HomeMy WebLinkAboutOccupancy Correspondence 1983-4-12 . . SPRINGFIELD , CITY OF SPRINGFIELD Department of Public Works April 12, 19B3 " / / " John and Dave Hyl and . 1941 Laura Street :i',.Springfield, Oregon 97477 RE: Occupancy Inspection of Structures at 1941 Laura Street, Springfield, Oregon ,,' ," , " " . 'j'I' ':-' " .:; 'l,.i:"~' '. Dear John and Dave, At your request, the City Building Division inspected the existing house and a mobile home at 1941 Laura Street for suitability to be used as offices for your construction business. , '1 In addition to the requirements of your Conditional Use Permit, the following items 'are required to comply with,minimum Code standards for the intended use. , Items relative to the house: State Structural Specialty Code and Fire and Life Safety Code 1) The upstairs shall be used for light storage only, not in excess of 40 p,s,f. floor live;load.', :Table 23-A Oreqon Pl umbi nq SDec i a lty Code' 1) Water closet bowls for public use shall be elongated bowls equipped with open front seats. Section 901 2) The washer discharge inlet shall be plugged. Section 314 (c) Oreqon Electrical SDecialty Code 1) , Repair the 1 ight fixture in the breezeway connecting the house and the mobile home. Section 110-3 (A-B) 2) Remove or repair the dryer outlet. Section 110-3 (A-B) 3) Remove extension cords used as permanent wiring, and install outlets as needed. Section 400-B 4) Install a switch for the light in the upstairs storage area. Section 410-52 5) Install cover plates on all outlets and switches. Sections 410-56 (c) and 370-15, 17 & 18 225 North 5th Street · Springfield, Oregon 97477 · 503/726-3753, -' \ '.. '. ....,. " _. _~.'t. . 0._ _ _. .~ '"' ~ , " . . John and Dave Hyland Occupancy Inspection 1941 Laura Street April 12, 1983 Page 2. Items relative to the mobile Home: State Structural Specialty Code and Fire and Life Safety Code 1) The unused patio door shall be secured in the closed position if it is to be unused. Secti on 3303 (i) / Oreqon Electrical Specialty Code 1) Li ght fixtures shall be hard wi red. Zip cord is not approved as permanent':: wiring. Section 400-8 2) Two service drops are not permitted. Sub-feed the mobile home office from the main building panel. Section 230-2 3) Steel flex conduit shall not be in direct contact with earth. Section 230-43 & 300-6 (b) 4) Outlets are not permitted over baseboard heaters. 5) In the area where .the breezeway was added, re-wire outlets as needed. junction boxes are not allowed. Section 110-8 & 370-19 U.L. Listing Section 100-3 Concealed Oreqon Statutes Governinq Mobile Homes 1) The State mobil e home ins i gni a 1 abel shall be removed from the former mobil e home unit since it has been modified ,and is no longer suited for use as a mobile' 'home. Present the label to the City Building Division and we will mail to to the State Mobile Home Section. City Zoni nQ Code 1) All mobile homes shall be skirted in accordance with O.A.R. 23.070. Section 8.08 (N) Items relative to the garage: State Structural Soecialty Code and Fire and Life Safety Code 1) The existing garage structure shall be used only for storage purposes. Tables 5-A '" 5-B Oreqon Electrical Soecialty Code 1) Protect and properly secure NM cable feeding power to garage area. Section 110-8 ~-'.'._" ........ ..... . . John and Dave Hyland Occupancy Inspection 1941 Laura Street April 12, 1983 Page 3. '>,.l When the above items have been completed; call the Building Division inspection request line at 726-3769 and state'the type of inspection requested. / Questions regarding the above items should be directed to the various specialty inspectors at 726-3753. Sincerely, ;:(~ t.v.~~..":) .'1: Lorne \.!. Pl eger Senior Plans Examiner LWP /l h ,. .. _...~ .':!_..<......;: ,--"". .~'.