HomeMy WebLinkAboutPermit Building 2002-5-28
;;
SPRINGFIELD
.-..: -
225 Fifth Street
Springfield, OR 97477
-,
.
I Job# 00-01441-01 I
Page 1 of4
CITY OF SPRINGFIELD, OREGON
RESIDENTIAL PERMIT
City Of Springfield
Community Services Division
Building Safety
Job Number: 00-01441-01
Office: 726-3759
Inspection Line: 726-3769
Location Of Proposed Site: 6947 Ivy St Spr
Assessors Map#: 18020223
Lot: 58 Block: Addition:
Owner:
Address:
Tax Lot #: 07500
Subdivision:S.HILLS NORTH
Michael Ferchland
Phone Number: 541-746-2248
City/State/Zi'P:rE~pfjngfield'JOR,9,7,4Z;~ullb" yOu tv
fOllow rules anaotAd c'.., , ~ .
New Notification CeValue:, $243,2-13'gon Utility
in OAR 952.00 mer. I hose rules are set forth
1-0010 through OAR 952-001-
0090:..Youmay obtain COPies of thA .. ,Io~ h"
--..."" ''''''''''I/ter. (l'Iote: the tel h -
R . '6'.lmt,h-'#'orE .. t' D t ep",2ne
egls"a lon' x~lra !9.n] J!..'il;y Notif,'c~~I]~
Center IS 1-800-332-'34.541-746-2248
- .
Scope Of Work: Single Family Residence
697 S 70th St
Contractor Type
Plumbing Contr
SFR
Contractor
Michael Ferchland
697 S 70th St, Springfield, OR 97478
Office Use
Quad Area: 4RSE Land Use: Single Family Dwelling # Of Buildings: 1
# Of Units: 1 Zoning Code: LDR Occupancy Group: Dwelling
Constr. Type: (VN) Wood Frame Bedrooms: 3 NOTICE: Heat Source: Forced Air Gas
Water Heater: Gas Range: ElectriqHIS PERMIT SHM.l{; E~ll\t'iF T~WnRIC
To request an inspection call the 24 hour recording at 726-3769. A~UmfHORIRUN~IT.<<l~~~~~RNOT
a.m. will be made the same working day, inspections requested a 1 ~1Plm4A1~H1lJ
working day. I O.
Site
Verify Ground Rod
Footing
Foundation
Post and Beam
Floor Insulation
Ceiling Insulation
Shear Wall Nailing
Framing
Wall Insulation
Drywall
Special
Final Building
Temporary Power
Rough Electrical
Required Inspections
I Buildinll I
- To be made after excavation but prior to setting forms.
-Install ground rod at footing, and call for inspection in conjuction with footing andlor foundation ir
-After trenches are excavated.
-After forms are erected but prior to concrete placement.
-Prior to floor insulation or decking.
- Prior to decking.
- Prior to cover.
- Before covering sheathing with finish materials.
- Prior to cover.
- Prior to Cover
- Prior to taping.
-See Plan Review andlor Inspectors Notes, or prior to cover if applicable.
- When all required inspections have been approved and the building is complete.
I Electrical I
-Approval required prior to SUB energizing pole.
- Prior to cover.
D
::;::
-< -<
0:;0
;::ODD
rr1~Z
C"") nl c,t'J
0" **
o ..~..
D I'.J:DO
OJ -<........
::c ." I
f-lC":) NO
rr1::r::-.,JCOO
:;OD(J1 0
...Z.o".J""O
om- 01',:)
0rr100U"l
I-l... 0/".,)0"-
Street Improvement: Fully Improved
Curb Cut?0 Improvement Agr.?D
San Sewer Depth (Ft): 6 4
Storm Sewer Available? 0
Special Req.:
Security Required:
Bond Begin DateTime: 00/0010000 00:00:00.
Special Instructions:
Other Utilities:
Project Supervisor:
,
Electrical Service
Final Electrical
Underfloor Plumbing
Underfloor Drain
Rough Plumbing
Water Line
Sanitary Sewer Line
Storm Sewer Line
Sanitary Sewer Cap
Perimeter Foundation
Drains
Final Plumbing
Underfloor Mechanical
Rough Gas
Rough Mechanical
Gas Service
Final Gas
Final Mechanical
SW-Curbslde
CC-Standard
,
.
I Job# 00-01441-01 I
Required Inspections
I Electrical I
-Must be approved to obtain permanent power.
-When all electrical work is complete.
Page 2 of 4
I Plumbing
. Prior to insulation or decking.
. Prior to cover or placement of concrete.
- Prior to cover.
-Prior to filling trench.
-Prior to filling trench.
-Prior to filling trench.
.Capped within five feet of the property line and capped with an approved material as required b~
-After gravel and filter cloth is installed, but prior to backfill.
-When all plumbing work is complete.
I Mechanical
- Prior to insulation or decking.
-After line is installed and capped if not attached to an appliance.
- Prior to cover.
-After line is installed and line has been connected to a minimum of one appliance. Pressure tes
-When all gas work is complete.
-When all mechanical work is complete.
Public Works I
-After forms are erected but prior to placement of concrete
-After forms are erected but prior to placement of concrete
Sidewalk Type:
Additional ROW?
Size Of Line (in):
Downspouts/Drains:
Enchroachment Permit:
San Sewer Tee (in):
Bond End DateTime:
Curbside - 5'
o
8
To Curb and Gutter
6
00/0010000 00:00:00'
Types Of Warning Devices Reqd.
.
,
Zoning: LOR
FloodPlain? 0 Wetlands? 0
Journal numbers
1: 2:
Comments:
Planner: Ruth Klein
Urban Growth Boundary?O
Quantity Of Fill:
Supplier:
Drainage:
Floodway FEMA: nla
I Job# 00-01441-01
Overlay District:
# of Street Trees:
.
3:
Additional Requirements:
Glenwood Area? 0 Required Attachments:
Source Locn:
Material:
Construction Types:(VN) Wood Frame
Occupancy Groups:Dwelling
# Of Buildings: 1
# Of Bedrooms: 3
Handicap Access? 0
rArea (Sq. r, ,1)
Main: 2943 Accessory~264
Fee
Residential Plan Check
Total Plan Check
Building Permit
State Surcharge For Building Permit
Building Administrative Fee
Total Building
Wiring Footage 1,000 Sq Ft or Less
Wiring Footage Each Add'l 500 Sq Ft
Temporary: 200 Amps or Less
State Surcharge - Electrical
Administrative Fee - Electrical
Total Electrical
Minimum Plumbing Permit Fee
State Surcharge - Plumbing
Four or More Bathrooms
Administrative Fee - Plumbing
Total Plumbing
Hood and Exhaust
One to Four Outlets
Minimum Mechanical Permit
Administrative Fee - Mechanical
Less than 100,000 BTU
Vent Fan to One Duct
Gas Fireplace
Flood Plain FEMA: n/a
Page 30f4
Land Use: Single Family Dwelling
Pave Driveway? 0
# Of Stories: 2 Height (feet): 30
Current Units: Proposed Units:1
Census Code: New SF - attached
Total:4207
Paid On Receipl#
Plan Check
09/25/2000 3301
Buildina
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
Electrical
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
Plumbina
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
Mechanical
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
Value/Quantity
I
Fee Amount
243,213
$492.05
$492.05
243.213
$757.00
$52.99
$22.71
$832.70
1
8
1
$85.00
$120.00
$40.00
$17.15
$7.35
$269.50
1
$.00
$13.48
$192.50
$5.78
$211.76
1
1
$4.50
$2.00
$.00
$1.05
$6.00
$15.00
$4.50
1
5
1
,
Fee
Dryer Vent
Mechanical Issuance
State Surcharge - Mechanical
Total Mechanical
New Sidewalk
New Curbcut
Total Public Works
Residential - Single Family - Storm
Sanitary Sewer
Residential Transportation
Residential Improvement MWMC
MWMC Administrative Fee
SDC Administrative Fee
Properly Annexed 1994
Residential Sanitary MWMC
Total System Development
S.F. Residence - Willamalane
Total Willamalane SDe
Deposit
Total Deposit/Copies/Mis
Grand Total
Plan Check Type
Checked By
Initial Review-Res Bob Barnhart
Engineering-Res Steve Templin
Planning-Res RK
Structural-Res Don Moore
Structural-Res Don Moore
Structural-Res Don Moore
Job# 00-01441-01
Paid On Receipt#
Mechanical
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
. Page 4 of 4
Value/Quantity Fee Amount
1 $3.00
$10.00
$2.45
$48.50
90 $60.00
1 $60.00
$120.00
2,850 $683.94
36 $1,794.96
1 $507.82
1 $24.33
1 $10.00
$164.07
24 $-25.48
1 $285.91
$3,445.55
1 $1,000.00
$1,000.00
750 $750.00
$750.00
$7,170.06
Public Works
11/03/2000 3705
11/03/2000 3705
System Development
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
11/03/2000 3705
Willamalane SDC
11/03/2000 3705
Deposit/Copies/Mis
OS/28/2002 9256
Date Completed
Comment
09/26/2000
1 0/03/2000
1 0105/2000
1 0106/2000
Contacted Designer & Engineer for revised
beam hanger info. required.
Contacted Engineer again for required
information.
10/30/2000
11/02/2000
By signature, I state and agree, that I have carefully examined the completed application and do
hereby certify that all information hereon is true and correct, and I further certify that any and all work
performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of
the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made
of any structure without permission of the Community Services Division. Building Safety. I further
certify that only contractors and employees who are in compliance with ORS 701.055 will be used on
this project.
I further agree to ensure that all required inspections are requested at the proper time, that each
address is readable from the street, that the permit card is located at the front of the properly, and the
ap~,? gain yhe site at all times during construction. 114-'1 '2 tf. 'Z.CJOz.
,