Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-7-11 l '!~;ll1ifonnation ~.,. .To Build On Engineering. Consulting. Testing DAilY FIELD REPORT Date Performed: Client: July 11, 2006 Mr 'Denrlls Ehlle Weyerhaeuser 1300 SW 5th Ave, SUite 500 Portland, OR 97201 Report Number: 722-60170-16 Project Name: Chip Handling Project 785 North 42nd Street Spnngfleld, Oregon Project Location: P.O. No.: SCH-00019 Weather: Overcast Type of Inspection: Reinforcing Steel Reinforced Concrete Field Observations and Comments , Performed preliminary Inspection of reinforCing steel In the following locations on dump truck foundation reclalmer wheel nng section 5 and 6 and north truck dump foundation details Band C on 50068 and B-50060 Preliminary rebar Inspection ReinforCing steel was checked for grade, Size, lap, placement, and clearances where applicable. Reinforcing steel was placed In accordance With approved design drawings, specifications, and latest reVISions dated July 10, 2006 at wheel ring Performed Visual inspection dUring placement of concrete In the above locations Concrete was placed by truck chute and mechanically consolidated Cast one set of four (6x12) concrete test cylinders Note verified rebar clearances pnor to concrete pour on wheel ring WIll perform final inspection on rebar at north truck foundation pnor to pour To the best of our knowledge,-the work Inspected above was In accordance-with the bUilding department approved deSign draWings, speCifications and applicable workmanship proVISions of the International BUilding Code Contractor was asked to notify our office when additional services are needed Ty~p of Material Concrete #1 Supplier Morse Bros Mix # 2440N070RO Slump 5" Air Content 4 2% Art:lpient Temperature 75 Material Temperature 75 Ti!'Tle Placed 10 45 AM Design Strength (psi) 4000 Number of Samples 4 (6x12) Total Yardage Placed 80 Inspector: David Smith, IcC# 0877340-88 If you have any questions regarding this report, please feel free to contact us at 541-746-9649 Respe tfully Submitted, I Prafe lonal S~stnes, Inc __ fr~\-- .er Tran tment Manger ~ c City of Spnngfleld Sol arc Architecture - Galen Ohm art Broad Base - Roy Gray Branch Englneenng - Rene Fabricant THIS REPORT IS PROVIDED FOR THE INFORMA TION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED ProfeSSional Service Industries, Inc' 1040A Shelley St . Springfield, OR 97477' Phone 541/746-9649' Fax 541/746-7163 -----