HomeMy WebLinkAboutPermit Field Test & Inspection Report 1997-6-30 'A;ug-O.l--97 12:58P M~Jlter Eng;neer;ng 141 )484-6859 P_U2 f',O. BOX 139 . 1245 PEARL STREET EUGENE. OnEGON 91440 PHONE (541) 484.9080 . FAX (541) 484.6859 /-~\t ..j' i;-" /,\.IIoI\f.tMrl."", "'i\ / -:< ~;i.'#:-' ~ ' ? .~.\ tr,. j, 1:'1 :1 ...1 \ ~ . Ill' I-I '[ ,j 'l-i: IIJ.~..... J~"'--YJ 10.\). '.~,~\./, 'J'I'\'I:\'~;"; :-"'~..:_-_:....;..~'" STRUCTURAL BUilDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUcnON INSPECTION ~ORTIER I:.NGINEERING, P.c. July 30, 1997 Phil Lindley S81S Aster Springfield, OR 97478 IiE:6831H6ii;S;;-rinllfie'td OR"": Excavation & Fill InsDection - W.O. #10160-RDR As you requested, an inspection has been made during the performan.;t: of the excavation and placement of gravel fill on this site in preparation for construction involving foundations for the propo!llX! residenre. The excavation involved the removal of surface organic soil and other unsuitable material and the placement of 12" maximum Df J 'h" minus crushed rock in accordance with our standard procedures. The compacted surface of the crus.'1ed rock is adequate to support the proposed wllventional wood frame residence. The compaction of the gravel surface is greater than 95% of a standard proctor per ASTM D698-9 I. . I hope this report is adquate for your needs and purposes at this time. Thank you for this opportunity to be of service. If you have furthcr questions. please contact me at 484-9080. Very truly yours. - Owen Grover, P.E. . OLG\bjr genCOf.~Iharh\t:a.c.avfil.rdr