March 17, 1994
~~st--It.. brand fax transmittal m:mo 7671 J'OIP'9~" -L~:~~
To s:.-\., 11,__ 'tPh,.d--S/\ ,.om M.o.c.h.f'C..f ;'J'
~. Co. - ' 0..____
Building Permit services
city of Springfield
225 N. 5th
Springfield, OR 97477
I Dept.
IFull
Phone II
.JLf4__~jL, ( ~)_.__._
Fax II
/ ,
RE: GZ264. Hollv. Williams General Contractiug - W.O. #6956
The substitution of (2) simpson MAS or (1) Simpson MA6 at 24" o.c. ill
lieu of 5/8" diameter anchor bolts is acceptable on this project, I.1
addi tion, the use of Simpson H2. 5 in lieu of Simpson A34 at plate to
joist connection is acceptable on this project.
The contractor has beEm informed that any deviation fro
specifications in future projects is to be brought to the attention of
the engineer for approval prior to any change.
I hope you find this report adequate for your purposes at this tilne.
please contact me if you have further questions. Thank you for this
opportunity to be of service.