Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-10-26 L~~r..t ~ ~~ ~l Geotechnical & Construcbon SeI'VlCSS Compressive Strength of Concrete (ASTM C 39) 11:..'mllt,"II~~~~"llJ/_ CLIENT Ms Knsten Karle PROJECT The Royal Building DATE 10-26-06 St Vincent de Paul 501 Main Street PROJECT NO 2067145 POBox 24608 Spnngfleld, Oregon REPORT NO. 4825 Eugene, Oregon 97402 B P NO COM2006-00624 DATE CAST STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO CONCRETE TEMP AIR TEMP POUR LOCATION DATE RECEIVED SPECIMEN SIZE SUPPLIER MAX SIZE AGG AIR CONTENT 3 TICKET NO 2553299 SLUMP 31/2" 620 F YARDAGE 100 OF 800 TIME 1035 AM 530 F WEATHER Light Rain SPECIMEN STORAGE ASTM C31 Continuous footings on line 6 from lines 0 9 to G, on 0 9 from 6 to 5 9, on 5 9 from 0 4 to 0 9, on 0 4 from 5 4 to 5 9, on 54 from 0 1 to 0 4, on 0 1 from 5 4 to 6, on 6 from 0 1 to A, on A from 3 5 to 6 Column footings at lines 04, 05, 06, E4, E5, E6, F2, F3, F4, F5, F6, C6, A4, A5, A6 Stairwell footings on lines 2 3 from lines E 2 to E 5, on E 5 from 2 3 to 3 7, on 3 7 from 0 6 to E 5 Elevator Pit at line E3 Continuous footing on line 6, from 0 1 to A 10-19-06 3000 pSI 3500 pSI 35-1 KV CAST BY R Marjama 10-20-06 6" x 12" SACKS CEMENT MBI 3/4" LOAD 3 SAMPLED AVERAGE TEST AGE AREA WEIGHT TOTAL COMPRESSIVE STRENGTH DATE (DAYS) (IN 2) (LBS) LOAD (LBS) STRENGTH (PSI) (PSI) 10-26-06 7 2818 280 120500 4280 11-16-06 28 11-16-06 28 Hold .. A - Cone B - Cone/Split C - Cone Shear o - Shear E - Columnar REMARKS Curt (Melli) was adVised of on-site test results TIME OF TEST 11 07 AM TYPE OF FRACTURE** o Reviewed By fA. ';( /1U:1L-- Michael L Meyer Technical Manager c Melli Construction - Curt Dawson (emailed) Bergsund Delaney Architecture & Planning Hohbach-Lewln Structural Engineers City of Spnngfleld MBI MLMJm ThiS report and/or enclosed test data IS the confidential property of the chent to whom It IS addressed and pertains to the speCific process and/or matenal evaluated As such, Information contained herein shall not be reproduced In part or full and/or any part thereof be disclosed Without FEI Testing & Inspection, Inc 's wntten authonzatlon 750 NW Come/I Avenue Corvallis, Oregon 97330 phone (541) 757-4698 fax (541) 757-2991 29540 B AIrport Road Eugene, Oregon 97402 phone (541 ) 684-3849 fax (541 ) 684-3851