Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 1994-2-22 ~ . . Schaudt, Stemm & Wild,lne. CONSULTING ENGINEERS, SURVEYORS ANO PLANNERS 388 High Street S03t48S,8383 Eugene. Oregon 97401 #- 93/9ok FAX S03t485-3S82 Job *" 94-4358-7 February 22, 1994 City of Springfield Building Division 222 N. 5th St. Springfield, Or. ~7477 ATTN: Don Moore, Building Inspector -- RE:'-New"House' at-6737-Ivy-Str,eet, Springfield,_O",.___ Howard Konold, Contractor We specified concrete with f'c=3000 psi in 28 days for durability. However, for compressive strength f'c= 2500 psi in 28 days is acceptable for structural purposes. The Contractor ordered f'c= 3000 psi concrete to be delivered and he has documentation to show that the concrete supplier provided this strength by design. Sincerely, ~P:'~~ RALPH W. WILSON, P.E. SCHAUDT, STEMM & WILD, INC. cc: Howard Konold RWW/klf