Daily Field Report
Client: Ms Knsten Karle Project. The Royal BUilding Date: 11-1 5-06
St Vincent de Paul 501 Main Street Project No : 2067145
POBox 24608 Springfield, Oregon Report No : E14696
Eugene, Oregon 97402 Inspector: E Marjama
10 No.. 5235029
ICC
Inspection of' Reinforced Concrete Weather: Overcast Continuous Inspection: 0
Contractor: Melli Construction BP No.: COM2006-00624 Periodic Inspection: 0"
Performed final inspection on the reinforcing steel for footing to second floor walls for
elevator shaft and first to second floor walls for east and west stairwells and columns at
Intersection of lines F1, F2, F3, F4, F5, F6, E1, E2, E4, E5, E6, 04, 05 and 06
Reinforcing steel was checked for grade, Size, lap, placement and clearance Note
preliminary Inspections were performed on 10-30-06, 11-07-06 and 11-10-06 pnor to
form closure ReinforCing steel was secured With tie-Wire Observed the placement of
960 cu /yds of MBI 4000 pSI concrete (MIx 24F4NEA2MO) In areas listed above
Concrete was placed by pump and was mechanically consolidated Cast one (1) set of
four (4) 6" X 12" concrete test cylinders from load 3 Derrick (Melli Construction) was
notified of on-site test results slump 5 3/4", concrete temperature 63F, air temperature
49F
To the best of our knowledge, the work Inspected was In accordance With plans dated
08-30-06 and applicable workmanship prOVISions of the I B C , except If noted above
Contractor was asked to notify our office when additional services are needed
,-/
ReViewed By
/jllldJa/
tViichael L J:;~r
Technical Manager
c Melli Construction - Curt Melli (e-mail)
Melli Construction - Curt Dawson (e-mail)
Bergsund Delaney Architecture & Planning (e-mail)
Hohbach-Lewln Structural Engineers (e-mail)
, City of Spnngfleld
MLMJw
This report andlor enclosed test data IS the confidential property of the client to whom It IS addressed and pertains to the specific
process and/or matenal evaluated As such, Information contained herein shall not be reproduced In part or full and/or any part
thereof be disclosed Without FEI Testing & Inspection, Inc 's wntten authonzatlon
7ffJ NVV Cane/I Avenue CorvalliS, Oregon 97330 phone (541) 757-4698 fax (~1) 757-2991
29540 B AIrport Road Eugene, Oregon 97402 phone (541) 684-3849 fax (541) 684-3851