Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1999-3-16 . . La' ~~ ., Information ~~. .To Build On Engineering. Consulting. Testing -t;z8/G11 " REPORT OF EPOXY ANCHOR INSPECTION TESTED FOR HA YDEN HOMES PROJECT HA YDEN GARDENS 3258 PINYON SPRINGFIELD SPRING'FIELD. OR 97478 ATTN ALICIA WOBBE DATE MARCH 16. 1999 REPORT NO 722-90044-2 AS REQUESTED. PSI REPRESENTATIVE RALPH TURNER WAS ON SITE THIS DATE FOR THE PURPOSE OF VISUALLY INSPECTING ANCHORS AS FOLLOWS USE OF ANCHORS (SELECT ONE) 1) IS REQUIRED BY DRAWINGS DRAWING NO(S} DATED . STAMPED APPROVED BY 2) IS REQUIRED BY APPROVED CHANGE ORDER 9911620 BY J R BONNET ENGINEERING APPROVED CHANGE ORDER ATTATCHED 3) HAS NOT BEEN APPROVED IN WRITING BY PROJECT DESIGNER AS OF THIS INSPECTION ~~l EPOXY DESCRIPTION REQUIRED SIMPSON STRONG-TIE CONNECTORS 5/8" ALL THREAD I ACTUAL SIMPSON STRONG-TIE CONNECTORS 5/8" ALL THREAD ANCHOR DESCRIPTION (DIAMETER, LENGTH, TYPE) HOLE CLEANING METHOD (I E . DRIED. BRUSHED, BLOWN) HOLE DIAMETER (INCHES) MINIMUM ANCHOR EMBEDMENT DEPTH (INCHES) DRIED BLOWN DRIED BLOWN "j.," "j.," 9" 9" LOCATIONS AND QUANTITY INSPECTED ALONG SHEAR WALL IN RESIDENCE 3342 PINYON AVE (9) 5/8" ALL THREADS PLACED 9" DEEP WITH 1" OF THREAD SHOWING AFTER THE ANCHOR HAD BEEN PLACED REMARKS ANCHORS INSPECTED DO MEET THE REQUIREMENTS IDENTIFIED ABOVE_ RESPECTFULLY SUBMITTED. PROFESSIONAL SERVICE INDUSTRIES, INC CC CITY OF SPRINGFIELD - BOB BARNHART Professional Service Industnes, Inc' 2710 West 5th Avenue' Eugene, OR 97402' Phone 541/484-9212' Fax 541/344-2735