Client. Ms Shan Yates ProJect: Pacific Cascade Date: 07/10/06
Pacific Cascade Federal Credit Union Project No.: 2057200
Federal Credit Union 1190 Mohawk Blvd Report No. E13231
1075 Oak Street Spnngfleld, Oregon Inspector: M Meyer
Eugene, Oregon 97401 ID No:
Inspection of: Ceiling Gnd Weather: Inside Continuous Inspection' L:!
Contractor' McKenzie CommercIal BPNo: COM2005-01154 Periodic Inspection 0"
06/30/06 - Performed Inspection on the drop-ceiling exposed Tee-System gnd
Installation BERC 2 clips are not Installed, additional hangar wires need to be Installed
near walls and compression struts are missing Gary Thompson (McKenzie
Commercial) was advised and was asked to notify our office when additIonal servIces
are needed
07/06/06 - Re-Inspected ceiling gnd installation BERC 2 clipS, struts and hangar wires
have been com pleted In areas greater than 144 sq ft
To the best of our knowledge, the work Inspected was In accordance with SeismiC
Installation Instruction by Armstrong World Industnes (manufacturer) attached to
approved plans and applicable workmanship prOVISions of the I B C , except If noted
above Contractor was asked to notify our office when additional services are needed
Respectfully,
(h.~~
Michael Lr Mef)r
Techntcal Manager
----
c McKenZie Commercial
Enc Hall Architects
Branch Englneenng
City of Spnngfleld
MLMJw
ThiS report and/or enclosed test data IS the confidential property of the client to whom It IS addressed and pertains to the specifiC
process and/or matenal evaluated As such, Information contained herein shall not be reproduced In part or full and/or any part
thereof be disclosed Without FEI Testing & Inspection, Inc 's wntten authonzatlon
7fJJ NN Camell Avenue CorvalliS, Oregon 97330 phone (541) 757-4698 fax (541) 757-2991
?Ql)4() R Aunnr! Rmrl FIIC"lP.I1P 0rP.cnn Q7402 nhnnA (541) 684-3849 fax (541) 684-3851