HomeMy WebLinkAboutPermit Field Test & Inspection Report 2000-6-6
MORTIER
l?t~q~NEERING, EC.
{" ,PEARL STREET
t,)GENE, OREGON 97401
PHONE (541) 484-9080. FAX (541) 484-6859
TOLL FREE IN OREGON 1-877-661-9959
STRUCTURAL
BUILDING DESIGN . FIRE PROTECTION
CODE CONSULTANT. PLAN CHECKING
CONSTRUCTION INSPECTION
June 6, 2000
Construction Systems 2.
40084 McKenzie Hwy
Springfield, OR 97477
RE: 663 S. 7151 Street, Springfield, OR - Excavation, Fill and Compaction Inspection
W.O. #12821-ROR
t}
As you requested, an inspection has been made during the performance of the excavation
and placement of gravel fill on this site in preparation for the construction involving
foundation repairs for the existing residence. The excavation involved removal of surface
organic soil and other unsuitable material and the placement of an 8" t012" layer of
crushed rock in accordance with our standard procedures. The compacted surface of the
crushed rock is adequate for a foundation bearing capacity of 1500 psf, which is adequate
to support the existing conventional wood frame residence. The compaction ofthe gravel
surface is greater than 95% of a standard proctor per ASTM 0698-91.
\
I hope you find this report adequate for your purposes at this time. Thank you for this
opportunity to be of service. If you have further questions, please do not hesitate to
contact me at 484-9080.
Very truly yours,
,.
Bradley R. Myers, P.E.
RORlmm
Excavation 2
/\