HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-7-20
C-~- 2.1)2
l-'!:-' Information
~~. .To Build On
Engineering. Consulting. Testing
DAILY FIELD REPORT
Date Performed.
July 20, 2006
Report Number
722-60111-44
Chent
Ms Julie Daniels
Bring Recycling
POBox 885
Eugene, OR 97440
PrOject Name:
Bring Recycling Bldg # 7 (drive thru)
4446 Franklin Blvd
Springfield, Oregon
PrOject LocatIOn'
P.O No
Type of Inspection.
High Strength Bolts
Permit No .
Weather'
Clear
Field Observations and Comments
Arrived on-site to perform a speCial Inspection on the A325 high strength bolts In the primary roof and portal
connections Bolts were checked for "snug tight" condition and marked for the final 1/3 turn to be performed and
Inspected In the future To the best of our knowledge, the work Inspected above was In accordance with the bUilding
department approved deSign draWings, specifications and applicable workmanship provISions of the International
BUlldln~ Code
Inspector Chns Thomason, ICC# 5069949-85
If you have any questions regarding this report, please feel free to contact us at 541-746-9649
Respectfully Submitted,
prore""JIJCdustnes. In'
Chnstopher Thomason
Structural Steel Field Supervisor
c TBG Architects & Planners
City of Springfield
MOrriS Kielty Construction
HOHBACH-LEWIN, INC
THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERViCE INDUSTRIES, IS PROHIBITED
Professional Service Industnes, Inc. 1040A Shelley St . Spnngfleld, OR 97477. Phone 541/746-9649. Fax 541/746-7163