HomeMy WebLinkAboutOccupancy Correspondence 1992-3-17 DEVELOPMENT SERVICES PUBUC WORKS METROPOLITAN WASTEWATER MANAGEMENT 225 FIFTH St.'iEET . SPRINGFIELD, OR 9i-: i7 ' (503) 726.3753 ~larch 17, 1992 CERTIFIED LETTER ~lanson Jackson 27939 Royal Avenue Eugene, OR 97402 I, Subject: Housing Inspection at 2158 Laura Stree~ Springfield, Oregon. Dear Mr, Jackson: -- - . .. At your request, the Springfield Building Safety Division conducted a Housing Inspection at'the above address. The inspection revealed items which do not meet the minimum City Housing Code requirements and must be corrected. They consist of the following: Structural 1, Dryrot is evident in the bathroom which requires repair or replacement. 2. Deterioration requiring repair or replacement is evident in the roof covering creating a potential for weather infiltration and damage to the interior. Electrical 3. The electrical service located at the rear of the structure is an interior panel and not approved to be located on the exterior of a structure where it is subject to wet or damp conditions. An exterior rated panel, sized and grounded in accordance with the current code requirements shall be installed, 4, The electrical wall heater located in the utility room shall be relocated or removed because of the potential fire hazard resulting from it's location to combustible material. . 5. It appears that the existing electrical system has not been updated in a manner to accomodate the increase in loading and safety of today's electrical uses. Although not speCifically required by the minimum standards of the current Housing Code, the following electrical safety irnp)'o\-emen~s al-e st.rongl~- encoul-aged: ~". . . e Nanson Jackson ~Iarch 17, 1992 Page 2 A, Provide two 20 ANP appliance circuits in the kitchen/dining area. Such curcuits, whether two or more are used, shall have no other outlets or fixtures extended from them, Those outlets located within six feet of the kitchen sink shall be GFCI protected. B, A GFCI protected bathroom receptable be installed. C. A 20 AMP laundry receptacle and a 30 ANP dryer outlet be installed; both of which will have no other outlets. , ( D. A branch circuit and a range outlet of at least 30 ANP, 240 volt rating be installed. 6. Electrical installations, alterations or modifications shall conform to _______ _. __present Ele_ct.r:.!f.C!..L S~,e_ci'!.l t}.'.... SaJetY~.f,?de_Je.9!:l_i.!"~..'!l.E!.n!~-,--. ___,_~_~,__ __ __,____ Plumbing 7. The unused septic tank shall be pumped and filled with earth, sand, gravel, concrete or other approved material, Building permits must be obtained for the above items which involve repairs or modifications to the structural, electrical, plumbing or mechanical systems of the building and for any additions or revisions you wish to make to the building. A licensed electrical contractor is required for all new work and alterations to existing electrical systems in structures which are for sale, lease or rent. However, the replacement of parts for electrical devices which is necessary for maintenance of approved existing electrical installation~ may be done by the owner of the property, If you need any further information or have 'any questions regarding the above requirements, please contact the appropriate inspector noted below between the hours of 8:00-9:00 a.m,; 1:00-2:00 p.m" or 4:00-4:30 p.m, at 726-3759, 3:' fJ~ Tom Narx Building Inspector -!:,~u Electrical Inspector cc: Dave Puent, Building Official . ~.~ SENDER: . Complete items 1 and/or 2 for additional services. . Complete items 3. end 48 & b. . Print your name and address on the reverse of this form so that we can return this card to you. . Attach this form to the front of the mailpiece, or on the back if spece dOGS not permit. . Write "Return Receipt Requested" on the mail piece below the article number . The Return Receipt Fee will provide you the signature of the person deliverec to and the date of deliverv. _ - 3. Article Addressed to: YO 1Y\0vv--.~Y"\ 3o..cK.&>n ~J q?:.C) ':i<o't\oi Cl,v..Q. 1.M.~, 0<< qj,-/O:> _ ?;t~\~~1 5. Signature (Addres@P'e) 6. Signature (Agent) ,0"",'. ;:;).IS9 LruA'~' I also wish to receive the following services (for an extra fee): 1. ~Addressee's Address 2. 0 Restricted Delivery Consult postmaster for fee. 148. AQ!.cle NUrTJber , -\--' {~nnCj 1--3/ 4b. Servic11\D- o Registered 0 Insured ~ Certified 0 COD o Express Mail 0 Return Receipt for Merchandise. 7'~Z;.h~liVjq,_ f d- 8. Ad-dressee'! Addred (Only if requested and fee is paid) , ,', . ~::" Ps Form 3811, November 1990 'A'U.S.GPO:1991-287.()66 DOMESTIC RETURN RECEIPJ UNtTED STATES POSTAL SERVtCE Official Business ~ .. PENAL TV FOR PRIVATE USE, $300 Print your name, address and ZIP Code here . . , -.._............l ....' -- -,- :~ :;.,'--'f.~_~';. 'If;,'-;(r(if~ lJ'C::-""'" L~U' DE\''::LOPMENT SERVICES 225 FIFTH STREET SPRINGF:ELD. OR 97477 ~IS?1 ~CU, P 676 009 631 ~ Certified Mail Receipt No Insurance Coverage Provided ... Do not use for International Mail ,.~m\~'~ (See Reverse) 1 Senl 10 )\\~c:....cl'" '\n.rK,'o'-" Street & No. r:-\ ^ _ ~/C)~ q <l-<'a...k",!I ft'v.IL. Pq:la:';::':-; oRU C17l/0:J_ ~.. $ .;lC] 1.00 I I ~ P I~ lJ' Xl I Certified Fee I Special Delivery Fee I Restricted Delivery Fee Return Receipt Showing to Whom & Date Delivered o 0> s:.:. Refurn Receipt ShOwing to Whom, ~ Date, & Address of Delivery '_00 -'; TOTAL ""lage .-.ct '" ,Q o &FGes ~ ~OlN~ .e;;.I~1 iiii ""'n"''''O'6'''~ ~. -1;-1:-' M 1'':'''' _ 'p). E C::--I'~"ll & ~\~ --.I;;: ;;; ~I O~ ~/c. f STtCK POSTAGE STAMPS TO ARTtClE TO COVER FtRST CLASS POSTAGE, CERTIFtEO MAil FEE, AND CHARGES FOR ANY SELECTED OPTtONAl SERVtCES (se. lront). 1. If you want this receipt postmarked, stick the gummed stub to the" right of the relurn address leaving the receipt attached and present the article at a post oHice service window or hand it 10 your rural carrier (no extra charge). , 4. II you wint delivery restricted 10 the addressee, or 10 an authorized agent of the addressee, endorse RESTRICTED DELIVERY on the front of the article. . ~ a;- f! l o 0> ~ " c: => ...., o o CD .., E ,f en a. 2. If you do not want this receipt postmarked, stick the gummed st~b to the right of the return address of the article, date, detach and retain the receipt, and,mail tne article. 3. If you want aretum receipt, write the certified mail number and ;Our name and address on a return receipt card. Form 3811. and attach it to the front of the article by means of the gummed ends ifspace'perrnils. Otherwise. affIX to the back of article. Endorse front of article RETURN RECEIPT-REQUESTED adjacent 10 the number. . 5. Enter lees for the services requested in the appropriate spaces on the front. of this receipt. If return receipt is requested, check the applicable blocks in item 1 of Form 3811~ 6. Save this receipt and present it if you make inquiry. -c:U.S.G.P.O.1990-270.153