FIBER GLASS BLOWING INSULATION
BATTS AND BLANKETS
When installed in accordance with the man-
ufacturer's recommendations, Knauf batts
and blankets will provide the full R-value.
I MINIMUM
R.vALUE* THICKNESS
To obtain an Installed Insulation
insulation resistance should not be
(R) of less than.
R-38
R, 30HD
R-30
R-26
R-22
R-21HD
R.19
R.15HD
R.13
R-11
R,8
12,00"
8,25"
10.00"
9.00"
6.50"
5,50"
6.25"**
3.50"
3,50"
3.50"
2,50"
Bag Weight-Nominal 28 bs.. Minimum 271bs.
uR.18 in a 5.5" cavity. Conforms to ASTM (665 and
Federa!SpecificalionHH-I-521F.
EQUIPMENT REQUIRED
THERMAL PERFORMANCE (ATTIC APPLICATION)
The stated thermal resistance (R.value) is provided by installing in accordance with the manufacturer's instructions,
the required number of bags per 1,000 sq. ft. of net area, at not less than the labeled minimum thickness. failure to
install both the required number of bags and at least the minimum thickness will result in lower insulation R,value.
BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM
R-VALUE* 1,000 SQ. FT. NET COVERAGE PER SQ FT THICKNESS
To obtain an The number of bags per (ontents of thiS bag The weight per sq. ft. Installed insulation
insulation resistance 1.000 sq ft of net area should not cover of Installed insulation should not be
(R.value) of. should not be less than more than: should not be less than. less than.
\
R'50 31.0 32.25F .8691bs, 20,00"
R.44 26.9 37.2 SF .753Ibs. 17.75"
R.38 22.9 43.6 SF .642Ibs. 15.50"
R-30 17.9 55.9 SF .501Ibs. 12.50"
R-26 15.5 64.6 Sf .433Ibs. 11.00"
R.22 12.7 78.4 SF .357Ibs. 9.25"
R.19 10.9 92.0 SF .304Ibs. 8.00"
R-B 7.6 131.6 SF .213lbs. 5.75"
R-ll 6.2 161.3 SF .174Ibs. 4.75"
I This product conforms to the performance requirements of ASTM C 764, Type I. and cancelled Federal Specification HH+I030B, Type I,
ClassB.R.valuesaredeterminedinaccordancewithC687andC518.
."R" means resistance 10 heat flow. The higher the R-value. the gre atertheinsulalingpower.AskyoursellerforthefactsheetonR.values.
To achieve labeled R-value, this product must be applied with a pneumatic blow-
ing machine and a corrugated hose with a minimum .25" internal corrugation, a
minimum length of 150 ft. and a diameter of at least 3:' Coils in the hose should
not be less than 36" in diameter. Acceptable material feed rate is 5.35
lbs./minute._ Recommended feed rate is 15.25 Ibs./minute.
BUILDER'S INSULATION STATEMENT
Batts andlor blankets have been installed in conformance with the above recom-
mendations to provide a thermal resistance of. . .
R Value Thickness
Attic Area
Sloped Ceilings
Walls
Floors (over an unheated crawl space)
Crawl Space Perimeter
O'n
Date Installed lJ- ...,
R, ~ 5?"at /6 Inches
R, at Inches
R'V at .fa Inches
R- z5 at 't -i::, Inches
R- at Inches
Blown insulation has been installed in conformance w~e above
recom~ndations to provide an R-value of: R- :; if using
/7 bags of this insulation to cover q 0 b square feet
of ~rea at a minimum thickness of / A inches.
..x4LA'-- ,'#~
In~~nptract~e~./'h10/ C t1?? .J-
Companl Dale
Home Builder (signature)
Company
. BW.A(.08 5/02
FRAMING ADJUSTMENT
To compensate for framing members, the number of bags per 1.000 sq. ft. of
area to be insulated should be as shown below.
I JOIST I BAGS{MSF BAGS/MSF
R.vALUE DIMENSIONS 16" 0 C. FRAMING 24" 0 C FRAMING
R-60 2x6 36,8
2x8 36.5
2x4 30,5
R-50 2x6 30.2
2x8 29,8
2x4 26.3
R-44 2x6 26.0
2x8 25,7
2x4 22.4
R-38 2x6 22,1
2x8 21.8
2x4 17.4
R'30 2x6 17,1
2x8 16.8
2x4 15,0
R'26 2x6 14,7
2x8 14,4
2 x4- 12,3
R-22 2x6 12,0
2x8 11.7
2x4 10,4
R'19 2x6 10.1
2x8 9,8
2x4 7,1
R'13 2x6 6,8
2x8 6,6
2x4 5.7
R,l1 2x6 5.5
2x8 5.2
37,1
36,8
30.6
30.4
30.2
26,5
26.3
26,0
22.5
22.3
22,1
17,5
17.3
17,1
15,1
14.9
14.7
12,4
12,2
12,0
10,5
10.3
10.1
7.3
7.1
6.9
5.9
5.7
5,5
CLOSED-CAVITY APPLICATION
~ (EXTERIOR SIDEWALL OR FLOORED
Date I
Contact Knauf Fiber Glass for more information.