HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-10-31 ~pp~ ~#rtl II1oill/(IUI m ~~'llIHIIlliI Page 1 of 1 Geotechnical & Construcbon SeI'VlCSS Daily Field Report Client. Ms Knsten Karle ProJect. The Royal BUilding Date 10-31-06 St Vincent de Paul 501 Main Street Project No . 2067145 POBox 24608 Spnngfleld, Oregon Report No.. E14570 Eugene, Oregon 97402 Inspector. E MarJama 10 No' 5235029 ICC Inspection of: Reinforced Concrete Weather' Overcast Continuous Inspection' 0 Contractor: Melli Construction BP No.: COM2006-00624 Periodic Inspection: 0 Performed final Inspection on the reinforcing steel for penmeter stemwalls A preliminary inspection was performed on 10-30-06 (ref FEI report no E14545) Reinforcing steel was checked for grade, Size, lap, placement and clearance Reinforcing steel was secured with tie-Wire Observed the placement of 10 5 cu /yds of MBI 3000 pSI concrete (MIx 30-5PV) In perimeter stemwalls Concrete was placed by pump and was mechanically consolidated Cast one (1) set of four (4) 6" x 12" concrete test cylinders Curt Dawson (Melli Construction) was notified of on-site test results slump 5", concrete temperature 63F, air temperature 40F To the best of our knowledge, the work Inspected was In accordance with plans dated 06-29-06 and applicable workmanship provIsions of the I B C , except If noted above Mr Dawson was asked to notify our office when additional services are needed Reviewed By fl1.:I,fJ~ Michael L Meyer Technical Manager c Melli Construction - Curt Melli (e-mail) Melli Construction - Curt Dawson (e-mail) Bergsund Delaney Architecture & Planning (e-mail) Hohbach-Lewln Structural Engineers (e-mail) City of Springfield MLMJw This report and/or enclosed test data IS the confidential property of the client to whom It IS addressed and pertains to the specific process and/or materral evaluated As such, information contained herein shall not be reproduced In part or full and/or any part thereof be disclosed Without FEI Testing & Inspection, Inc 's wrrtten authorrzatlon 7ffJ N-N Come/I Avenue Cavalhs, C,tyUll 97330 phone (541) 757-4698 fax (541) 757-2991 29540 B Anoort Road Euaene C tuul I 97402 ohone (541 )684-3849 fax (541 ) 684-3851