Loading...
HomeMy WebLinkAboutPermit Building 2002-9-11 <. '~ 225 Fifth Street Springfield, OR 97477 . I Job# 02-01000-01 I . CITY OF SPRINGFIELD, OREGON . ".,o~ vr:,0 RESIDENTIAL PERMIT City Of Springfield Community Services Division Building Safety Page 1 of5 W TRANS~:01-001057B DATE:SEP 11 2002 AMT RECD:2 $ 5898.35 CHANGE: CASHIER:061 Job Number: 02-01000-01 Office: 726-3759 Inspection Line: 726-3769 ~ Tax Lot #: 03201 T Subdivision: King Solomon Location Of Proposed Site: 6842 Jessica Dr Spr Assessors Map#: 18020314 Lot: 1 Block: Addition: City/StatelZip: Springfield, OR 97477 ,0 Value: $155,337 ~o..} .~~~ ^~ 0'" ,S~ \O"~. ~ 0'" '1,' f:j _~ ~ 0.: _~ ._-.l ~~'- O'~ 'f1}'<' '?)<:Jv 0"" Contractor ~Registration;#' E~piration Date ~o ,\ " \\)' 0" ~0 ~o' '0" David Luce .0\0 ~00'() ~",0 ~~ a. ~ v0~ .,# 6812 A St, Springfield, OR 974770~' oo~ /,~ >1$-,0 <-.,0'" ~0~.",0~ ~, 'b' :;.0 "r::> ~O'< .~ ,,'- 6:\' Steve Hauck A<V~, .:,.0'" r.0~.$>9'47618~o'~',$-"',jII30/2003 ",.,(V _v <ii' '$)'" ~ 'V!l:v 828 S 46th Street, Springfield;;0R,97i178 >\0 :;.0\' ~o~ f?>"5 David Luce ,o'~,c,~ ~~~ ~'1>' c,0~ 0\0 ~r::>\:f .:>.0 _I>' ~o ~0 ~0, " 6812 A St, Springfield, OR 97~'7'7",r::>' ';:'~~ .o\~ 0\'''' , f:j-J ~ \' ~ David Luce 1:5 c,'b' &>'()0 ell \)' 6812 A St, Springfield, OR 97477 <:< Owner: Address: David Luce Phone Number: 541-746-7853 6812 A St Scope Of Work: Single Family Residence New .'" , Contractor Type General Contr Electrical Cont( Mechanical Contr Plumbing Contr SFR same as 02-00583-01 842 S 67th Phone 541-746-7853 541-221-2665 541-746-7853 541-746-7853 Office Use ~<0~~,\ Quad Area: 4RSE Land Use: Single Family Dwelling # Of !i~~~ 1 # Of Units: 1 Zoning Code: LDR O~~~y ~~P: Dwelling Constr. Type: (VN) Wood Frame Bedrooms: 3 ~~~~~ Forced Air Electric Water Heater: Electric Range: Electric _v-~';Q.s..lt.'to(@l1Ige: 1896 ~. "'-"'~~v ~v To request an inspection call the 24 hour recording at 726-3769 ~~I ~. lIs'\'i~ before 7:00 a.m. will be made the same working day, inspections request~~. . ~~-I$''ffIade the following working day. '\~ "'~\S ~.:~\J ~ . .....\:) ,,"'~ <::\'V ReqUired Inspectit . ~'..l .~ '-1 '.' I Buildinll \>f - To be made after excavation but prior to setting forms. -Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation ir -After trenches are excavated. -After forms are erected but prior to concrete placement - Prior to floor insulation or decking. -Prior to decking. -Prior to cover. -Before covering sheathing with finish materials. - Prior to cover. Site Verify Ground Rod Footing Foundation Post and Beam Floor Insulation Ceiling Insulation Shear Wall Nailing Framing Wall Insulation Drywall Bolts installed in concrete Hold Downs Installed Vapor Barrier/Insulation Final Building Temporary Power Rough Electrical Electrical Service Final Electrical Underfloor Plumbing Underfloor Drain Rough Plumbing Water Line Sanitary Sewer Line Storm Sewer Line Perimeter Foundation Drains Backflow Device Final Plumbing Rough Mechanical Final Mechanical CC-Standard . . I Job# 02-01000-01 I Required Inspections Building Page 2 of 5 - Prior to Cover -Prior to taping. - To be done by a State Certified Special Inspector. Provide inspection test reports to City Buildin! - To be made after insulation and required vapor barriers are in place, but prior to any wall coverir -When all required inspections have been approved and the building is complete. I Electrical I -Approval required prior to SUB energizing pole. - Prior to cover. - Must be approved to obtain permanent power. - When all electrical work is complete. I Plumbing -Prior to insulation or decking, - Prior to cover or placement of concrete, - Prior to cover. '- Prior to filling trench. - Prior to filling trench. - Prior to filling trench. -After gravel and filter cloth is installed. but prior to backfill. -After device is installed but before backfilling trench. -When all plumbing work is complete. Mechanical - Prior to cover. -When all mechanical work is complete. I Public Works I -After forms are erected but prior to placement of concrete Street Improvement: Fully Improved Curb Cut?0 Improvement Agr.?D San Sewer Depth (Ft): 5 3 Storm Sewer Available? 0 Special Req.: Security Required: Bond Begin DateTime: 00/00/000000:00:00' Special Instructions: Other Utilities: Project Supervisor: Sidewalk Type: Additional ROW? Size Of Line (in): Downspouts/Drains: Enchroachment Permit: San Sewer Tee (in): Bond End DateTime: Curbside - 5' D 8 To'Storm Sewer 6 00/00/0000 00:00:00' . . Sewer connections are required to follow land use decision. I've included 0 Types Of Warning Devices Reqd. . . . Zoning: LDR FloodPlain? D Wetlands? D Journal numbers 1: 2002-08-262 2: Comments: I Job# 02-01000-01 I . Overlay District: Hillside Development # of Street Trees: 3 3: Additional Requirements: Glenwood Area? D Required Attachments: Source Locn: Material: Planner: Urban Growth Boundary?D Quantity Of Fill: Supplier: Drainage: Floodway FEMA: Construction Types:(VN) Wood Frame Occupancy Groups: Dwelling # Of Buildings: 1 # Of Bedrooms: . 3 Handicap Access? D iArea (Sq. Feet) I Main: 1896 Accessory:708 Fee Same As Plan Review Total Plan Check Building Permit State Surcharge For Building Permit 8% Building Administrative Fee Total Building Minimum Electrical Permit Fee Wiring Footage 1,000 Sq Ft or Less Wiring Footage Each Add'l 500 Sq Ft Temporary: 200 Amps or Less State Surcharge - Electrical 8% Admin Fee - Electrical, Total Electrical Minimum Plumbing Permit Fee Three Bathrooms State Surcharge - Plumbing 8% Administrative Fee - Plumbing Total Plumbing Hood and Exhaust Minimum Mechanical Permit 8% Administrative Fee - Mechanical Vent Fan to One Duct Dryer Vent Mechanical Issuance Flood Plain FEMA: Page 3 of 5 Land Use: Single Family Dwelling Pave Driveway? ~ Private Garage/Carp/Stor # Of Stories: 2 Height (feet): 25 Current Units: Proposed Units:1 Census Code: New SF - detached Total:2604 Paid On Receipt# Plan Check 08/19/2002 10333 BuildinR 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 Electrical 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 PlumbinR 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 Mechanical 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 Value/Quantity I Fee Amount 1 $100.00 $100.00 155,337 $747.65 $52.34 $59.81 $859.80 1 4 1 $.00 $106.00 $76.00 $50.00 $16.24 $18.56 $266.80 1 $.00 $306.00 $21.42 $24.48 $351.90 1 $9.00 $12.00 $3.60 $18.00 $6.00 $10.00 3 1 . Fee State Surcharge - Mechanical Total Mechanical New Curbcut Total Public Works Residential- Single Family - Storm Residential Improvement MWMC MWMC Administrative Fee SDC Administrative Fee Property Annexed 1994 Residential Sanitary MWMC Residential - Improvement Residential- Reimbursement Sanitary Sewer SDC Reimbursement Sanitary Sewer SDC Improvement Total System Development SF Residence - Willamalane Total Willamalane SDC Planning Plan Review Total Planning Address Assignment Total Permits w/o Srchg Grand Total Plan Check Type Checked By Initial Review-Res Lisa Hopper Virginia Jurasevich Engineering-Res Engineering-Res Virginia Jurasevich Job# 02-01000-01 . Page 4 of 5 Value/Quantity Fee Amount Paid On Receipt# Mechanical 09/11/2002 10578 $3.15 $61.75 Public Works 09/11/2002 10578 1 $75.00 $75.00 System Development 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 09/11/2002 10578 3,245 1 1 $915.09 $34.83 $10.00 $153.34 $-29.82 $332.86 $709.81 $160,87 $530,16 $402.96 $3,220.10 26 1 1 1 24 24 Willamalane SDC 09/11/2002 10578 1 $1,000.00 $1,000.00 Planning 09/11/2002 10578 1 $55.00 $55.00 Permits w/o Srchg 09/11/2002 10578 1 $8.00 $8.00 $5,998.35 Date Completed Comment 08/20/2002 08/28/2002 Called property owner 11 :09am 8/28/02, no answer (no answering machine). Will try and call again later. Driveway width does not meet code, 12 ft minimum and approach can not be angled, Will ask applicant for revised site plan. Tried calling Mr. Luce several time yesterday and today(8/29/02), Sent letter regarding site plan today 8/29/01. 08/29/2002 Called applicant 8/20/02 to have him bring in a revised plan drawn to scale. Structural-Res Bob Barnhart 08/22/2002 Same as plan By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance wilh the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved et of pl~ns ~ -em ~ on the site at all times during construction, f)J 1 () j ~ J C!P/ C--J . ,.' - . Job# 02-01000-01 I Date Completed - Plan Check Type Checked By Engineering-Res Virginia Jurasevich 09/04/2002 Planning-Res Ashley Deforest 08/23/2002 " . Page 5 of 5 Comment Jack and Walt of Grass Roots came into the counter 9/4/02 in the afternoon, Driveway throat minimum is 12 feet. Driveway must need ADA requirements. Applicant can "neck-down" driveway on private property, confirmed with Transportation division, Sidewalk was constructed under bp #02-00365-01. Survey division reviewed private easement for sewer, private easement falls inside public utility easement. I have included a copy of the land use decision for the minor partition with sewer conditions. IF APPLICANT NEEDS TO TAP PUBLIC INFRASTRUCTURE AND ENCROACHMENT PERMIT IS REQUIRED. I have included the encroachment permit application with the building permit, if they need the permil the applicant the cost will need to be paid at the time of submittal. -. - 1000 sq.ft. or less Each additional 500 sq. ft or portion thereof Each Manufd Home or Modular Dwelling Service or Feeder , ~.,"~ Items Cost S~, l$106.00 tib~ >iIKL..; '<gj!"" A ;lffll/;i. cf) .::::L $ 19.00 \~~!'\~. .....,""....>'. ~~:' $ 50.00 ;~~ ~~. B. Services or Feeders Installation, Alter~tion Relocation: I $709.81 I 11094- / $870.6Si CITY OF SPRINGFIa SYSTEMS DEVELOPMENT C.E WORKSHEET JOURNAL OR JOB NUMBER: 02-00976-01 NAME OR COMPANY: Jerry Moon LOCATION: 6838 Jessica Drive TAX LOT NUMBER: 18020314 tI 3000 DEVELOPMENT TYPE: SINGLE FAMILY RESIDENCE NEW DWELLING UNITS; I BUILDING SIZE: I. STORM DRAINAGE DIRECT RUNOFF TO CITY STORM SYSTEM I IMPERVIOUS S.F. I" I 'COST PER S.F. 1 I 3245,00 $0.282 RUNOFF ROUTED TO DRYWELL DESIGNED AND CONSTRUCTED TO CITY STANDARDS I IMPERVIOUSS.F. j"LCOSTPERS.F. 1..1 DISCOUNTRATE 1 I 0.00 $0.282 50% I ITEM I TOTAL - STORM DRAINAGE SDC 2. SANITARY SEWER - CITY A. REIMBURSEMENT COST: 1 NUMBER OF DFU's I ,I COST PER DFU 1 24 $22.09 B. IMPROVEMENT COST: I NUMBER OF DFU's j " I COST PER DFU l 24 $16.79 lITEM 2 TOTAL - CITY SANITARY SEWER SDC 3. TRANSPORTATION A. REIMBURSEMENT COST: I ADTTRIP RATE I xlNUMBER OF UNITS I xl COST PER TRIP 1,1 NEW TRIP FACTOR 1 I 9.57 1 $16.81 1.00 =1 B. IMPROVEMENT COST: I ADTTRIP RATE I xlNUMBER OF UNITSI xL COST PER TRIP 1..1 NEW TRIP FACTOR I I 9,57 1 I $74.l7.~ 1.00 =1 LITEM 3 TOTAL - TRANSPORTATION SDC 4. SANITARY SEWER - MWMC A. REIMBURSEMENT COST: I NUMBER OF FEU's 1,1 COST PER FEU I $332.86 B. IMPROVEMENT COST: I NUMBER OF FEU's 1.1 COST PER FEU I I $34.83 MWMC CREDIT IF APPLICABLE (SEE REVERSE) SUBTOTAL OF MWMC REIMBURSEMENT, IMPROVEMENT & CREDIT MWMC ADMINISTRATIVE FEE lITEM 4 TOTAL - MWMC SANITARY SEWER SDC I SUBTOTAL (ADD ITEMS I, 2, 3, & 4) 5. ADMIl\IISTRATIVE FEE: SUBTOTAL IXI ADM.FEERATE $3,062,98 5% SF LOT SIZE: 11061 SF =1 $915.09 =L $0.00 =,- $915.09 =1 $530,16 =L =1 $402,96 $933.12 $160,87 =1 =1 $332.86 =1 $34.83 = I ($33.60) = I $334.09 =1 $10.00 =~44.09 =1$3,062,98 =1 $153.15 TOTAL SANITARY ADMINISTRATION FEE: , 104.11 TOTAL TRANSPORTATION ADMINISTRATION FEE: 1 $49.04 Steve Templin SDC COORDINATOR 8/27/2002 DATE TOTAL SDC CHARGES = $3,216.13 \.I) ~ Q o U 0::: ~ E-< \.I) >-< c:; ~ I/, 111070' II / I I I 1091 / 1092- 1093, / / 1055 1056 / 1079 1078. . . DRAINAGE FIXTURE UNIT (DFU) CALCULATION TABLE r NUMBER OF NEW FIXTURES x UNIT EQUIVALENT = DRAINAGE FIXTURE UNITS (NOTE: FOR REMODELS, CALCULATE ONLY THE NET ADDITlONAL FIXTURES) NO, OF FIXTURES DRAINAGE ( )' UNIT FIXTURE FIXTURE TYPE # NEW # OLD x EQUIVALENT = UNITS BATHTUB (2 0) x 3 = 6 DRINKING FOUNTAIN (0 0) x I = 0 FLOOR DRAIN (0 0) x 3 = 0 INTERCEPTORS FOR GREASE / OIL! SOLIDS / ETC (0 0) x 3 = 0 INTERCEPTORS FOR SAND / AUTO WASH / ETC (0 0) x 6 = 0 LAUNDRY TUB (0 0) x 2 = 0 CLOTHESW ASHER / MOP SINK (I 0) x 3 = 3 II CLOTHESW ASHER - 3 OR MORE (EA) (0 0) x 6 = 0 MOBILE HOME PARK TRAP (I PER TRAILER) (0 0) x 12 = 0 RECEPTOR FOR REFRIG / WATER STATION / ETC (0 0) x ] = 0 RECEPTOR FOR COM, SINK / DISHWASHER / ETC (0 0) x 3 = 0 SHOWER, SINGLE STALL (0 0) x 2 = 0 SHOWER, GANG (NUMBER OF HEADS) (0 0) x 2 = 0 SINK: COMMERCIAURESIDENTIAL KITCHEN (I 0) x 3 = 3 SINK: COMMERCIAL BAR (0 0) x 2 = 0 SINK: DOMESTIC BAR (0 0) x 1 = 0 WASH BASIN (0 0) x 2 = 0 LAVATORY (3 0) x I = 3 URINAL, STALL! WALL (0 0) x 5 = 0 TOILET, PUBLIC INSTALLATION (0 0) x 6 = 0 TOILET,PRIVATEINSTALLATION (3 0) x 3 = 9 I MISCELLANEOUS DFU TYPE NUMBER OF EDD's' ( 0 - 0 ) x 20 = 0 TOTAL DRAINAGE FIXTURE UNITS =1 24 "'EDO (Equivalent Dwelling Unit) is a discharge equivalent to a smgle family dwelling unit (20 DFU's) set 81167 gallons per day MWMC CREDIT CALCULATION TABLE: BASED ON COUNTY ASSESSED VALUE I J [ 1 CREDIT FOR LAND (IF APPLICABLE) CREDIT FOR IMPROVEMENT (IF AFfER ANNEXATION) IF IMPROVEMENTS OCCURRED AFTER ANNEXATION DATE, CALCULATE CREDIT SEP ARA TEL Y YEAR CREDIT RATE PER $1,000 II YEAR CREDIT RATE PER $1,000 ANNEXED ASSESSED VALUE ANNEXED ASSESSED VALUE 1979 OR BEFORE $4.92 1990 $2.06 1980 $4.83 1991 $1.64 1981 $4.77 1992 $1.45 1982 $4.64 1993 $L31 1983 $4.47 1994 $1.13 1984 $4.30 1995 $0.97 1985 $4.09 1996 $0.82 1986 $3.78 1997 $0.63 1987 $3.41 1998 $0.41 1988 $2.98 1999 $0.22 1989 $2.52 2000 $0.04 VALUE /1000 CREDIT RATE 29.735 X $Ll3 =1 0.000 X $Ll3 =1' TO!AL MWMC CREDIT =[ $33.60 $0.00 $33.60