HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-9-20 l n~;l lriformation ~~. .10 Build On Engineering. ConsuHing · Testing DAILY FIELD REPORT Date Performed: September 20, 2006 Report Number: 722-60303-10 Client: Springfield School DIstrict #19 Project Name: A3 Academy of Arts & 1890 N 42nd Street Academics Springfield, OR 97477 Project Location: 611/615 Main Street SpringfIeld, Oregon Contractor: Melli Construction Co Building Permit No.: COM 2006-00836 Type of Inspection: Epoxy Weather: InSide Field Observations and Comments Performed continuous Inspection durrng the installation of 5/8" all thread epoxied anchor bolts In the following locations (6) at grrdllne 2 In between grrdllnes A and B, (4) on grrdllne 2 between grrdllnes Band C (15) on line 2 on the other side of the wall between grid lines A and D All anchors are for Simpson Hold Downs, HD2A, between rafters and wall Prror to Installation the predrrlled holes were cleaned uSing a nylon brush and compressed air Verrfled minimum embedment depth of 2 Inches The above listed epoxy were Installed uSing Hlltl Hit Hy 20 epoxy with ICBO # 4815 Contractor stated the nuts would be tightened after epoxy has cured The epoxy were Installed In accordance with manufacturer's direction and englneerrng approval needed In addition all anchors Installed on this date need englneerrng approval for "as bUilt" condition. There were only two Inches of embedment through the open cells of the block Plans called for a minimum of 4 inches PSI has received an RFI stating 2 Inches IS acceptable from the engineer. RFI on file To the best of our knowledge, the work above was In accordance With the bUilding department approved deSign draWings, speCifications and applicable workmanship proVISions of the International BUilding Code Inspector: Wesley Brown If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649. Respectfully Submitted, Profess'onal Service Industries, Inc. .,t~ . Tran ment Manager c. 2G Construction-Mike Kimball SpringfIeld School District # 19-John Saracono City of Springfield THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED ProfeSSional Service Industries, Inc. 1040A Shelley St . Springfield, OR 97477. Phone 541/746-9649. Fax 541/746-7163 -- l-'~ ., Information ~~. .To Build On Engineering. Consulting. 'Jesting DAILY FIELD REPORT Date Performed: September 18, 2006 Report Number: 722-60303-9 Client: Spnngfleld School Dlstnct # 19 Project Name: A3 Academy of Arts & 1890 N 42nd Street Academics Spnngfleld, OR 97477 Project Location: 611/615 Main Street Spnngfleld, Oregon Contractor: Melli Construction Co Building Permit No.: COM 2006-00836 Type of Inspection: Epoxy Weather: Clear Field Observations and Comments . Performed continuous Inspection dunng the Installation of 5/8" all thread epoxied anchor bolts In the following locations, (12) along gndllne 1 as per detail 11/S2, (3) on gndllne 1 as per detail 12/S2, (3) along gndlrne between D and C 5 as per detail 11/S2, (6) on gndlrne 3 between A and 8.5 as per detail 7R/S2, (5) anchors on gnd line 2 between B 5 and C 5 as per detail 6R/S2. These were Installed uSing Hlltl Hit Hy 20 with ICBO# 4815 with a minimum embedment depth of 6 Inches as per engineer's specificatIons Pnor to installatIon the prednlled holes were cleaned uSing a nylon brush and compressed air, Venfled minimum embedment depth of 4 Inches for dowels Inserted honzontally and venfied embedment depth of 6 Inches for dowels placed at an angle the above listed epoxy were Installed uSing Simpson Set 22 epoxy With ICC # 5279 Contractor stated the nuts would be tightened after epoxy has cured The epoxy were Installed In accordance With approved Job-Site plans and the latest reVISions dated September 14, 2006. In addition all anchors are for Simpson Strong Tie HD2A from rafter to wall To date a total of 29518 all thread anchors have been Installed To the best of our knowledge, the work Inspected above was In accordance With the bUilding department approved design drawings, specifications and applrcable workmanship proVIsions of the International BUilding Code Inspector: Wesley Brown If you have any questions regarding thiS report, please feel free to contact us at 541-746-9649 Respectfully Submitted, profess.on,CdUSfrieS, Inc. c, 2G Construction-Mike Kimball Spnngfield School Dlstnct # 19-John Saracono City of Spnngfleld THIS REPORT IS PROVIDED FOR THE INFORMA nON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED ProfeSSional Service Industnes, Inc. 1040A Shelley St . Spnngfleld, OR 97477. Phone 541/746,9649. Fax 541/746-7163 l"'~;l Info, "lOtion I:!!...... To Build On ...."....... · c.n.utansr · ~ Client: Address: Springfield School District # 19 1890 N 42nd Street Springfield, OR 97477 Placement Data Footing for shear walls along gndhne C and B COMPRESSION REPORT Project No.: 722-60303-5 Proj. Name: A3 Academy of Arts & Academics Location: 611/615 Main Street Springfield, Oregon Material Concrete Location Sampled At N/A Date Cast: 08/25/06 Ticket No' MIx No : 2617554 40-5 Date Rec'd 08/28/06 Weather: InSide DesiRn StrenRth (psi): required 4,000 Cylinder No Test Date Age (days) Field Cure Lab Cure (days) (days) 06-2603 9/1/2006 7 3 4 06-2604 9/1/2006 7 3 4 06-2605 9/22/2006 28 3 25 06-2606 9/22/2006 28 3 25 ** 1 - Cone (both ends) 2 - ConeNertlcal Cracks (one end) 3 - Columnar Remarks: c: 2G Construction-Mike Kimball Springfield School District # 19-John Saracono City of Springfield Yardage 10 10 Slump (m.)' ASTM C143 Max Aggr Size: Air Content. ASTM C231 Air Temperature (F) Matenal Temp. (F): ASTM C1064 Max Temp (F): Mm Temp (F): Specimen Size: Unit Weight (pct): ASTM C138 Time Cast. 10 50 AM Additives: Results Reported To: . SPRINGFIELD OFFICE- 1040 - A Shelley Street. Springfield, Oregon 97477 (541)746-9649 - (541)746-7163 fax September 27,2006 Date: B.P. No.: P.O. No.: Cast By: Greg Boehl and Load: Total: Supplier: Morse Bras Field Test Data 5" 1/2" 73 79 6 x 12 Curmg Conditions: ASTM C31 Compressive Strength Data ASTM C39 placed 4,000 Diameter or Cross Sect Area Cylinder WT Comp Strength F t T ., Capping Method Dimensions (s I) (Ibs) Max Load (Ibs ) (pSI) rac ure ype Test Time (Inches) C617 -03 C1231-03 603 2856 282 105,580 3,700 5 9'39 X 603 2846 283 106,385 3,740 5 9 44 AM X 597 2801 283 149,930 5,350 2 8 45 AM X 599 2821 283 156,380 5,540 3 8 42 AM X I I ~ 4 - Diagonal wIno cracking at ends 5 - Side fractures (at top of bottom) 6 - Top fractures (same as #5 but end of cylinder IS pOinted) ReS~~~IIY Submitted, P~~~~~dUSlries. Inc. Steven E Wilder Laboratory Supervisor THIS REPORT IS PROVIDED FOR THE INFORMA TlON OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL, IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES