HomeMy WebLinkAboutPermit Field Test & Inspection Report 1997-6-30
'A;ug-O.l--97
12:58P M~Jlter Eng;neer;ng
141 )484-6859
P_U2
f',O. BOX 139 . 1245 PEARL STREET
EUGENE. OnEGON 91440
PHONE (541) 484.9080 . FAX (541) 484.6859
/-~\t ..j' i;-"
/,\.IIoI\f.tMrl."", "'i\
/ -:< ~;i.'#:-' ~ ' ? .~.\
tr,. j, 1:'1 :1 ...1 \
~ . Ill' I-I '[ ,j
'l-i: IIJ.~..... J~"'--YJ
10.\). '.~,~\./,
'J'I'\'I:\'~;";
:-"'~..:_-_:....;..~'"
STRUCTURAL
BUilDING DESIGN. FIRE PROTECTION
CODE CONSULTANT. PLAN CHECKING
CONSTRUcnON INSPECTION
~ORTIER
I:.NGINEERING, P.c.
July 30, 1997
Phil Lindley
S81S Aster
Springfield, OR 97478
IiE:6831H6ii;S;;-rinllfie'td OR"": Excavation & Fill InsDection - W.O. #10160-RDR
As you requested, an inspection has been made during the performan.;t: of the excavation and
placement of gravel fill on this site in preparation for construction involving foundations for the
propo!llX! residenre. The excavation involved the removal of surface organic soil and other unsuitable
material and the placement of 12" maximum Df J 'h" minus crushed rock in accordance with our
standard procedures. The compacted surface of the crus.'1ed rock is adequate to support the proposed
wllventional wood frame residence. The compaction of the gravel surface is greater than 95% of a
standard proctor per ASTM D698-9 I.
.
I hope this report is adquate for your needs and purposes at this time. Thank you for this opportunity
to be of service. If you have furthcr questions. please contact me at 484-9080.
Very truly yours.
-
Owen Grover, P.E.
.
OLG\bjr
genCOf.~Iharh\t:a.c.avfil.rdr