HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-10-16 Carlson Testing, Inc. MaIn Office POBox 23814 Tlgard, Oregon 97281 Phone (503) 684-3460 Fax (503) 684-0954 Salem Office 4060 Hudson Ave, NE Salem, Oregon 97301 Phone (503) 589-1252 Fax (503) 589-1309 Bend Office POBox 7918 Bend, Oregon 97708 Phone (541) 330-9155 Fax (541) 330-9163 Daily Report of Proprietary Anchors Client: BURT WALTER Project: BAYBERRY COMMONS - SPRINGFIELD Address: 2211 LAURA STREET - SPRINGFIELD, OR cn representative P, L. SANETRA OBOA 447 was on site tlus date Oct. 16, 2006 to perform SpecIal Inspection for Pemnt COM200S-0168S DFS #(s) SCOPE OF INSPECTION 1 Checked ill With supenntendent or chent representative Name' BURT Company' BURT WALTERS CONSTRUCTION 2 Inspection was "mc" GJ Contmuous D Pen odic 3 Work performed GJ In the field D At precast shop 4 If shop illspection do they have fabncatlOn and QC procedures? DYes D No GJ N/A PROPRIETARY ANCHORS 1 ReViewed prevIous mspection reports? 2 ReViewed evaluation report? 3 Venfied manufacturer's anchor use confonns to acceptance cntena m report summary Venfied followmg Items meet manufacturer's pubhshed mstallation mstructions 4 Venfied nnmmum embedment depth of the anchors, I 5 Venfied lllstallation of the anchors I 6 Venfied anchor diameter 7 Venfied steel grade 8 Venfied hole dIameter 9 Venfied type of dnll bit used 10 Venfied cleanImess of hole and anchor. 11 Venfied adheSive apphcation Yes No N/A x x x x X x x I x I I x I I x I CTI Job #: S0604278, Jurisdiction: SPRINGFIELD PO Number: Location ofpropnetary anchors mspected [to mclude gnd lmes, elevations (floors) and drawmg detalls): (6) S/8"X7" RAMSET RED HEAD ANCHORS INSTALLED AT SILL PLATES GRID LINES K/9-10, NO DETAIL OR RFI FOR WORK PERFORMED, ENGINEER'S REVIEW AND WRITTEN APPROVAL REOUIRED, REPORT SUMMARY Work mspecte1 was GJ Completed D In progress 2 Completed work mspected was not m comphance With D Approved plans and speCifications D Shop drawmgs( D RFI D DeSign change D Subnnttal [i] N/ A Document #(s) N/A Dated. x 3 Noncomphance ltem(s) were noted tlus date, detalls on followmg page(s) GJ Yes D No D N/A 4 Noncomphance Item(s) were remspected tlus date, detalls on followmg page(s) DYes D No GJ N/A D Conform D Remalll m progress Report(s) findlllgs were discussed and left With , BURT -- - --- - of 1?l.!!<-1' ~J\LT.gRS CONSTRUCTION EvaluatIon report number ESR -13 72 __ _ _ _ _ _ _____ _ Name of product bemg mstalled RAMS~':I' RID? BEAR- _ Batch Number N/A ExplfatlOn Date N / A RfC-EIVED OCT 2 4 Z006 Based on the Code, approval IS reqUIred from the BUlldmg Official before the SPECIAL INSPECTED Items noted above can be covered Carlson Testing has no authonty to direct work ofcontractor~ or subcontIactOls D See additIOnal repolt page(s) W Dlstllbute attachment" of Page Daily Report of Proprietary Anchors CTI Job #: S0604278. Project: BAYBERRY COMMONS - SPRINGFIELD For: 10/16/2006 Notes: In some cases more than one box may be checked for a gIVen Item on the front page. Our reports pertam to the matenal tested/mspected only InformatIon contamed herem IS not to be reproduced, except m full, wIthout pnor authonzatIon from thIS office. If there are any further questIons regardmg tills matter, please do not hesItate to contact thIS office. Respectfully submItted, CARLSON TESTING, INC ~~~ Manager PLS/LS CC': CITY OF SPRINGFIELD DIAMOND ENGINEERING TONY KOACH ARCHITECT Oct 17, 2006 S0604278. Carlson Testing, Inc. Incompleted Items List (NCL) PrOject Name Project Address Penmt No PO No BAYBERRY COMMONS - SPRINGFIELD 2211 LAURA STREET - SPRINGFIELD, OR COM2005-01685 Item # Insp, Date Item Description Compliance CTI Sign-Off Date Corrected 1 JR 06/23/2006 MIX DESIGN 2144 NOT APPROVED 2 JR 07/19/2006 MIX DESIGN #4184 NOT APPROVED 3 GK 08/16/2006 INSTALLATION OF SEISMIC ANCHORS, (4) HOLES NEED TO BE RE-DRILLED TO PROPER EMBEDMENT DEPTH (2) EAST WING & (2) SOUTH WING 4 GK 09/27/2006 NO ICC REPORTS ON SITE FOR RE500 & HY-150 5 GK 09/27/2006 NEED ENGINEER'S WRITTEN APPROVAL FOR ANCHOR TYPE & EMBEDMENT DEPTH, NO DETAILS AVAILABLE FOR ANCHORS INSTALLED FOR INTERIOR WALL SILL PLATES SEE DAILY FIELED REPORT 6 PLS 10/16/2006 NO DETAIL OR RFI FOR INSTALLATION OR..RAMSET RED HEAD WEDGE ANCHORS FOR SILL PLATES GRID LINES K/9-10, ENGINEER'S REVIEW AND WRITTEN APPROVAL REQUIRED CC BURT WALTER CITY OF SPRINGFIELD DIAMOND ENGINEERING TONY KOACH ARCHITECT PrOject Manager. S. DUGGER Page' 1