HomeMy WebLinkAboutPermit Field Test & Inspection Report 2000-8-21
Aug-21-00 01:03P Mortier Eng & Bu;ld,ng De (541)484-6859 P.Ol
,( ~'_'<' / '? 1/
"
MORTIER
ENGINEERING, Ee,
STRUCTURAL
BUILDING DESIGN' FIRE PROTECTION
CODE CONSULTANT' PLAN CrECKING
CONSTRUCTION INSPECT,ON
'245 PEARL STREET
EUGENE, O~EGON 97401
PHONE 154'\ 464.9080' FAX (541) 484-5859
TOLL ~REE IN OREGON 1-877-861-9959
August 21, 2000
Williams General Contracting
7297 Holly St.
Springfield, OR 97478
RE. 969 S. 69th St . SPrlnafleld - Site, Same As Plan - W 0 #13040-RDR
As you requested. a site/soils investigation was performed at the above noted site. The soils
consist of a silty ioam over and Intermixed with well keyed rock. No extraordinary site
preparation needs to be performed. At the lower portion of the site approximately 10" to 12"
of compacted crushed rock has been Installed and the compaction of the gravel surface IS
greater than 95% of a standard proctor per ASTM 0698-91.
The original construction documents for 949 S. 69th may be utilized for thiS site as long as the
floor construction and foundation details do not change,
I hope this raport is adequate for your purposes at this time. Thank you for the opportunity to
be ot service. If you have any questions, please do not hesitate to contact me at 484-9080.
Very truly yours,
..n