HomeMy WebLinkAboutPermit Field Test & Inspection Report 2002-1-8 MORTIER ENGINEERING, EC. STRUCTURAL BUILDING DESIGN . FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION 1245 PEARL STREET EUGENE, OREGON 97401 PHONE (541) 484-9080. FAX (541) 484-6859 TOll FREE IN OREGON 1-877-661-9959 January 8, 2002 Kevin Koontz 1650 lronhorse St Eugene, OR 97401 RE 6676 Aaron Lane - Pier Wall RevIsion - W 0 #13754-3 " As you requested, a review of the pier design specified In the engineering dated 5/30/01 was done The typical on sheet 5 specifies double king studs each side of the openings where pier design was used to resist lateral loads, Upon further consideration of the specific walls analyzed in thiS job, It was determined that a single king stud is adequate All other requirements of the pier design detail must be met, where pier design is specified In the engineering (see sheet 2) Thank you for this opportunity to be of service, If you have questions regarding thiS report, please contact m-e at 484-9080. Smcerely, Bradley R Myers, P.E .;.