HomeMy WebLinkAboutPermit Signage 1992-3-2
city of springfield
225 n. 5th' street
, .
SPRINGFIELD
-
I N FORMATION: 726-3753
.
.
INSPEC'T10NS: 726.3769
~lq,.J @
SIGN PERMIT APPLICATION
,A, LOCATION OF SIGN (ADDRESS) q~7 UV5t: 'y./A'-I
LECAL DESCRIPTION I/O~2-~?O
OI./NER OR PROPERTY V, F. :2. e..E'-'5
ADDRESS e>+2 E.. c.-'r'P{l.f,.~S ~WrJII.J",. Ut.
OIINER OF SIGN (IF OTHER THAN PROPERTY OWNER)
ADDRESS
"iAMl!!
SPf1? "I!-,
TAX LOT -t' 00 q ID
PHONE q/f,- 2.7.:3- o~"'D
ZIP 1'- ()O ~
( #lIti /ZDsl!.- ~LJVrl'tflll")
PHONE "'11"'-2.2.3-0'513
TYPE OF .BUSIllESS. eG~"TNIZ-AJ.JI
NAME OF BUSINESS, FIRM, ETC.
DE..t-IJ.4l,1'S
B, TYPE OF WORK:
XERF.CT _ALTER
_RELOCATE
_OTHER
C, STRUCTURAL TYPE 'OF SIGN:.
_HALL ..1(yREESTANDUlG
_ROOF PROJECTING
_MARqUEE
_UNDER I1ARqUEE
_OTHER
D, USE AND CP.ARACTER OF SIGN:
XIDENTITY
_INCIDENTAL
~DOUBLE FACE
_SINGLE FACE
_MULTI-FACE
READER BOARD
_BILLBOARD
E
.' DIHENSIONS, llISTALLATION & CONSTR 1
,~I_O;'
TOTAL HEIGHT ABOVE GRADE ~~
VERTICAL DIMENSION OF SIGN /D'-:q"
HORIZONTAL WIDTH OF SIGN 2., ' ,lo ·
DINENS ION FROM GRADE TO eLl.. I 3 ..
BOTIOM OF SIGN '.rr -
TIlICKNESS OR DEPTH 10 ·
E, VENDORS, CONTRACTORS:
SIGN EReCTOR tl/&,J;,.iE. S 1"iN 2- AL./UJ"'e, ?O, PIlONC 4-Bc; - S'.S %
.f,DD~-ESS 12.10 OA-fC.. P"tTC- H fU).' ZIP "174-0 '2.
CITY LICENSE Ntl!1BER .:,.-0 - 2... 55 C-L5 (1(1;P:; ( n::-04 07 EXP. DATF. 10- I - ~ . .
SIGN HANUFACTURER (IF OTHER THAN ERECTOR) - . C:;AI"t~1 t., ZU ':1'~ 1(1 tot ql/)l.~//o .30Q
.\.DDRESS PHONE'
\
~"
G. EXISTING SIGNS t9
ARE TIlERE ANY EXIST!!lG f.IGNM "-Y . x.rio
rnJHBE? SIZE IN . ,
ALL F~ISTING SIGNS' I
FOR EUSINESS, ETC.
DOES SIGN PROJECT BEYOND
PROPERTY LINE? ___YES
IF YES, DINENSION BEYOND
PROPERTY LINE
NOTE: IF PROJECTIOn IS rlORE ,THAN lZ"
OVER PUBLIC PROPERTY THE 'SIGN ERECTOR
I-lUST FILE WITH THE BUILDING DIVISION
COPIES OF I1IS/IIERLIABILITY AND PROP-
ERTY DANAGE .IlISURANCE POLICIES.
~
.- -- -
H, HI~L SIGN HAVE ELECTRICAL lVIRING("Y~ .-J
IF YES, ~ICH APPLY? ~ELECTRICAL 'Lvrl .
_ILLtl!1INATED (INDIP-EcTI:Y LIGHTED) e"'1"""~
ELECTRICAL COtITRACTOR M41-/C.. ~~r/Ut- $'f"'I~,
ADDRESS_'11'o DA1f:~H i?::P'
LISC.NUMBER 4<,.c SZ: PI:ON1: 413t;-'<5~S:%
I, DESCRIBE TYPE OR I'ATERIALS SIGN IS
CONSTRUCTED OF.
""~U- J>t~ ". FLb< ~AU5
I.U" f/...VD~r;~f.~ (~S
~rt€.L PiP'- S"~'iJlt,-rs
I
J, SITE INFOF1IATION (LAND USE) -- EXISTING USE
OF BUILDING OR LAND (nR LAST USE IF VACANT)
I/AG-AN'f tAIf
fH~w /?'IJI L.D,,.,'"
K, VALUE OF SIGN: "32, 1BB. 00
___INDOOR BUSINESS OUTDOO~ I'ERCHANDISING
PROPOSED USE OF BUILDING OR LAND:
'AI IA:l>L Jl.us I ""~S
12..~ TAVtU>ivr
.
L, I HAVE CAREFULLY EXANINED the .completed application for permit and do hereby certify that all
. information is true and correct, and I further certify that all work performed shall be done in
accordance with the Springfield Sign Ordinance. the Uniform Sign.Code as adopted by the City of
Soringfield,and all other Ordinances of the City of SprinRfield and the laws of the State of
~regon pertaining to t~e work described nC4~Ln. I further certify that my ~~r.n Co~tractor Li-
cense with'the City of Springfield is in full force and effect as required by Sprlnp.field Codes
8-Z-6~3) and 9-7-Z0(Z). I will request all required sign inspections listed on the approved
permit. '
NANE (PLEASE PRINT)W1G,.J€. S,'1N 9< A'<'PI~'i
1...;"j.. I!-- (IZU.)
~, .~
",
'DATE 2 - -S - .., 2..
SIGNATURE
.......1.
-
PLEAS E
REA'
.
i
1)
A separa~e application is required for each separate sign as defined "
2)
Seoarate Sien A~olication:
in the Sign Code.
Electrical: Any permit issued under this application will includ~ wiring in or on sign structure,
the supPlY wires for connection must be covered on an electrical permit. Electrical connection
must be made only by a State Licensed Electrical Contractor. Illuminated signs (both internally
and externally) must conform to Sections 9-7-4 (4) & (5) and .9-7-18 of the Springfield Sign Or-
dinance.
3)
Plans ReQuired: This application is to be submitted with two complete sets of plans showing di-
mensions and neight of sign; advertising message on sign; location of sign on property with di-
mensions to property lines, structural details of support framing, bracing and footines; materials
of construction for sign and sign structure; e~ectric~l equipment and lighting:- size and location
of existipg signs on prope~ty for the same busienss, all as required to determin~ com~liance with
the Springfield Sign Ordinance. (Article. 7 of the Springfield City Code), Also " show the follow-
.ing information on the plot plan (plan showing property lines and location of signs):
a) Show the location of all existing sign(s) as well as proposed sign(s).
b) Show the length of the street frontage taken up by the business or building, For wall
signs, show the length of the building frontage,
c) Show the location of entrances open to the public and driveways.
When required, because of design, size, etc., engineered drawings and calculations must be pre-
pared by a licensed engineer or shall conform to design standards on file at t~e Building Divi-
sion Office,
Plans of insufficient clarity or detail will be returned to the applicant with no permit being
issued.
'Signs must meet corner vision clearance requirements as described in Figure 9 of the Springfield
'Comprehensive Zoning Code.
NOTE: .No sign may be erected which is less than 12 feet horizontally or vertically from overhead
electrical conductors in excess of 750 volts, or less than 5 feet in any direction froc overhead
electrical lines which are energized at less than 750 volts.
If a sign is not installed within 60 days after the date of issue of this permit, the permit shall
be void. .
Insoections:
~
4)
5)
6)
~
7)
..
8)
9)
a)
Site Inspection - to be made before the sign is placed. Usually, the Footing Inspection
(it appficable) may be made at the same time as the Site Inspection. lbe rooting Inspec-
tion is to be made after hole(s) is e~avateci, but prior to the placement of concrete.
Final Insoection:- to be made upon completion of all work. '
Electrical'. all electrical signs must be inspected for electrical hook up after the sign
is erectea and before the sign is turned on. .
b)
c)
CALL FOR THE REQUIRED INSPECTIONS ON THE 24' HOUR INSPECTION LINE AT 726-3769
FOR OFFICE USE ONLY
SIGN DISTRICJ-~ ZONE DISTRICT (~:'
TOTAL SQUARE FOOTAGE OF SIGN dJ~~ ~ R (} ,~rrl 0 ~ ·
REOUIRED INSPECTIONS:
SITE/LOCATION 'i FOOTING OR METHOD OF ATTACHMENT
2(ELECTRICAL 'I. FINAL
OTHER
~ G\\\\~
JOB ~
SIGN PERM~JjDLo. ;l)
~~~&0ho~
57o-S'I'-A:rE-SUR.{)IIARGE":
TOTAL: cDOlo.HJ
DATE I~ ,~q~. CEIPT<-~1&.7.
CLERK (.iYA / I
..; - .-- I
SPECIAL CONDITIONS TO BE SATISFIED BEFORE ERECTION OF SIGN:
ADDITIONAL INFORMATION NEEDED BEFORE PERMIT MAY BE ISSUED:
APPROVED
.
pATE ~. )~ .q;)-
SECTION:
SPRINGFIELD SIGN ORDINANCE