Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2001-12-12 ~ STRUCTURAL BUILDING DESIGN · FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION MORTIER ENGINEERING, EC. 1245 PEARL STREET "OUGENE, OREGON 97401 HONE (541) 484-9080. FAX (541) 484-6859 lOll FREE IN OREGON 1-877-661-9959 December 12. 2001 Masada Development 2181 Wisconsin Eugene, Or 97402 RE: 852 South 73rd Springfield- Site/Soils/Compaction Investigation - W.O. #14084-PSH As you requested, a site/soils investigation was perlormed at the above noted address on December 10, 2001. Design for the site is as follows: , All fill, vegetation, and unbuildable material has been removed to native grade. The native soil is clay with a Unified Soils Classification of CL and a plasticity index greater than 20. The soil is moderately expansive. A minimum of 12 " crushed rock should be installed with tracked excavation equipment to moderate the effect of the expansive soils at the proposed building site. The crushed rock should be placed and then compacted with either a vibratory plate or roller. Drainage shall be installed at the perimeter footings to help maintain optimum soil moisture at the site. With the placement of the crushed rock, and combined with the excavation that is of adequate depth and width, the site as prepared is adequate to assure a stable moisture content for the proposed foundation. On December 11, 2001 a compaction inspection was perlormed after fill placement. The compacted surlace of the 1 1/2" minus crushed rock is adequate for a foundation bearing capacity of 1500 psf, which is adequate to support the proposed conventional wood frame structure. Thank you for this opportunity to be of service. The enclosed Building Analysis Report and Statement of Conditions and Limitations is a part of this report. If you have questions regarding this report, please contact me at 484-9080. Sincerely, fl.! Of ~ .. STRUCTURAL BUILDING DESIGN · FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION MORTIER ENGINEERING, EC. 1245 PEARL STREET E:UGENE, OREGON 97401 -lONE (541) 484-9080 . FAX (541) 484-6859 ,Oll FREE IN OREGON 1-877-661-9959 BUILDING ANALYSIS REPORT Statement of Conditions and Limitations CLIENT Masada Development LOCATION OF PROPERTY 852 S 73rd WO# 14084-PSH Type of InspectIOn and Items mspected IS Imllted to a Structural CondItIOns b _ Weatherproofing (Extenor surfaces) c _ Storm Dramage (BUlldmg, SIte) d _x_ SIte CondItIOns (SOIls, GeologIcal) e _ Plumbmg (FIxtures, Plpmg) f _ Heatmg (Furnace, Heat Pump, AIr CondltIOnmg, FIreplace, Stoves, Chmmeys) g _ Electncal (SerVIce, Wifing, Outlets) h _X_ Other COMPACTION The inspectIOn IS for the purpose of alerting the clIent to major defiCIencIes In the conditIon of the property descnbed above and according to the conditIOns contained In the report and thIS statement The InspectIOn and report are performed and prepared for the sole, confidentIal and exclUSive use and possessIOn of the CLIENT No oblIgatIOn or responsIbIlIty to other partIes IS assumed ThiS inspectIon IS of the readIly acceSSIble areas of the buIldIng and IS lImited to VIsual observatIOns of apparent conditIons eXisting at the tIme of the InspectIOn Latent and concealed defects and defiCIencies are excluded from the inSpectIOn, eqUIpment, constructIOn and systems Will not be dIsmantled MaIntenance and other Items may be discussed, but they are not a part of our inspectIOn The report IS not a comphance inspectIOn or certIficatIOn for past or present government codes or regulatIOns of any kind The InspectIOn and report do not address and are not Intended to address the pOSSIble presence of or danger from any potentially harmful substances and environmental hazards including but not lImited to radon gas, lead paint, asbestos, urea formaldehyde and tOXIC or flammable chemIcals Any references made to these substance In our report are made for the sole purposes of alertIng our clIent to the pOSSibIlIty of their eXIstence We are makIng no posItive determinatIOns as to their actual presence, as we do not do laboratory testing If CLIENT wishes any further InformatIon or recommendatIOns In regard to the presence of these substances, we recommend contacting a speCialIzed envIronmental contractor The report descnbes the property condition and status on the date of IllspectlOn The purpose IS to alert clIents to present defects Sub-surface SOlI conditions, Illaccesslble areas and features, applIances, secunty alarms, Illtercom systems, solar heating systems or panels, spnnkler systems, spas, pools, water softeners, central vacuum systems, and the presence or absence of rodents , termItes or other Illsects are speCifically excluded from the scope ofthls report WhIle every I easonable effort was made to determine the property condItIons, no guarantees are expressed or ImplIed No responSibilIty IS assumed for any Items outSide the scope of thIs IllspectJOn, nor can we be held responSIble for work performed by others Llablhty for damage ansmg out of errors or omISSIOns shall be hmlted to tile cost of the scope of IllSpeCtIon No representatIOns are made concerning the archItectural or engineering conditions MortIer EngIneel Ing, ItS employees and agents, assume no llablhty or responSIbIlIty for the cost of repamng or replacing any unreported defects or defiCiencies, either current or aflSIng In the future, or for any property damages, consequential damage or bodIly injury of any nature The inspectIOn and report are not Intended or to be used as a guarantee or warranty, expressed or ImplIed, regarding the adequacy, performance or condItIOn of any Inspected structure, Item or system For MORTIER ENGINEERING, P C G~/ Signature Vkr.., A- J' r~ TItle December 12.200] Date