HomeMy WebLinkAboutPermit Field Test & Inspection Report 2000-12-13
1245 PEARL STREET
EUGENE, OREGON 97401
PHONE (541) 484-9080. FAX (541) 484-6859
Tall FREE IN OREGON 1-877-661-9959
STRUCTURAL
BUILDING DESIGN . FIRE PROTECTION
CODE CONSULTANT · PLAN CHECKING
CONSTRUCTION INSPECTION
r- MORTIER
3NGINEERING, EC.
December 13, 2000
Emmanuel Construction
84591 Pheasant Lane
Pleasant HIli, OR 97455
RE 5545 Glacier. Sorinafleld - Site/Solis Inspection - W 0 # 13381 RDR
As you requested an Inspection was performed on December 12, 2000 at the above named site.
The excavated site consisted of 12" of top sOil over an ashlsandstone matenal. The design for the
site IS as follows
Excavate through organics to firm top sailor ash stone matenal.
Slope bench cuts to facilitate drainage
Install maximum of 6" compacted crushed rock on all excavated areas to protect the
excavation dunng Incllmate weather.
I hope you fInd this report adequate for your purposes at thiS time. Thank you for this opportunity
to be of service If you have further questions, please do not hesitate to contact me at 484-9080.
Very truly yours,
Bradley R Myers, P E