HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-5-15 "L' "'" .a K & A Engineering, Inc. 3327 Roanoke Ave., Eugene, OR 97408 (541) 684-9399 Voice (541) 684-9358 FAX engineering May 15, 2007 Project: 151.06 Hayden Enterpnses, Inc, 2464 SW Glacier Dnve #110 Redmond, OR 97756 Subject Jasper Meadows subdlvlsion--Lot 209 -57 (po Of35iol r~ Y\ Springfield, OR Foundation SOils PURPOSE AND SCOPE At your request, K & A Englneenng, Inc. has completed a geotechnical investigation of the eXisting sOils on the subject property, Our understanding is that a wood-framed single-family residence supported by a casHn- place concrete spread footing foundatIon is proposed for constructIOn on this site The purpose of our investigation was to determme the suitability of the sOils for construction of the proposed structure, and provide recommendations for construction of the foundation The scope of our services IS limited to general sUitability with respect to beanng capacity and expansive soils FOUNDATION PAD PREPARATION The project site IS located on a residential lot in the new "Jasper Meadows" subdivISion The lot IS mostly level and there are no apparent slope movement hazards Foundation preparation Involved constructing a level foundation pad on native undisturbed sOils, This reqUired excavating and removing undocumented fill, loose organic silt, and plastic silt from the foundation pad area, After the excavation and removal of these salls, approximately 12-lnches of %-mch minus dense graded crushed aggregate was placed and compacted over approximately 2,0 to 4 O-feet of 8-lnch mmus "pit run" fill This served to provide a uniform surface for footing construction, The fill matenals were placed In maximum lifts of 12-inches and compacted uSing a vibratory steel drum roller We tested the In-place density of the crushed aggregate fill and have determined that the average dry denSity exceeds 95% of maximum as determined by ASTM 0698 The field test results are attached to thiS report, ~ ''I K & A Engineering, Inc. SUMMARY AND RECOMMENDATIONS The project site, as prepared, IS sUitable to support the proposed foundations We recommend a design allowable beanng capacity of 2,500-pounds per square foot The sOils present a moderate shnnk/swell hazard Foundation loads should bear on undisturbed native silts a mInimum depth of 36-Inches below fInal grade around the penmeter foundation The prepared foundation pad meets these recommendations FInal gradIng around the foundation pad should raise the grade above the foundation USIng native or Imported silts and should slope away from the foundation We recommend approval of the foundation pad, as constructed, by the building official Thank you for the opportunity to be of service, Please call us if you have questions or need further assistance Respectfully, Steve Schultz, E I T K & A EngIneenng, Inc EXPIRES lDFC' 3 (} 200~ . Revised on 11/19/07 due to the platted lot numbers being different than the design lot numbers Client Hayden Enterpnses Jasper Meadows-Lot 209, Spnngfleld, OR Project 151 06 Page 2 of 2 May 15, 2007 ~ Density of Soil and Soil-Aggregates In-Place ASTM 02922 and 03017 Project: 151 06 Site Address: Jasper Meadows--Lot 209 Permit No: Date' 5/9/2007 Density Test Type': DT-6 Operator: SS Material Type: 3/4" (-) from Spnngfleld Quarry I Maximum Dry Denstiy, pcf 128 0 Standardization and Reference Check ~ Density (Standard Deviations). (S D.) 1 71 ~ Moisture, ,(S.D:) 1 53 Moist Dry Density, Density, Water Compaction, Test No. pcf pcf Content, % % Remarks 1 1330 1254 61 979% 2 1369 131 8 3,9 102 9% 3 1370 1297 56 101 4% I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Average: 100.7% Std Dev 256% , Direct Transmission (DT) (specify depth, In ) or Air Gap Backscatter (AGB) (speclfly(T)ouchable or (U)ntouchable mode Test performed uSing Seaman Nuclear Corp model C-300, SN 21113 Client Hayden Enterpnses, Inc Project 151 06 K & A Engineering, Inc. 11/19/2007