HomeMy WebLinkAboutPermit Building 2003-2-13
.
. CITY OF SPRINGNELD
Building/Combination Permit
PERMIT NO: COM2002-01305
ISSUED: 02/13/2003
APPLIED: 11118/2002
EXPIRES: 08/13/2003
VALUE: $ 150,000.00
Status: Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
SITE ADDRESS: 3260 GA TEW A Y ST
ASSESSOR'S PARCEL NO,: 1703222002300
Springfield TYPE OF
Restaurant
TYPE OF USE: Remodel
Commercial
PROJECT DESCRIPTION: Buffet Restaurant
Owner: DEFOE RONALD M & KARLA K
Address: 93370 HWY 99 S JUNCTION CITY OR 97448
I CONTRACfOR INFORMATION I
Contractor Type
Electrical
Role Type Null
Owner
Plumbing
Contractor
BUILDERS ELECTRIC INC
KEATING ENGINEERING
DEFOE RONALD M & KARLA K
TWIN RIVERS PLUMBING
License
4296
Expiration Date
12/10/2003
Phone
541-485-0922
541-687-8608
17695
03/11/2003
541-688-1444
BUILDING INFORMATION I
# of Buildings:
Primary Occupancy Group:
Secondary Occupancy
P"rimary Construction Type
Secondary Construction
# of Bedrooms:
# of Stories: 1 Lot Size:
Height of 15,00 Sq Ft 1st Floor:
Type of Heat: Sq Ft 2nd Floor:
Wate!:..l.ype: Sq Ft Basement:
RaR~~Ptbe:" Sq Ft Garage/Carport
.&r!~~l Sq Ft Other:
~ ~~ ~ n. ImperviourSurface Area:
~ ~ 't;~"" /"''' ~" .....1
\~~~ENT INFORMATION I *-09> ~ \)~~,o~,.
SETBACKS -* ,\~1 ~! ~0o.-S ~0I:JlOREQuiRE~'PARKING
~~'r ~~ ;'Q,,~ z,~ 0 q}" ~v;)v ~09>
Frootyard Setback: ~. ~ ~v: ~ ~i Overlay Dist: o~' ~0 ~09> ;r~otal:\~ ~0
Side 1 Setback: ~~ ~~ ~ 'S f;;;)~ ~~. # Street Trees ~0~ O'Q'\~0~-S <<,C!.\afi~~~fp.~,~
Side 2 Setback: ~~ f,) ~(() ~~"!.,~ ~~~ Paved Drive Rqd: ,",~9 o~\.fQ ,,~o ~O~~ 0c;€on:lPact:S-o
'\~ ~r;s ~"~ . ~'v z,<S 0~' ~~ ~~ ~0 ~O"
Rearyard Setback: ~'" ~~~ ~ (;J % of Lot Coverag~~ ~09> 0~ 5:l~'\ . ~ eJ:l ~0' .&~ tJ""
~~~ ~~ &~~~'~~n~
'" ..." t"- .,("\ 10,0 _5:S .0 "',.('\~ 1'00000v
'l'l IPUBLIC IMPROVEMENri'I' ...~VJ~,~C>'v0"'O~0~~<;)-
,.. 'dOv 0 0 v'U
... V' "' .~ ,,"'''(': \.'?>
',~ RJ~' &~~ide~alkifype:
d:5 ~ 0~ 0~"
v >>~D'oWhspoutslDrains
<:<
A-3
F-l
VN
VN
7,240
Street
Storm Sewer Available:
Special Instruction:
Notes:
1 of 7
Status: Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Description
Estimate
Type of Construction
Estimate
Fee Description
Plan Review CommlIndlPublic
Foundation Permit
Miscellaneous Plumbing
+ 10% Administrative Fee
+ 7% State Surcharge
Add, Alter, Extend elrc Ea Add
Building Permit
Fixture
Perm ServlFdr 401 to 600 amps
Plan Review - Planning
Plan Review Fire & Life Safety
Plan Review/Com,lnd,Pub Hourly
Sanitary Sewer - 1st 50 Feet
Sanitary Sewer - Improvement
Sanitary Sewer - Reimbursement
SDC MWMC Administration
SDC MWMC Improvement
SDe MWMC Reimbursement
SDe Sanitary/Storm Admin
SDe Transpo Admin
SDe Transpo Improvement
SDe Transpo Reimbursement
Total Amount
.
. CITY OF SPRI1~ld'u'LIJ
Building/Combination Permit
PERMIT NO: COM2002-01305
ISSUED: 02113/2003
APPLIED: 11118/2002
EXPIRES: 08/13/2003
VALUE: $ 150,000,00
I Valuation Descriotion I
$ Per SqFt
$1.00
Square Footage
150,000.00
Total Value of Project
Value
$150,000,00
$150,000,00
Date Calculated
ll/1812002
I Fees Paid I
Amount Paid
Date
11/18/02
1/17/03
1/17/03
2/13/03
2/13/03
2/13/03
2113/03
2/13/03
2/13/03
2113/03
2113/03
2113/03
2113/03
2113/03
2113/03
2113/03
2/13/03
2113/03
2113/03
2113/03
2113/03
2113/03
Receipt Number
$473,30
$68.40
$45,00
$61.90
$43,33
$105,00
$728,15
$574,00
$125,00
$55.00
$327,67
$90.00
$45.00
$1,998.01
$2,628,71
$10.00
$-67.16
$-641.94
$306,30
$3,423.11
$57,423,87
$13,014,63
2200200000000000196
1200200000000000570
1200200000000000570
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
1200200000000000689
$81,655,10
I Plan Reviews I
2 of 7
. . CITY OF SPRINGFIELD
Building/Combination Permit
""",
Status: Issued PERMIT NO: COM2002-01305
225 Fifth Street, Springfield, OR ISSUED: 02113/2003
541-726-3753 Phone APPLIED: 11118/2002
541-726-3676 Fax EXPIRES: 08/13/2003
541-726-3769 Inspection Line VALUE: $ 150,000.00
Fire Department Review 11/20/2002 12/20/2002 OK GRG Plan review of remodel from
mercantile store to Chinese
Restaurant, Change in Occupancy
from M to A-3,
Provide second exit for Meeting
Room 1 (Room 104)
Provide submittal for sprinkler
system (square footage over 5000 sq,
ft, after discounting area separated
by 1 hr, wall), (OSSC 904,2,3,1)
Provide submittals for hood and
duct fire suppression systems for all
cooking surfaces producing
grease-laden vapors,
Extend ramps to provide 1: 12 slope
(drawings show approximately 1:10
slope) (OSSC 1003,3,4,3)
Provide 2-A:I0-B:C extinguishers
every 75 feet of travel distance or
1,500 sq. ft. in area. (Springfield
Uniform Fire Code 1002,1)
Provide K-type extinguisher for
fryers (SUFC 1002.1)
Provide exit signage (OSSC
1003.2.8.)
A special investigator's report
verifying egress illumination meetin~
OSSC 1003,2,9 (not less than 1
footcandle) will be required prior to
any occupancy being granted.
Exit from kitchen through garbage
collection area not acceptable unless
gates are provided with approved
listed exiting hardware.
Provide compass points on drawings,
Fire Department Review 01/31/2003 02/03/2003 OK GRG No fire department review required
for these revisions.
Initial Review 11/20/2002 1lI20/2002 APP LLH
Planning Review 11/20/2002 1lI20/2002 DONE AJD Land Use Compatibility Statement
written-see attached doc.
Public Works Review 11/20/2002 12/10/2002 APP PJO
3 of 7
Status: Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Revised Plan Review - Fire
.
01/16/2003
01130/2003
OK
4 of 7
. CITY OF SPRIl'~u1'lELD
Building/Combination Permit
PERMIT NO: C0M2002-01305
ISSUED: 02/13/2003
APPLIED: 11/18/2002
EXPIRES: 08/13/2003
VALUE: $ 150,000.00
GRG
Plan Review: Revisions to plans
suhmitted on 12/20/02 proposal for
remodel from mercantile store to
Chiuese restaurant, Chance in
occupancy classification from M to
A-3,
Doors 104A need to swing toward
buffet area to qualify as required
2nd exit. It shall also have listed
door closing hardware. This door
shall remain closed or be provided
with listed magnetic door holders
and their appropriate listed release
detectors in accordance with NFP A
72.
Provide exit sign for Doors 104A
from inside Meeting Room I/Room
104,
Submittal for sprinkler system still
required unless wall along kitchen
dishwasher/customer
bathrooms/closet/desert bar is
provided with ODe hour fire resistive
construction (separating kitchen
from dining area to bring square
footage below 5,000 sq. ft,) unless no
alcoholic heverages will be served,
(Oregon Structural Specialty Code
904,2,3,1)
Suhmittals for commercial kitchen
hood and duct fire suppression
systems for all cooking surfaces
producing grease laden vapors are
still required. (Springfield Uniform
Fire Code 1001.3)
Ramp requirements of I: 12 slope
marked on plans and so noted.
(OSSC 1003.3,4.3)
2-A:I0-B:C extinguishers still need
to be provided for every 75 feet of
travel distance or 1,500 sq. ft, in
area, (SUFC 1002,1)
K-type extinguisher for fryers still
needs to be provided (SUFC 1002,1)
Status: Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Revised Plan Review - Pial
Revised Plan Review - Pub
Revised Plan Review - Stn
Revised Plan Review - Stn
Revised Plans ReceivedIRo
Revised Plans ReceivedIRo
Structural Review
Structural Review
Structural Review
Structural Review
SUB Review
.
01/16/2003
01/16/2003
01/16/2003
01/31/2003
1l/20/2002
1212312002
01/21/2003
0211212003
11/20/2002
01/2212002
01/2212003
01/16/2003
01/3112003
12116/2002
12/24/2002
01117/2003
0211012003
APP
WE
APP
APP
WE
10
POK
APP
5 of 7
. CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: COM2002-01305
ISSUED: 02113/2003
APPLIED: 11/18/2002
EXPIRES: 08/1312003
VALUE: $ 150,000.00
A special inspector's report verifyin~
egress illumination meeting OSSC
1003,2,9 (not less that 1 footcandle)
will still be required prior to any
occupancy being granted,
Exit from Kitchen through the
garbage collection area is still not
acceptable unless gates are provided
with approved listed exiting
hardware,
Still need to provide compass points
on drawings.
Door 107 shall have door closing
hardware. This door shall remain
closed to maintain 1 hour rating
unless provided with listed magnetic
door holders and their appropriate
listed release detectors in accordanct:
with NFPA 72,
Door 106A shall be relocated away
from door 107,
EMM
TR
See Attached Documents, Plan
review letter faxed to Steve Keating
1/22/03 -Ih
LLH
LLH
TR
See Attached Documents for Plan
Review Letter. Add Fire and Life
Safety Plan Review fee per Tom
Rogers. Faxed letter to Steve
Keating 12116/02
PLANS (not forms) of Energy Code
Compliance lighting diagrams from
Builders electric fed ex'd to Tom
Rogers - Ih
OK to issue foundation permit only.
Review not complete on remainder
of building,
LLH
TR
TR
Don Moore requested Steve Keating
to.provide energy forms to City for
plan review as soon as possible,
_111- ,a.,....,.N,'.....".'~...,.......".,""i
:::::~~rr~,.,'.
",,-, ,.
'"".:; :~. ,.
',..
._" "...- ._" ';""'. >\!'
.
. CITY OF SPRINGFIELD
BuildinglCombinationPermit
PERMIT NO: COM2002-01305
ISSUED: 02/1312003
APPLIED: 11/1812002
EXPIRFS: 08/13/2003
VALUE: $ 150,000.00
Status: Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
SUB Review 12123/2002 12124/2002 10 LLH PLANS (not forms) of energy code
compliance lighting sent to Jack
Foster - Ih
SUB Review 02/10/2003 12131/2003 POK JF Pass Lighting energy code, Bldg.
envelope and HV AC forms still not
received.
SUB Review 02/ll/2003 0211112003 OK JF CONDITIONAL APPROVAL-
Building envelope OK. HV AC
system not yet approved. OK to
issue permits provided the Code
compliance forms for HV AC system
to be submitted prior to
modifications to the system.
To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a,m.
will be made the same working day, inspections requested after 7:00 a.m. will be made the following work
day.
l...}leouirerlJnsnections I
1 Footing: After trenches are excavated,
2 Foundation: After forms are erected but prior to concrete placement,
3 Bolts Installed in Concrete: To be done by a State Certified Special Inspector. Provide inspection test reports to
City Building Inspector,
4 UnderOoor Plumbing: Prior to insulation or decking,
5 Epoxy Anchors: To be done by Certified Spcial Inspector, Provide Inspection results to City Building Inspector,
6 Framing Inspection: Prior to cover and after all rough in inspections have been approved.
7 Roofing: Prior to installing any roof covering,
8 Drywall: Prior to taping.
9 Firewall: Located and constructed according to plans.
10 Structural Masonry: To be done during construction by a State Certified Special Inspector. Provide results to
City Building Inspector,
11 Final Fire Department, After all requirements of the Fire Department have been met.
12 Final Building: After all Conditions have been completed as required on Development Agreement,
13 Final Building: After all required inspections have been requested and approved and the building is complete.
14 SUB Insulation Vapor Barrier: To be called for at the same time as tbe SUB framing inspection.
IS SUB Final: After all required energy inspections have been requested and approved.
16 UnderOoor Plumbing: Prior to insulation or decking,
17 Rough Plumbing: Prior to cover and including required testing.
18 Water Line: Prior to filling trench and including required testing,
19 Sanitary Sewer Line: Prior to filling trench and including required testing,
20 Final Plumbing: When all plumbing work is complete,
21 Rough Electric: Prior to Cover
22 Electric Service: Approval required prior to utility company energizing service.
23 Final Electric: When all electrical work is complete,
24 Underground Electric: Prior to cover
6 of 7
Status: Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
.
.
CITY OF SPKli'I\.J~IELD
Building/Combination Permit
PERMIT NO: C0M2002-01305
ISSUED: 02113/2003
APPLIED: 11/18/2002
EXPIRES: 08/13/2003
VALUE: $ 150,000.00
By signature, 1 state and agree, that I have carefuUy examined the completed application and do hereby certifY that all
information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance
with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described
herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division,
Building Safety. I further certifY that only contractors and employees who are in compliance with ORS 701.005 wiD be
used on this project.
I further agree to ensure 11 required inspections are requested at the proper time, that each address is readable from
the street, that the mit ca d is located at the front of the property, and the approved set of plans will remain on the site
at all times du' cons tion,
/i2 __ n _=-=- .
O;':;r or COD?cro~gDatur0
7 of 7
<7 / I ~ {h 5
Date
225 Fifth Street
Springfield, Oregon 97477
541-726-3759 Phone
Line Items:
Job/Journal Number
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-01305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002.0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
2113f2003
9:45:17AM
City of Springfield
Development Services Department
Public Works Department
Official Receipt
Receipt #: 1200200000000000689
Date: 02113/2003
.
Amount Paid
55.00
2,628.71
1,998.01
10.00
(67,16)
(641.94)
13,014.63
57,423.87 .
(3,461.04)
(15,271.00)
17,890.22
1,063.85
327.67
306.30
3,423.11
Description
Plan Review - Planning
Sanitary Sewer - Reimbursement
Sanitary Sewer - Improvement
SDC MWMC Administration
SDC MWMC Improvement
SDC MWMC Reimbursement
SDC Transpo Reimbursement
SDC Transpo Improvement
SDC Transpo Reimbursement
SDC Transpo Improvement
SDC MWMC Reimbursement
SDC MWMC Improvement
Plan Review Fire & Life Safety
SDC Sanitary/Storm Admin
SDC Transpo Admin
Page I of3
cReceipt.rpt
225 Fifth Street
Springfield, Oregon 97477
541-726-3759 Phone
COM2002-0 1305
COM2002-01305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-0 1305
COM2002-01305
Receipt #: 1200200000000000689
Date: 02113/2003
Sanitary Sewer - 1st 50 Feet
Fixture
+ 7% State Surcharge
+ 10% Administrative Fee
Plan Review Fire & Life Safety
Plan Review/Com,lnd,Pub Hourly
Building Permit
+ 7% State Surcharge
+ 10% Administrative Fee
+ 7% State Surcharge
+ 10% Administrative Fee
Perm Serv/Fdr 40 I to 600 amps
Add, Alter, Extend Circ Ea Add
Page 2 of3
2/13/2003
9:45:17AM'
City of Springfield
Development Services Department
Public Works Department
Official Receipt
45.00
.
574.00
43.33
61.90
327.67
90.00
728.15
94.30
134.72
16.10
.
23.00
125.00
105.00
Line Item Total:
$81,068,40
cReceiptrpt
225 Fifth Street
Springfield, Oregon 97477
541-726-3759 Phone
Payments:
TWe of Payment
Check
Receipt #: 1200200000000000689
Date: 02/13/2003
Paid By
Received By
Check Nnmber Confirm No
CHINA SUN BUFFET OF
OREGON
djb
Page 3 of3
2/13/2003
9:45:17AM
City of Springfield
Development Services Department
Public Works Department
Official Receipt
.
....... How Received
Amount Paid
In Person
81,068.40
Pavment Total:
$81,068.40
.
cRoceiptrpl