Daily Field Report
Client.
Ms Knsten Karle
St Vincent de Paul
POBox 24608
Eugene, Oregon 97402
ProJect: The Royal Building
501 Main Street
Spnngfleld, Oregon
Date'
Project No .
Report No.:
Inspector:
ID No.'
Inspection of: Reinforced Concrete
Contractor. Melli Construction
Weather Clear
BP No.. COM2006-00624
Continuous Inspection: 0
PeriodiC Inspection: 0
Performed final Inspection on the reinforcing steel at the following locations continuous
footings on line 1, C to G, line C, from 1 to 2, line 2, from A to C, line A, from 2 to 3 5,
bottom of mat steel In elevator pit centered at lines 3E, stairwell footings along line C 9,
from 38 to 28, line D 4, from 38 to 28, line 2 8, from C 9 to D 4, column footings at
lines F1, E1, D1, C1, A 1, E2, D2, C2, A2, C3, C4, C5 and A3 Performed preliminary
Inspection on the reinforCing steel for footings around elevator pit along lines 2 3, from
E 1 to E 5, line E 5, from 2 3 to 3 6 and line 3 6, from D to E 5 ReinforCing steel was
checked for grade, Size, lap, placement and clearance ReinforCing steel was secured
with tie-Wire and supported above grade Observed the placement of 55 yards of MBI
4000 pSI (MIX 24F4NE5200) concrete In bottom of elevator pit Concrete was placed by
1 pump and was mechanrcally consolidated Cast one (1) set of four (4) 6" X 12"
concrete test cyllnpers Slump 41/4", concrete temperature 61F, air temperature 54F
Observed the placement of 500 yards of MBI 3500 pSI concrete (MIX 35-1 KV) In
footings listed above except around elevator pit Concrete was placed by pump and
was mechanrcally consolidate Cast one (1) set of four (4) 6" X 12" concrete test
cylinders from load 2 Curt (Melli Construction) was notified of on-site test results
slump 41/2", concrete temperature 59F, air temperature 56F
Items requiring correction: In elevator pit footing on line 3 6, from D 5 to E 5, rebar In
area of step IS missing bent bars and one (1) set of diagonal bars as shown on 7/S5 1
To the best of our knowledge, the work Inspected was In accordance With plans
and applicable workmanship provIsions of the I B C , except If noted above Contractor
was asked to notify our office when additional services are needed
Respectfully,
/1; -/. / Jl41r'----e __e ~
Michael L Meyef
T echnrcal Manager
c Melli Construction
Bergsund Delaney Architecture & Plannrng
Hohbach-Lewln Structural Engineers
City of Spnngfleld
MLMJw
ThiS report and/or enclosed test data IS the confidential property of the client to whom It IS addressed and pertains to the speCifiC
process and/or material evaluated As such, Information contained herein shall not be reproduced In part or full and/or any part
thereof be disclosed Without FEI Testing & Inspection, Inc 's written authOrization
750 NW Comell Avenue CoNal/IS, Oregon 97330 phone (541) 7574698 fax (541) 757-2991
29540 B Allport Road Euqene, Oreqon 97402 phone (541) 684-3849 fax (541 ) 684-3851
10-13-06
2067145
E14405
E MarJama
5235029
ICC