Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-6-29 (2) l~'hIlli:!P11nformation 1 ,R~: .ToBuildOl1 /l!ngJ HI.I, .,r1Itg · C.", -.1' c6It:lns1 · TeIri:lIJfl €lient. I' Address: Ms Julie Daniels Bnng Recycling PO Box 885 Eugene, Oregon 97440 p~~ PI~cement Data , , t" BUilding # 8 line A to A 2 from 1 to 4 , , : l : I _.1 j , . M'atenal tocatlOn Sampled At ~ , :A'1-38 I;ieslgn Strength (pSI): ..." ,.. " 11 I , j' I~Yilnder No Date Cast T:lcket No 12324634 :;' ';06-1311 } l , ~ ~; i I :: . : :06-1312 ,,, ,l I' "06-1313 l: ; 4f ;11:(i):6-1314 ,;) 'I, ~; , ! }J~ .96-1315 " ..1 'j '. 05/30/06 I Date Rec'd 05/31/06 MIX No Weather 2430NE7200 Clear required 3,000 Test Date Field Cure (days) Lab Cure (days) Age (days) 6/6/2006 6/6/2006 6/27/2006 6/27/2006 6/27/2006 7 7 28 28 28 1 ~ SPRINGFIELD OFFICE COMPRESSION REPORT 1040 - A Shelley Street Sprmgfield, Oregon 97477 (541)746-9649 - (541)746-7163 fax June 29, 2006 COM 2006-00202 Project No : 722-60111-25 ProJ Name. Planet Improvements Center, Ph I Location: 4446 Franklin Blvd Spnngfleld,Oregon Date: B p, No.: P.O No.: Cast By: David Smith Yardage 2 20 Slump (In) ASTM C143 _Max Aggr Size Air Content ASTM C231 Air Temperature (F) Matenal Temp (F) ASTM CI064 Max Temp (F) MIn Temp (F) Specimen Size Unit Weight (pct) ASTM C138 Time Cast 6 00 AM Additives AEA Results Reported To Field Test Data 51/4" 3/4" 54% 46 61 726 535 6 x 12 . J Load Total Supplier Morse Bras Cunng Conditions ASTM C31 Contractor 6 6 27 27 27 Compressive Strength Data ASTM C39 placed 3,000 . , Diameter or Cross Sect Area Cylinder WT Comp Strength Capping Method DimensIons Max Load (Ibs ) Fracture Type ** Test TIme (Inches) (s I) (Ibs) (pSI) C617 -03 C1231-03 596 2792 274 76,880 2,750 3 8 55 AM X 600 2827 277 82,555 2,920 2 901 AM X 602 2846 278 112,010 3,940 2 10 03 AM X 600 2827 277 110,795 3,920 3 9 37 AM X 601 2837 278 111,295 3,920 2 9 41 AM X ";1' - Cone (both ends) 2 - Cone/Vertlcai Cracks (one end) I Remarks: , c:f :3 - Columnar 4 - Diagonal wino craklng at ends c TBG Architects & Planners City of Spnngfleld Morns Kielty Construction Morse Bros 5 - Side fractures (at top of bottom) 6 - Top fractures (same as #5 but end of cylinder IS pOinted) Res')r',ctfu lIy /t ~ ~~~ted, Pro b ~O{JftJr\S Industries, Ine Ste~~n E Wilder Laboratory Supervisor THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL, IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES