HomeMy WebLinkAboutPermit Field Test & Inspection Report 1998-6-15 . . - , STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION ~ORTIER WNGINEERING, P.c. PO. BOX 139 . 1245 PEARL STREET EUGENE, OREGON 97440 PHONE (541) 484.9080 . FAX (541) 484-8859 June IS, 1998 Leslie Polifroni 303 Crocker Ln. Eugene, OR 97404 RE: fiRRR Ivv SI S~ri'lgfi"ld OR - P,,1JllitjI9R0441 - rnm~"dinn T"'I - W.O. #10926-KMP As you requested, a compaction inspection of the gravel under the proposed foundation has been performed on this site in preparation of the construction involving foundations for the proposed residence. The excavation involved the placement of3/4" minus crushed rock over the top of 3 Yz" minus crushed rock. The compacted surface of the crushed rock is adequate for a foundation bearing capacity of I 000 psf. The underlying soil conditions, site drainage and foundation were not designed or rcvicwed by Mortier Engineering, P.c. The compaction of the gravel surface is greater than 95% of a standard p:-octor, per ASTM D698-91. (See attached data sheet). . I hope you find this rcport adequate for your needs and purposes at this time. Thank you for this opportunity to be of service. Please contact me if you have further questions at 484-9080. Very lrll! y yours, Owen Grover, P.E. OLG/jjh cng.compact.sld. .' " ~ . e .' "MORTIER .NGINEERING, P.c. p.o. BOX 139 . 1245 PEARL STREET EUGENE, OREGON 97440 PHONE (541) 484-9080 . FAX (541) 484-6859 STRUCTURAL BUILDING DESIGN -FIRE PROTECTION CODE CONSULTANT _ PLAN CHECKING CONSTRUCTION INSPECTION FIELD UNIT WEIGHT - SAND CONE METHOD Per ASTM D 1556 TEST NUMBER: TEST LOCATION: (.; DATE OF TEST: '" - \'1. - '\5 W.O.# Ie", '2.<0 TEST BY: t.f ,,; " 1 - ~e.u s.1-\~'t.? o..0"'~,< ~I'- MATERIAL TESTED (By visual observaUon): UNIT WEIGHT OF SAND USED FOR THIS SAMPLE P. (sand) = 18. (;) \"'_~ . VOLUME OF CONE 01,) = 0,0389 ft^3 e FIELD TEST DATA Initial Weight of Jar + Sand (W,) \ 0 \1, I 4- . 0 r.l- Weight of Jar + Sand after test (W.) U Ik. 1, ~ 'n.. Volume of hole, W, - W, - V, = V, P. Weight of soil sample (W,) = r.::) .D\"i~ Moist unit weight of soil Pm =)fb. = V, 'Z. \ In ;:l., . +- c>Z- \ 'to"" \",<:"<;::' Moisture content of sample, W% = fweicht moist) - fweicht drY) X 100 (weight dry \.-' '/. Pm Dry Unit Weigh of Soil P. = 1 + W% 100 \1.A-"S r MOISTURE CONTENT weight of jar net weight Wet weight \ 31:::, \?"::> Ih = C.fZ..1J5\....h:~T~ QoA.Jl..:?:f 12..0') \\ 5" J \Z-.. c.. ,,,- Co> v",:l:- e. Dry weight ~/A "_ Notes: or \0 = '-o&(..,~ '717..-C1AL- . . ., .,MORTIER ~~0~~~:5:~~~R~~ P.C EUGENE, OREGON 97440 PHONE (541) 484-9080 . FAX (541) 484-6859 STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION FIELD UNIT WEIGHT - SAND CONE METHOD Per ASTM D 1556 TEST NUMBER: '2. TEST LOCATION: N DATE OF TEST: ~ - 1"1.. - '\6 W.O.# \ 0" tc..:. TEST BY: ~r ;'1 " I,\- - ce.us~= CR'-'''''la.~'l \?.:>"-~ MATERIAL TESTED (By visual observation): UNIT WEIGHT OF SAND USED FOR THIS SAMPLE p, (sand) = iCt. C> \<:.~ VOLUME OF CONE 01,) = 0.0389 ft^3 . FIELD TEST DATA Initial Weight of Jar + Sand 0/11,) It> \'0 \.,.~ "'- U:, ,.., \ I . '3 .... Weight of Jar + Sand after test 0/11,) Volume of hole, W, - W, - V, = V, p, Weight of soil sample 0/IIJ = O-Dl,?1 Moist unit weight of soil Pm = W, = V, \ \ \-, \4-.0 '""l- 1\ C\ p~ Moisture content of sample, W% = .Iweioht moist) - fweiaht drv) X 100 (weight dry <;. \ '/, Pm Dry Unit Weigh of Soil Pd = 1 + W% 100 \ \..." P~-I=' -, MOISTURE CONTENT e. weight of jar net weight Wet weight \\8 Ie:-, = \o~o. ) Dry weight II"? \~ = '10 a, J Notes: L-o-rs ~l" ,,,,,>-11:."'-, 3/4"_ c.ILU51-H:::1-, c;5I0A~-{ =c...',:;-- O\ll~~ L"" ",",,-1-fZ,S Sj"\=-C.IJ>..t.- . .