Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2001-5-4 l"~~;l Information ~.,. .To Build On Engineering. Consulting. Testing DAILY FIELD REPORT Date Performed' May 4,2001 Mr Mike Ferchland 327 South 58th Street #C Spnngfleld, OR 97478 Report Number: 722-10168-2 Client Project Name: Ferchland Residence Project Location: 6947 Ivy Street Spnngfleld, Oregon PO No' Type of Structure. Type of Inspection: Permit No.: Weather: 00-01441-01 Overcast Walls Reinforcing Steel Reinforced Concrete Field Observations and Comments Performed visual Inspection of reinforcing steel In the following locations Stryrofoam block walls at living area top ot' footing to 6' garage walls top of footing to 5' and Intenor wall between garage and living area top of footing to 4' Reinforcing steel was checked for grade, Size, lap, placement and clearances where applicable R,elnforclng steel was secured uSing plastic posltroners. As directed by owner/contractor, contInuous inspectIon dunng placement of concrete was not required Cast one set of three (6x12) concrete test cylinders Note As per conversation between owner Mike Ferchland and Tim with Great House Design (2) 5/8" anchor bolts could be placed at 32" on center max at floor ledger To the best of our knowledge, the work Inspected above was In accordance wIth the bUilding department approved design drawings, speCifications and applicable workmanship provISions of the Uniform BUilding Code Contractor was 'd to notlfy,our office when additional services are needed Tvoe of Material Concrete Supplier Morse Bros Mix# 7 Slump 51/2" Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) Number of Samples Total Yardage Placed Inspector, David Smith, ICBO# 0877340-88 71 73 7 00 AM 3000 3 (6x12) 30 If you have any questions regarding this report, please feel free to contact us at 541-746-9649 ,\~"\92027-2 fo~ <~ ~~ A '\?~ ~ ;jf'I p ~ 14 ~ f1 If r POOl ~ \~ llrq;f$ rui <9< ~o 9St> € Z \''''- \; Respectfully Submitted, ProfeSSIOnal ServIce Industnes, Inc ~~1 V C~f Raymond V Allpertl Department Manager ..2lty of Springfield _ THIS REPORT is PROViDED FOR TI-IE iNFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMiSSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED Professional Service Industries, Inc. 1040A Shelley St . Springfield, OR 97477. Phone 541/746-9649. Fax 541/746-7163