Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1999-4-12 . . l"'!:;pnforrnation ~WII. .To Build On Engineering. Consulting. Testing 93 10 10 REPORT OF EPOXY ANCHOR INSPECTION TESTED FOR HAYDEN HOMES PROJECT HAYDEN GARDENS 3258 PINYON SPRINGFIELD SPRINGFIELD. OR 97478 A TTN ALICIA WOBBE DATE MARCH 12. 1999 REPORT NO 722-90044-1 AS REQUESTED. PSI REPRESENTATIVE RALPH TURNER WAS ON SITE THIS DATE FOR THE PURPOSE OF VISUALLY INSPECTING ANCHORS AS FOLLOWS USE OF ANCHORS (SELECT ONEl 1) IS REQUIRED BY DRAWINGS DRAWING NO(S)' DATED ,STAMPED APPROVED BY 2) IS REQUIRED BY APPROVED CHANGE ORDER APPROVED CHANGE ORDER ATTATCHED 3) HAS NOT BEEN APPROVED IN WRITING BY PROJECT DESIGNER AS OF THIS INSPECTION X " REQUIRED SIMPSON STRONG-TIE CONNECTORS 5/8" ALL THREAD 10" ACTUAL SIMPSON STRONG-TIE CONNECTORS 5/8" ALL THREAD EPOXY DESCRIPTION ANCHOR DESCRIPTION (DIAMETER, LENGTH, TYPE) HOLE CLEANING METHOD (I E , DRIED, BRUSHED, BLOWN) HOLE DIAMETER (INCHES) MINIMUM ANCHOR EMBEDMENT DEPTH (INCHES) DRIED BLOWN DRIED BLOWN 0/.," 0/.," 8'12" - 9" 8'12" - 9" LOCA TIONS AND QUANTITY INSPECTED HOUSE AT 930 32nd PLACE THE CONTRACTOR DID NOT MIX THE EPOXY ACCORDING TO MANUFACTURERS RECOMMENDATIONS UNTIL PSI REPRESENTATIVE READ THE MIXING INSTRUCTIONS AND BROUGHT IT TO HIS ATTENTION REMARKS THE ANCHORS WERE PULLED OUT AND THE EPOXY WAS MIXED PROPERLY AND REPLACED RESPECTFULLY SUBMITTED. PROFESSIONAL SERVICE INDUSTRIES. INC CC CITY OF SPRINGFIELD - BOB BARNHART Professional Service Industnes, Inc. 2710 West 5th Avenue. Eugene, OR 97402. Phone 541/484-9212. Fax 541/344-2735