HomeMy WebLinkAboutPermit Field Test & Inspection Report 2000-11-14 MORTIER ~NGINEERING, EC. STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION 1245 PEARL STREET EUGENE, OREGON 97401 PHONE (541) 484-9080. FAX (541) 484-6859 TOLL FREE IN OREGON 1-877-661-9959 November 14, 2000, Lee Edgar 1150 South 69th PI. Spnngfield, OR 97478 RE: 1128 S 69th, Sonnqfleld - Site/SoIls - W.O. #13317 All fill and unsUitable matenal has been removed to a native grade that consists of a dark brown silty clay loam with a United soils classification of ML and a plasticity index of less than 15. A maximum of 6" with a minimum of 4" of compacted crushed rock should be installed with tracked excavation equipment to protect the proposed building site in the event of Inclement weather. No extraordinary drainage or compaction is required for the treatment of expansion at this site. I hope this report is adequate for your purposes at this time. Thank you for the opportunity to be of service. If you have any questions, please do not hesitate to contact me at 484-9080. Sincerely, ..