HomeMy WebLinkAboutPermit Building 1990-9-6
c:>
Recei.pt !I
/g2,7? C>
... RESID~TIAL-"
APPLICAT./PERMIT
225 North 5th Street
SpringfieZd, Oregon 97477
BuiZding Division
726-3753
Job Location: 5'121' :J...L':.S i Cl:L. LAn....
ASDesDors Map # I W~{)~~ Ta:J: Lot #(')1'500
Subdivision: ~O\~ T~; IL. \ \..~ , \C\ J"tJU(1-
(A,mer: 5~; L. Po-.':>~
Adib>ess: 9.0. ~ ~
CitlJ: Wl (\c...k.L~+e-r- I OIL
n
n
n
!Xl
NPT.'
u.;lO) I<:..
Phone:
~44 -its-(
&.Ii
Zip: Qi4<=t'S
Describe (l'or1(.:
Addi ticn
"\:loUh\R....D~ rf\ob~ \\e-mR..
{.or.~ \~
''3~ S 11\-
.
'1I;i.6~~
Remodel
.'-lobi le Homa
~-30-qo
Data of Appl.it:!C2ticn
Contractors
-General ~
iPlumbing '~~
i Hechanical --U
IE~~ctr~al ~^~ \
I St1peli'\H!fi~;T-1g Elect~cian
.~
Signed: ~ ;;"'_ _~,~.~
Date: ' // '?..~ ~ /.
Address
~ _. , "'" - ....." =-G -
Value '1,..V""Lo'j,.,J t' I~ :::Tl1<.J1-'
Li~c, U Bldrs Board Req.
P'hnnp
Extiices
It is \ the responsibility of the permit holder to Bee that all. inopeatio71S are made at the propel' time# that each :;ddres8 is readab!e
f1"Om the street, and that the permit card is located at the front of the property.
~Bui!.din.g Divi::io'r: approved plan shell remain on tha Building Site at all times.
PtWCSDURE FOn INSPECTION RE:OUEST:CALL 726-3769 (l'ccoT'del'J state your City designated job numbeT', job addPcss, type of inspec;icn
r>equcstcd ar:d when you /Jill be roeady for inspection, Contractors 01' Owners name and phone numbcl'. Requests receitJed before 7:00 a::'I
l..'iZ'L be rra2de the same day, requests made after 7:00 om ruiZ'L ba made the next :.JOrking day.
Rt?f1Jli.,.pn T1'I!tnpf!tir.n~
O SITE INSPECTION: To be rra2de after
excavation, but prior to set up of
fOPm8.
O UNDERSLAB PLUMBING, ELECTRICAL &
l1ECHJ!NICAL: To be made before any
I ~k is aovcred.
! - FOOTING ~ FOUNDATION: To be nrIde
!. after trenches are excavated and
I forms ape eT'ected, but prior to
I pouring ccncret~.
,0 UNDSRC.rWUND Pr.UMJJING~ SSWE:R. W.1TER.
DRAINAGE: To be made prior to fiZ-
lir.g trenahee.
o
UIIDERFWOR PWI,fBIIIG & MECHAIIICAL:
To be made prior to instaZlation of
11001' insulation or decking.
POST AND BEAM:. To be made prior to
instaZ~tion of !tOOl' insulation 01'
decking.
ROUCH PCtP.!BING. ELECTRICAL & MECH-
ANICAL: No work is to be cOL'ered
.untiL these inspections have beer.
made and approved.
FIREPLACE: Prior to placir.g facing
materiaLs and before framing inspec-
tior:.
FRAHING: Must be requested after
approval of rough plwrhing, electri-
cal & mechanical. AU roofing
bracing & chimneys, eta. mr~st be
. completed. No wark is to be con-
; ceG.led until thiD inspection has
'been made and approved.
ID
10
o
o
Your City Deaigr.atcd Job Nwnber 10:
O INSUCATION/VAPOR BARRIER INSPECTION:
To be tmde after all insulati:m tr'.d
. required vapor bCU'l'iers are. in place
.'-:;,': ::.:: but l;'efore any lathJ gypsum board or
LXlzz, covering is applied, and before
any insulation is concealed.
DRYWALC INSPECTION: To be made
after all drywLl is in place,
but prior to any taping.
O ~SONRY: Steel location, bond
beams, grouting or verticals in
accordance with V.B.C. Section
2415.
O WOODSTOVE: After installation is
completed.
o
~B & APPROACH APRON: After' forms
.~ ;;~ arected but prior .to pouring
>!07Wrete.
~DEWALK & DRII'EWr1Y: For all con-
~ crete paving ~thin street T'ight-
of-r.x:y, to be made after aLL exca-
vating complete & form work & cub-
base material in pla:!e.
D PENCE: Wher: compl~te -- Provide
~g, tes OT' movable sections through
.U,E.
STREET TREES : cJ... street
trees from approved list shall
be installed - minimum 6' high
_at..Q]anting~
O\D\CJ<6\
DEMOLITION OR MOVED BUILDIiICS
---, Sani'taPy SelJā¬l'" :!apped ::It propcrt"':i lir:.e
--.J " .\'" ,,,.,.',,./""'~l,,,jj/ljl'~'~N"I\JI":11 Ihi~.L,j,~.
~ Septi:! tank p-:.;unped and Ii lle~ _ tJi th gra::;e ~
::J Final - rfhen above items are completed
and ~hen demolition is complete or stru~-
ture moved and premises oleaned up.
J.fobi Ze Homes
~Cking and Set-~p
~umbing conne~tions -- sewer and water
~ctrical Connection - Blocking, set-up
~ d;;d plUmbing connections m'.lst be approved
before requesting electrical inspection
~ Acaessol"';j Building
~l - Aftar p:Jrches, skirting, decks,
~ etc. are completed.
.----/ CLASS A MANUFACTURED
~ HOME STANDARDS MUST
BE MET.
FINAL PLUMBItlG
All .project conditions, ouch as the instalZation of street trees, .c~~letion of the
required landscapir.a, etc., must be satisfied bcfoT'~ the BUILDING FINAL can be r2questad.
o
o
,0
o
FIlIAL MEr:HANICliL
o
FINAC BUILDINC: The Final Buildina Inspl!ction must be requeated aftezo the Pinal Plwnbina
Electrical, and Mechanical Inspectiona ha.vc been made and approved.
FIliAL ELECTRICAL
AAU, MANHOLES AND CCEANOVTS llUST BF: ACCESSIBLE. ADJUST!fENT TO BE WIDE AT NO COST TO CITY I p:1~e ! of 2
. -03~
jJOB N~lD()'1 SOLAR ~S I3-E.,Q.- L-COG~
I Zone: l. ,\.. ) \.1 _ OCCUDanCl.l G 0 Type/Cor.at: "1 Beqo~s : C)
Lot Sq, Ft., WT TYPE 1 Lot Faces - I Ener7F Sources \:- ~ T/frJe
Z of tot Coverag;: Interior I Setbacks I Heat
I P.L. House Carage Access. II Water Ypatpyo r
.II of Stories Corner INorth -:<-{j II Range t. _
TotaZ Height Panhandle lEast J II Fil'eotace
Topogrophy Cut-de-sac South h~ II Wood:;tove
IWe8t -'" II
I CHARGE I
I\Sc\')1
I I
I <LO~ I
I \~,CD I
I 'I n.crJ I
I "\0.C:50 .
I :\.6(:)
I "i~, ~I.
CHARGE I
\ ~, Cl5'"'\ I
I Where State LaLJ requires tr.at the electrical work be done by an Electrical
Contractor~ the electrical portion of' this permit shall r~t be valid until
. I, the Label has been signed by the Electrical Contractor.
\~rr) . j ~'" ~
~CO ~'2...\..J.-.\~ ~a} ~<;-~~\~,\.....\
\.fr")! \::;'\e.,C~'C\c.... ~QD\CQ., ~\ \~,~\
~\.B::::> ,. W\ \~\.:::. ~'\"\.A\~
Mechanical Permit
I ITEM SQ. FTG X
llain \---l\. ~
Value I
-:-')~, ~ \G,I
, I
I
\~
Ga:foaae
I CarDort
IAccessoru~C~
I
I
I~\..\~QI.
I S \ "i ~"6 I.
I
I \'\ fJ:) I
,'b~ I
Ft,: .
TOTAL VALUE
S.D.C.
IvaWeJ
1.5 :r
Building Permit
State Surcharge
Total Chtu'gea
I ITEM .NO., I, FEE
'I FixtU1'88 '\;J\ ~ . :
I Residential (IoothJ' " I
I Sarli tary Sewer I
I Water I
'~~~~
Plumbing Perrr:it
State Surcharge
Tota l Charam;
ITEM
I NO'1
fta. U \\
., I
I I
I I
FEE
Res. Sa.
IN~/EXtend Circuit~
I Temporary Service
I~ "'()_l\
Ele~tric~l Permit
State Suraharae
Total Charges
lITEM
I FUrnace ETU'S
I E=haus t Hood
I Vent Fan
I WoodstoiJe
NO. FEE
CIIARCE
Pernrit Issuance
I
I
I
I
~.
Mechanical Permit
State Surcharae
Total. Charaes
-- ENCROACHMENT --
Se~"rit~ Deoo3it
Storage
Maintenance
Permit
Total CharQC8
eurbcu;.
I Sid_lk
? l..\ i \ \ ~ \ \'."(.;\{"'..
\~. (,..{)
\ (".?(')
I Fen~e
I Electrical Label
IMobile Heme ~C\ .'2.';:) I
IC:C;\~L ~~c::.,\\~ \~.l5 I
I ~,~~ 5CJr-. ~ .<'2-."'\
I TOTAL AMOUNT DUE:' l R \ ' '0 \'"
Fees
Building Value & Permit
11)is permit is granted on the express condition that the sdid construction
shall~ in all re8pect8~ conform to the Ordinance adopted by the City of
Springfield, incZuding the Zoning Crdinance~ regulating the constructicn
and use of buiLdingB~ and may be suspended or revoked at cr.y time upon vio-
lation of any provisions of said Ordinances.
. Plan Check Fe,!, y. ' J ')
Data .paid:\...SiIl,'?('-I 3O-J.. \~y()
H~C"<Pt H: 18'/)~ "'\
IS<gned: t=J( nn.
Pe r m it
Plumbing
No person shall construct~ instaLZ~ aUer or change any new cr e:isting
plumbing or drainage syste~ in whole or in part~ .unless such person is the
legal possessor of a valid plumber's license~ except that a person may do
plwnbing work to property which is O1Jned, leased 01' operated by the appli-
cant.
Electrical
Permit
~,~~)\?}.
Pt:an E:xem7ner
~~G-O() '1
-
1\
J .
I HAVE CAREFULLY EXAMINED the completed application for permit, and do
hereby certify that all info:omation hereon is true and correct, and I
further certify that any ar.d all /JOrk perJom/ed shall be done in ac~or-
dance with the Ordinances of the city of Springfield, and th~ Ur~s of tho
State of Oregon pertaining to the work described herein, and that NO OCCU-
PANCY will be made of any 8truature ~ithout parmi83ion of the Building 0;-
vi~ion. I further certify that on.Ly contractors and e:rrplayees who are in
compliance with CRS 701.05E will be used on this p~oject
~k Pa~~
Si!ln.-~d V
g-lo-ctO
D.ltC