HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-7-10 (2)
l"'~;l InfomUltion
~~. .ToBuildOn
Engineering. Consulting · Testing
DAILY FIELD REPORT
Date Performed: July 10,2006 Report Number. 722-60170-13
Client. Mr Dennis Dille Project Name: Chip Handling Project
Weyerhaeuser
1300 SW 5th Ave, SUite 500 Project Location: 785 North 42nd Street
Portland, OR 97201 Spnngfield, Oregon
P.O. No.: Permit No.: COM~Ov; --00:3 DO
Type of Structure: Weather: Overcast
Type of Inspection: Reinforcing Steel
Field Observations and Comments
'Performed continuous Inspection of reinforcing steel In the follOWing locations wheel ring foundation sections 5 through
8 for pours 3 and 4 see detail A/50040 Reinforcing steel was checked for grade, Size, lap, placement, and clearances
where applicable Reinforcing steel was secured uSing tie wire and supported on concrete doble blocks Reinforcing
steel was placed In accordance with approved design drawings, speCifications, and latest reVISions dated May 10, 2006
Note not all forms are In place, clearances Will be checked prior to pour To the best of our knowledge, the work
Inspected above was In" accordance With the bUilding department approved design drawings, speCifications and
applicable workmanship proVISions of the International BUilding Code Contractor was asked to notify our office when
additional services are needed
Inspector: David Smith, ICC# 0877340-88
If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649
c City of Springfield
Solarc Architecture - Galen Ohmart
Broad Base - Roy Gray
Branch Engineering - Rene Fabricant
THIS REPORT IS PROVIDED FOR THE INFORMA TION OF THE CLIENT ONL Y THE REPROOUCTION OF THIS REPORT, BY ANY METHOD, ANO ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES IS PROHIBITED
ProfeSSional Service Industnes, Inc' 1040A Shelley St . Spnnglield, OR 97477' Phone 541f746-9649' Fax 541f746-7163
---