March 19, 19lJ<)
A.K, Slicklcr
36579 Alder "ranch Road
Springfield. OR 97478
RE: 6l:l66 Olat;ier. Springtield. OR - Site/Soils - W.O.1t11650
A,; you requesled. an initial silc and Subscqucnl gravel compaclion inspection were performed allhis
silC in prcpllnllion for Ihe construclion involving foundations for the proposed re.~idcnce_
" Allhe lime of lhC,inilial inspeclion approxilTllllcly 6" of 3/4" minus crushed rock had been placcd
on Ihe silC. Expansive type clay soils were evidcnt in !hc cut banks exposed at this timc. It WlL~
recommended that !his six inches be compacted and an additional 6" of cru~hed rock be installed a1
the footing areas with a minimum wid!h of 5'0" _ This wa.~ accomplished. The compaction of the
gravel surface is greater!han 95% 'Of a standard pructor. per ASTM D698-91.
.~
,,"
J hope you tlnd this repurl adequalc for you;'purposes at this time, Please conlact me if you havc
further questions, Thank you for this opportunity to be of scrvice.
l-