Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2000-6-6 MORTIER l?t~q~NEERING, EC. {" ,PEARL STREET t,)GENE, OREGON 97401 PHONE (541) 484-9080. FAX (541) 484-6859 TOLL FREE IN OREGON 1-877-661-9959 STRUCTURAL BUILDING DESIGN . FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION June 6, 2000 Construction Systems 2. 40084 McKenzie Hwy Springfield, OR 97477 RE: 663 S. 7151 Street, Springfield, OR - Excavation, Fill and Compaction Inspection W.O. #12821-ROR t} As you requested, an inspection has been made during the performance of the excavation and placement of gravel fill on this site in preparation for the construction involving foundation repairs for the existing residence. The excavation involved removal of surface organic soil and other unsuitable material and the placement of an 8" t012" layer of crushed rock in accordance with our standard procedures. The compacted surface of the crushed rock is adequate for a foundation bearing capacity of 1500 psf, which is adequate to support the existing conventional wood frame residence. The compaction ofthe gravel surface is greater than 95% of a standard proctor per ASTM 0698-91. \ I hope you find this report adequate for your purposes at this time. Thank you for this opportunity to be of service. If you have further questions, please do not hesitate to contact me at 484-9080. Very truly yours, ,. Bradley R. Myers, P.E. RORlmm Excavation 2 /\