Loading...
HomeMy WebLinkAboutPermit Building 1996-4-9 SPRINGFIELD ~- Page 1 COMMERCIAL/INDUSTRIAL PERMIT APPLICATION CITY OF SPRINGFIELD Job Number: 960223 COMMUNITY SERVICES DIVISION BUILDING SAFETY 225 North Fifth Street Springfield, OR 97477 Office: 726-3759 Inspection Line: 726-3769 Location of Proposed Work: 3443 HUTTON WAY Assessors Map #: 17032220 Tax Lot #: 00803 Owner: SYCAN B CORP Address: 3405 BALDY VIEW LANE Phone #: 746-8444 City/State/Zip: SPRINGFIELD, OREGON 97477 Description Of Work: MARIOTT MOTEL NEW Value: 3,800.00 Name Architect: GREG ALLWITE Address Phone 206-431.7960 Contractor Canst. Contractor # Expires Phone General: MEGA PACIFIC PO Box 82186 Portland AMERICAN HEATIN 1339 SE Gideon Street 0063108 OR 972820186 0033135 Portland OR 9 01/16/97 238-3772 Mechanical: 06/18/96 239-4600 PLUMBING NO, 438 Fee Charge 4,380,00 85,00 55,00 490,00 20.00 55,00 Single Fixture Sanitary Sewer Water Service Storm Sewer 2 BACKFLOW DEVICES 183' FIRE LINE 362 186 3085 ft, ft, ft. TOTAL PERMIT 5,085.00 --- MECHANICAL --- No, Fee Charge 60.00 9,00 438,00 18,00 33.00 60.00 14,50 10,00 146 Furnace/burner & vent < 1000,000 BTUs Mechanical exhaust hood and duct Vent Fan/Single Duct 3 AC UNITS 11 APPLIANCE VENTS 10 HP UNITS VENT SYSTEM & GAS Permit Issuance TOTAL PERMIT 642,50 HANDICAP ACCESS: Y # OF UNITS: 116 -- OFFICE USE QUAD AREA: lCNW ZONING CODE: CC LAND USE: 5300 Item Square Feet x $/Square Feet = Value SPRINGFIELD /~I'~ Job Number: 960223 Page 2 Sq, Ftg Main 60466 3,019,000.00 TOTAL VALUE OF PROJECT 3,019,000,00 Plan Check Fee: 5,319.00 Rec #: 20428 Date: 02/20/96 Rec By: DON MOORE BUILDING Surcharge/Admin MECHANICAL Surcharge/Admin PAVING VALUE PLUMBING Surcharge/Admin FENCE VALUE SIDEWALK CURBCUT PLAN REVIEW OVERPAY 2,970,00 5,111,50 408,93 642,50 50,61 691,75 5,085,00 406,80 5,00 54.55 15.55 -1,996,53 214,000,00 SUBTOTAL PERMITS SYSTEMS DEVELOPMENT ...v~ -:Z~I t:>5"?" 6 ~ "'* 7Y2.a9 111,27~ ..1., ap#;JY~~~2tl;; REQUIRED INSPECTIONS 10,475,66 100,802,~-i" TOTAL PERMIT FEES EXCLUDING ELECTRICAL It is the responsibility of the permit holder to see that all inspections are made at the proper time, To request an inspection, call 726-3769 (recorder), state your City designated job number, job address, type of inspection requested and when you will be ready for inspection. Requests received before 7:00 a.m. will be made the same working day, requests made after 7:00 a,m will be made the following work day, Special Inspections: In accordance with a special inspector shall be employed by construction of any following 11*11 work. shall be furnished to Building Safety, Section 306 of the State Specialty Code the Owner/Contractor during A copy of the special testing reports In addition to the inspections specified, the Building Official may make or require other inspections of any construction work to ensure compliance with the Building, City or Development Code. TEMPORARY POWER UNDERGROUND ELECTRICAL - Prior to Cover, UNDERGROUND PLUMBING - Prior to filling trench. FOOTING - After trenches are excavated, FOUNDATION - After forms are erected but prior to concrete placement, SLAB - To be made after all inslab building service equipment, conduit piping, and other equipment items are in place but prior to concrete ROUGH PLUMBING. Prior to cover, ROUGH MECHANICAL - Prior to cover. ROUGH ELECTRICAL - Prior to cover, ELECTRICAL SERVICE - Must be approved to obtain permanent power. FRAMING - Prior to cover. INSULATION - Floor; prior to decking Wall/Ceiling; Prior to cover SPRINGPIELD ~. Job Number: 960223 Page 3 DRYWALL - Prior to taping, CURB CUT - After forms are erected but prior to placement of concrete. SIDEWALK - After excavation is complete, forms and sub-base material in place, ROUGH GRADING - After gravel is in place but prior to placing concrete FINAL PLUMBING - When all plumbing work is complete, FINAL MECHANICAL - When all mechanical work is complete, FINAL ELECTRICAL. When all electrical work is complete, FINAL FIRE - When all Fire Department requirements have been met, been met, CONC SLAB/SUB: PRIOR TO/FOLLOWING POUR INSUL-V,B,/SUB: TO BE CALLED FOR AT SAME TIME AS SUB FRAMING INSPECT MECH/SUB: FOLLOWING ROUGH MECHANICAL APPROVAL, PRIOR TO COVER FINAL/SUB FINAL SITE PLAN - After all requirements have been met for Minimum Development Standards or from the Development Agreement, FINAL BUILDING - When all required inspections have been approved and the building is complete, --- ADDITIONAL COMMENTS --- DRC #95-11-209, PLANNER IS LAUREN LEZELL SITE PLAN REVIEW JOURNAL #95'11-209, LAUREN LEZELL Plans Reviewed By: LORNE PLEGER Building Site Reviewed By: LISA HOPPER Date: 04/03/96 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety, I further certify that only contractors and employees who are in compliance with ORS 701,055 will be used on this project, I further agree to ensure that all required inspections are requested at the proper time, that project address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction, tAr'l~ ~~ H~ I Lf -Cf'-C(1tJ Date --- VALIDATION Date Paid: ~ jc//? 7"'~~b -;z?; .::;'~5': :2b ; . -~~ Receipt Number: Amount Received: Received By: CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE (COMMERCIAL / INDUSTRIAL) Name or Company: SYCAN B CORP Location: 3443 HUTTON WAY Developement Type: C Building Size: Job No,: 960223 Lot Size: 1. STORM DRAINAGE Impervious Sq Ft 1,0 X 94606 Page 1 Sq Ft 0,210 Per Sq Ft $19,867,26 .3Jt~ /~#- ~ 'U7.1I. X 2. SANITARY SEWER Number Of PFUs (see Page 2) - CITY l.0 X 892 X 43,43 Per PFU 3. TRANSPORTATION Number Of Units 1,0 X 116 X X Trip Rate 0,420 X X Cost Per Trip 437,93 $21,335,95 Transportation Total 4. SANITARY SEWER - MWMC Number Of PFUs 892 X X Per PFU + MWMC Admin Fee 18,750 + 10,00 MWMC CREDIT If Applicable (see Page 2) TOTAL - MWMC SDC SUBTOTAL - (Add Items 1, 2, 3 & 4) 5. ADMINISTRATIVE FEES Base Charge (Subtotal Above) X 0.50 TOTAL SDC ;::"'~#t-M' Reviewed By: TROY MCALLISTER t/E"~~ Date: 04/03/96 $38,739, 56 -p~ $21,335,95~ $16,735,00 $675.40 $16,059, 60 ~;t11r /Y~ $96,002.37 $4,800,12~~~ $100,802.49 ~~"~c 7~7y.:?_? Job Number: 960223 FIXTURE UNIT CALCULATION TABLE Fixture Type Bathtub Drinking Fountain Floor Drain Interceptors For Grease/Oil/Solids/Etc Inteceptors For Sand/Auto Wash/Etc Laundry Tub/Clotheswasher Clotheswasher . 3 Or More Receptor For Refrigerator/Water Station/Etc Receptor for Commercial Sink/Dishwasher/Etc Shower, Single Stall Shower, Gang Sink, Bar, Commercial, Residential Kitchen Urinal, Stall/Wall Wash Basin/Lavatory, Single Water Closet, Public Installation Water Closet, Private Miscellaneous TOTAL FIXTURE UNITS Number of New Fixture o o o o o o o o o o o o o o o o o Page 2 Unit Fixture Equivalent Units 2 0 1 0 2 0 3 0 6 0 2 0 6 0 1 0 3 0 2 0 0 . 2 0 2 0 1 0 6 0 4 0 0 0 CREDIT CALCULATION TABLE: Based on assessed value. If improvements occured after annexation date, credits are calculated separately. (calculations are by $1000) Year Annexed: 1969 Credit For Parcel Or Land Only If Applicable: Improvement (if after annexation date) : 194,640 X 3,47 675,40 o X 3,47 0.00 CREDIT TOTAL = $675.40 (If land value is multiplied by 1 then the parcel/land credit is not accurate,)