Loading...
HomeMy WebLinkAboutPermit Building 2001-9-14 ,.. .\ 225 North Fifth Street Springfield, OR 97477 . - Page 1 of 4 TRANS~:01-0006703 DATE:SEP 14 2001 AMT RECD:2 $ 129.00 CHANGE: CASHIER:062 I Job# 01-00631-01 I CITY OF SPRINGFIELD, OREGON RESIDENTIAL PERMIT City Of Springfield Community Services Division Building Safety Job Number: 01-00631-01 Office: 726-3759 Inspection Line: 726-3769 Location Of Proposed Site: 4662 Holden Ct Spr Assessors Map#: 00000000 Lot: 15 Block: Addition: Owner: Address: Tax Lot #: 00000 Subdivision:Marvin Manor Marvin Margolis 2050 W 25th Phone Number: 541-686-2525 City/State/Zip: Eugene, OR 97405 New Value: $148,574 Scope Of Work: Single Family Residence Contractor Type General contr Electrical Contr Mechanical Contr Plumbing Contr Quad Area: # Of Units: Constr. Type: Water Heater: Contractor Larry Cooper 2955 Timberline, Eugene, OR 97405 Deans Electric P.O. Box 2585, Eugene, OR Deans Electric P.O. Box 2585, Eugene, OR Master Plumbing Service PO BOX 150, Sutherlin, OR 97479 Registration # Expiration Date Phone 541-302-5852 38195 10/1/01 541-935-5303 38195 10/1/01 541-935-5303 142776 5/5/02 541-459-6552 3RSC 1 (VN) Wood Frame Office Use Land Use: Zoning Code: LDR Bedrooms: 3 Range: # Of Buildings: 1 Occupancy Group: Dwelling Heat Source: Sq. Footage: 1986 To request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following working day. Site Verify Ground Rod Footing Foundation Post and Beam Floor Insulation Ceiling Insulation Shear Wall Nailing Framing Required Inspections I Buildin!l I - To be made after excavation but prior to setting forms. -Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation i -After trenches are excavated. -After forms are erected but prior to concrete placement. -Prior to floor insulation or decking. - Prior to decking. - Prior to cover. - Before covering sheathing with finish materials. - Prior to cover. ,r-" \ Wall Insulation Drywall Hold Downs Installed Final Building Temporary Power Verify Ground Rod Rough Electrical Electrical Service Final Electrical Underfloor Plumbing Underfloor Drain Rough Plumbing Water Line Sanitary Sewer Line Storm Sewer Line Final Plumbing Underfloor Mechanical Rough Mechanical Final Mechanical . I Job# 01-00631-01 I Required Inspections Building . - Prior to Cover - Prior to taping. Page 2 of 4 - When all required inspections have been approved and the building is complete. I Electrical I -Approval required prior to SUB energizing pole. -Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation i - Prior to cover. -Must be approved to obtain permanent power. -When all electrical work is complete. I Plumbing -Prior to insulation or decking. - Prior to cover or placement of concrete. - Prior to cover. - Prior to filling trench. - Prior to filling trench. - Prior to filling trench. - When all plumbing work is complete. I Mechanical - Prior to insulation or decking. - Prior to cover. - When all mechanical work is complete. 00/00/00 00:00 AM USE EXISTING CURB CUT Sidewalk Type: Additional ROW? Size Of Line (in): Downspouts/Drains: Enchroachment Permit: San Sewer Tee (in): Bond End DateTime: Street Improvement: Fully Improved Curb Cut?D Improvement Agr.?D San Sewer Depth (Ft): 6 4 Storm Sewer Available? 0 Special Req.: Security Required: Bond Begin OateTime: Special Instructions: Other Utilities: Project Supervisor: Curbside - 5' o 8 To Curb and Gutter 6 00/00/00 00:00 AM Types Of Warning Devices Reqd. .;--. . I Job# 01-00631-01 Overlay District: # of Street Trees: . Zoning: LDR FloodPlain? 0 Wetlands? 0 Journal numbers 1: 99-09-0248 2: Comments~im Donovan - Planner for Subdivision 3: Additional Requirements: Required Attachments: Source Locn: Material: Planner: Liz Miller Urban Growth Boundary?D Glenwood Area? 0 Quantity Of Fill: Supplier: Drainage: Floodway FEMA: Zone X white Construction Types:(VN) Wood Frame Occupancy Groups:Dwelling # Of BUildings: 1 # Of Bedrooms: 3 Handicap Access? 0 iArea (Sq. Feet) I Main: 1986 Accessory560 Fee Residential Plan Check Total Plan Check Building Permit State Surcharge For Building Permit Building Administrative Fee Total Building Wiring Footage 1,000 Sq Ft or Less Wiring Footage Each Add'l 500 Sq Ft Temporary: 200 Amps or Less State Surcharge - Electrical Administrative Fee - Electrical Total Electrical Minimum Plumbing Permit Fee Minimum Plumbing Permit Fee Three Bathrooms State Surcharge - Plumbing State Surcharge - Plumbing Storm Sewer Footage Administrative Fee - Plumbing Administrative Fee - Plumbing Total Plumbing Hood and Exhaust Minimum Mechanical Permit Administrative Fee - Mechanical Page 3 of 4 Land Use: Pave Driveway? 0 Flood Plain FEMA: Panel 1162 of 2975 # Of Stories: 2 Height (feet): 25 Current Units: Proposed Units:1 Census Code: New SF - detached Total:2546 Paid On Receipt# Plan Check 06/20/2001 5896 Building 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 L Electrical 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 Plumbing 07/10/2001 6108 09/14/2001 6703 07/10/2001 6108 07/10/2001 6108 09/14/2001 6703 09/14/2001 6703 07/10/2001 6108 09/14/2001 6703 Mechanical 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 Value/Quantity 148,574 148,574 1 4 1 1 66 1 Fee Amount $353.11 $353.11 $543.25 $38.03 $16.30 $597.58 $85.00 $60.00 $40.00 $12.95 $5.55 $203.50 $.00 $.00 $192.50 $13.48 $2.80 $40.00 $5.78 $1.20 $255.76 $4.50 $.00 $.77 VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. NO PORTION OF STRCTURE INCLUDING ROOF EAVES OR BUILDING FOOTINGS MAY ENCROACH INTO EASEMENT .,...... . Page 4 of4 . Job# 01-00631-01 Fee Paid On Receipt# Mechanical 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 Value/Quantity Less than 100,000 BTU Vent Fan to One Duct Dryer Vent Mechanical Issuance State Surcharge - Mechanical Total Mechanical 1 4 1 New Sidewalk Encroachment Permit - Residential Total Public Works Public Works 07/10/2001 6108 09/14/2001 6703 40 1 Residential - Single Family - Storm Sanitary Sewer Residential Transportation Residential Improvement MWMC MWMC Administrative Fee Sanitary Sewer SDC Reimbursement SDC Administrative Fee Residential Sanitary MWMC Transportation SDc Reimbursement Total System Development System Development 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 07/10/2001 6108 1 1 2,042 24 1 1 1 24 S.F. Residence - Willamalane Total Willamalane SDC Grand Total Willamalane SDC 07/10/2001 6108 1 Plan Check Type Checked By Date Completed Comment Initial Review-Res Bob Barnhart Steve Templin 06/21/2001 06/27/2001 Engineering-Res Planning-Res Structural-Res Liz Miller 07/03/2001 07/03/2001 Don Moore Fee Amount $6.00 $12.00 $3.00 $10.00 $1.79 $38.06 $65.00 $85.00 $150.00 $553.38 $387.60 $656.02 $24.33 $10.00 $510.00 $129.08 $285.91 $154.27 $2,710.59 $1,000.00 $1,000.00 $5,308.60 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the seat all times during construction. n L "S; OJ- /(..1- V/ \ '1r\ Al.}fXAlL. I Signature Date