S,6S 48,00 12,00 4,00 10.00 S6.00 48,00 68,S7 $1,523.21 Amount Paid $1,S23,21 $1,523.21