HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-8-20 . p, ~ " ~ .a K & A Engineering, Inc. 3327 Roanoke Ave., Eugene, OR 97408 (541) 684-9399 Voice (541) 684-9358 FAX f>nginf>f>ring August 20, 2007 Project: 151.06 Hayden Enterpnses, Inc 2464 SW Glacier Dnve #110 Redmond, OR 97756 SUbject' Jasper Meadows subdlvlslon--Lot 262 .- 57q I ~V'V\I((" Springfield, OR Foundation SOils PURPOSE AND SCOPE At your request, K & A Engineering, lnc, has completed a geotechnical investigation of the eXisting sOils on the subject property, Our understanding is that a wood-framed single-family residence supported by a cast-In- place concrete spread footing foundation IS proposed for construction on this site The purpose of our investigation was to determine the suitability of the sOils for construction of the proposed structure, and provide recommendations for construction of the foundation The scope of our services is limited to general sUitability with respect to beanng capacity and expansive sOils FOUNDATION PAD PREPARATION The project site IS located on a residential lot In the new "Jasper Meadows" subdivIsion The lot IS mostly level and there are no apparent slope movement hazards Foundation preparation Involved constructing a level foundation pad on native undisturbed sOils This reqUired excavating and removing unsuitable soils from the foundation pad area After the excavation and removal of these salls, approximately 1 Q-foot of %-inch minus dense graded crushed aggregate was placed and compacted over 8-lnch minus "pit run" fill The "pit run" typically consisted of a dense graded crushed gravely silt with cobbles up to 8-inches This served to provide a uniform surface for footing construction The fill matenals were placed and then compacted uSing a vibratory steel drum roller We tested the In-place density of the crushed aggregate fill and have determined that the average dry density exceeds 95% of maximum as determined by ASTM 0698 The field test results are attached to thiS report .. ':" K & A Engineering, Inc. iI. SUMMARY AND RECOMMENDATIONS The project site, as prepared, IS sUitable to support the proposed foundations We recommend a design allowable beanng capacity of 2,500-pounds per square foot The sOils present a moderate shnnk/swell hazard, Foundation loads should bear on undisturbed native silts a minimum depth of 36-lnches below final grade around the perimeter foundation The prepared foundation pad meets these recommendations Final grading around the foundation pad should raise the grade above the foundation uSing native or Imported silts and should slope away from the foundation We recommend approval of the foundation pad, as constructed, by the building official Thank you for the opportunity to be of service Please call us If you have questions or need further assistance Respectfully, Steve Schultz, E I.T K & A Englneenng, Inc EXPIRES DEe' 3 0 200~ Client Hayden Enterprises Jasper Meadows-Lot 262, Springfield, OR Project' 151 06 Page 2 of 2 August 20, 2007 Density of SOIl and Soil-Aggregates In-Place ASTM 02922 and 03017 Project: 151 06 Site Address: Jasper Meadows--Lot 262 Permit No: Date: 8/16/2007 Density Test Type': DT-4,6 Operator: SS Material Type: 3/4" (-) from Springfield Quarry I Maximum Dry DenstlY, pcf 1280 Standardization and Reference Check A Density (Standard Deviations) (S.D.) 0.89 A Moisture, (S 0:) 1 76 Moist Dry Density, Density, Water Compaction, Test No. pcf pcf Content, % % Remarks 1 1424 1333 68 1042% 2 128.1 1192 75 931% 3 1324 1230 76 961% I I I I I I I I I I I I I Average, 97 8% Std Dev, 572% 1 Direct Transmission (DT) (specify depth, In) or Air Gap Backscatter (AGB) (speclfly(T)ouchable or (U)ntouchable mode Test performed uSing Seaman Nuclear Corp model C-300, SN 21113 Chent Hayden Enterprises, Inc Project. 151 06 K & A Engineering, Inc. 11/19/2007