Loading...
HomeMy WebLinkAboutPermit Miscellaneous 1990-3-28 .-, - CITY OF SPRINGFIELD Development Services Department DATE OF Lt..."",, March 28, 1990 APPLICANT Mr. John Hyland Hyland Construction, Inc. 1941 Laura Street Springfield, OR 97477 SUBJECT CITY JOURNAL NUMBER 90-03-45. Type I Site Plan requesting approval to store construction materials, construction equipment, cats, cranes, track hoes, and office trailers. Vehicula~t~at~ic~~ll be limited to once or twice a week. The property is located a tllf6'46~Mai~,e~fY (Assessor's Map 17-02-32-42; Tax Lots 200 and 300). The property i~zoned Light Medium Industrial (LMI); the East Main Refinement Plan' designation is Light Medium Industrial. The storage use is permitted in the LMI District. ACTION PRELIMINARY SITE PLAN APPROVAL. WAT NEEDS TO BE DONE TO OBTAIN FINAL SITE PLAN APPROVAL? 1. A Final Site Plan, drawn to scale is required within 90 days of the date of this letter. The following information needs to be shown: a. Outside storage of materials must be screened by a sight obscuring fence. The entire site, not just that portion along the frontage of Man Street needs to be slatted (Ref. SDC 20.090(1)(d)). In addition, a gate needs to be placed in the north'fence and gravel from the fence line to the yard area for access to the fire hydrant north of the property between lots 200 and 300. b. A 7 foot-wide sidewalk is required along the frontage of the entire Since the right-of-way width in this area aJlows for only a 6 1/2 sidewalk, a 10 foot-wide sidewalk and utility easement will be property. foot-wide required. Contact Cynthia Pappas of this office at 726-3759 to see if you qualify for the Minimum Development Standards Grant Program. c. There are two driveways proposed for this development. The maximum width for a curb cut is 35 feet with 8 foot flares. ' The dimensions must be shown on the Final Plan. Any excess driveways must be closed, i.e., replaced with curb, gutter and sidewalk. A facilities permit will be required from the State Highway Division for any driveway since Main Street is part of the State Highway system. Contact Larry Asburry at 726-2252. " . ,.. --- Page 2 Hyland Type I Site Plan d. The existing hydrant on Main Street needs to be shown. The driveway needs to be setback at least 3 feet from the hydrant. e. A landscape plan is required. A five foot-wide landscape strip is required behind the property line along main street. The minimum planting acceptable per 1,000 square,feet of required planting area is as follows: 10 shrubs, five gallons or,larger. Street trees (at least 6 feet high and not less than 2" in caliper) are required at 30 foot intervals. The names of the trees and plants will be required to be shown on the Final Plan. An irrigation plan is required unless there is written' verification from a licensed nurseryperson and a program to ensure that the proposed plant materials will have at least a 90 percent survival rate over a five year period without an irrigation system. 2. Recordation of the required 10 foot sidewalk and public utility easement at Lane County at the applicant's expense. 3. Yater is available but not paid for. Utility Board at 746-8451. Contact Chuck Davis at the Springfield 4. A Development Agreement will need to be signed. This document will be prepared by staff upon approval of the Final Site Plan. ADDITIONAL INFORMATION 1. The property address must be placed on the fence along Main Street and be visible from the Street. 2. There is an existing sanitary sewer line at the south east corner of the property. 3. No maintenance will be ,allowed at this site. This approval is for storage only. APPEAL If you wish to appeal this Type I Site Plan Review decision, you must do days of the date of this letter. Your appeal must be in accordance Development Code, Article 15, APPEALS. so within 10 Springfield QUESTIONS Please call the Development Services Department at (503) 726-3759 if you have any questions regarding this process. PREPARED II ~rp ,Associate Planner ./~ Copy To: DRC Members