Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1984-11-6 I . C-' @ .~~ p, . 50-5101 PTL-EuaENE Pittsburgh Testing Laboratory 545 CONGER STREET . eUGENE. OREGON 97402 503/484-9212 [R1~~~[R11J # 1 ORDER NO, EUG 3976 DATE November 6, 1984 Ross Building Systems P,O. Box 713 Creswell, OR 97426 REPORT OF: PROJECT: Structural Welding Special Inspection Mohawk Valley Grille Works 3852 Kathryn Springfield, OR 97477 # 84069,6 11-5-84 and 11-6-84 ~ PERMIT NUMBER: INSPECTION DATES: INSPECTOR: Michael G. Mabrey, PTL SUPPLIER/CONTRACTOR: Ross Building Systems Visual we1dment inspection was performed on the. extension ridgid frame columns and extension end wall columns after their installation, The ridgid frame columns differed from the approved drawings in that gusset plates were welded to both sides of the tube steel at the top and bottom connections. Also, splice plates were welded to all four sides of end column connections, Both changes should enhance the strength of these connections. Welding was perfonned by Ralph Sackett', ,Jr, "with SMAW process using ,E7014 electrodes and a Lincoln 250 Amp welder. Some difficulty was reported in maintaining the proper amperage, so a Lincoln 400 Amp welder was used to complete the.project. Since Mr. Sackett holds certifications in gas metal arc welding only, he will take the qualification test for shielded metal arc welding as soon as possible. The results of this test will be sent to the contractor and the City of Springfield Building Dept. when completed, . ALL RGPORTS ARE Bl.JElfvIITTEO AS Tt-E CClN"lOENTIAL .-~_'__', OF Cl.ENTS PUBLICATION OF STATEMENTS. CONCLUSIONS OR EXTRACTS IS ReSERVED PENOII"oIG OUR WRITTEN APPROVAL. /~ l .. . ... Ross Building Systems Page 2 PITTSBURGH TESTING LABORATORY EUG 3976 November 6, 1984 All fillet welds were 3/16" or larger with the 'exception of those at five of the column bases. These were corrected and approved on November 6, 1984. Welds were free of cracks and craters, porosity was minimal and weld profiles were acceptable. One weldment was rejected for excessive undercut and another for overlap, Both were repaired in a satisfactory manner and approved on November 6, 1984, at which time all welds were in accordance with the quality requirements of AWS 01,1-84, Respectfully submitted. PITTSBURGH TESTING LABORATORY \-,}i: \. ~3 :~ Q \--'~..-0 J~rry L. Johnson, Manager Eugene District MGM:ab