Compressive Strength of Concrete
(ASTM C 39)
11:..'mllt,"II~~~~"llJ/_
CLIENT Ms Knsten Karle PROJECT The Royal Building DATE 10-26-06
St Vincent de Paul 501 Main Street PROJECT NO 2067145
POBox 24608 Spnngfleld, Oregon REPORT NO. 4825
Eugene, Oregon 97402
B P NO COM2006-00624
DATE CAST
STRENGTH REQUIRED
STRENGTH PLACED
PRODUCT CODE
ADDITIVES
LOAD NO
CONCRETE TEMP
AIR TEMP
POUR LOCATION
DATE RECEIVED
SPECIMEN SIZE
SUPPLIER
MAX SIZE AGG
AIR CONTENT
3 TICKET NO 2553299 SLUMP 31/2"
620 F YARDAGE 100 OF 800 TIME 1035 AM
530 F WEATHER Light Rain SPECIMEN STORAGE ASTM C31
Continuous footings on line 6 from lines 0 9 to G, on 0 9 from 6 to 5 9, on 5 9 from 0 4 to 0 9, on 0 4
from 5 4 to 5 9, on 54 from 0 1 to 0 4, on 0 1 from 5 4 to 6, on 6 from 0 1 to A, on A from 3 5 to 6
Column footings at lines 04, 05, 06, E4, E5, E6, F2, F3, F4, F5, F6, C6, A4, A5, A6 Stairwell
footings on lines 2 3 from lines E 2 to E 5, on E 5 from 2 3 to 3 7, on 3 7 from 0 6 to E 5 Elevator Pit
at line E3
Continuous footing on line 6, from 0 1 to A
10-19-06
3000 pSI
3500 pSI
35-1 KV
CAST BY
R Marjama
10-20-06
6" x 12"
SACKS
CEMENT
MBI
3/4"
LOAD 3 SAMPLED
AVERAGE
TEST AGE AREA WEIGHT TOTAL COMPRESSIVE STRENGTH
DATE (DAYS) (IN 2) (LBS) LOAD (LBS) STRENGTH (PSI) (PSI)
10-26-06 7 2818 280 120500 4280
11-16-06 28
11-16-06 28
Hold
.. A - Cone B - Cone/Split C - Cone Shear o - Shear E - Columnar
REMARKS Curt (Melli) was adVised of on-site test results
TIME OF
TEST
11 07 AM
TYPE OF
FRACTURE**
o
Reviewed By
fA. ';( /1U:1L--
Michael L Meyer
Technical Manager
c Melli Construction - Curt Dawson (emailed)
Bergsund Delaney Architecture & Planning
Hohbach-Lewln Structural Engineers
City of Spnngfleld
MBI
MLMJm
ThiS report and/or enclosed test data IS the confidential property of the chent to whom It IS addressed and pertains to the speCific
process and/or matenal evaluated As such, Information contained herein shall not be reproduced In part or full and/or any part
thereof be disclosed Without FEI Testing & Inspection, Inc 's wntten authonzatlon
750 NW Come/I Avenue Corvallis, Oregon 97330 phone (541) 757-4698 fax (541) 757-2991
29540 B AIrport Road Eugene, Oregon 97402 phone (541 ) 684-3849 fax (541 ) 684-3851