HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-7-20 C-~- 2.1)2 l-'!:-' Information ~~. .To Build On Engineering. Consulting. Testing DAILY FIELD REPORT Date Performed. July 20, 2006 Report Number 722-60111-44 Chent Ms Julie Daniels Bring Recycling POBox 885 Eugene, OR 97440 PrOject Name: Bring Recycling Bldg # 7 (drive thru) 4446 Franklin Blvd Springfield, Oregon PrOject LocatIOn' P.O No Type of Inspection. High Strength Bolts Permit No . Weather' Clear Field Observations and Comments Arrived on-site to perform a speCial Inspection on the A325 high strength bolts In the primary roof and portal connections Bolts were checked for "snug tight" condition and marked for the final 1/3 turn to be performed and Inspected In the future To the best of our knowledge, the work Inspected above was In accordance with the bUilding department approved deSign draWings, specifications and applicable workmanship provISions of the International BUlldln~ Code Inspector Chns Thomason, ICC# 5069949-85 If you have any questions regarding this report, please feel free to contact us at 541-746-9649 Respectfully Submitted, prore""JIJCdustnes. In' Chnstopher Thomason Structural Steel Field Supervisor c TBG Architects & Planners City of Springfield MOrriS Kielty Construction HOHBACH-LEWIN, INC THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERViCE INDUSTRIES, IS PROHIBITED Professional Service Industnes, Inc. 1040A Shelley St . Spnngfleld, OR 97477. Phone 541/746-9649. Fax 541/746-7163