HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-6-23 Carlson Testing, Inc. Constl uctlOll lnspectloll.!> & Related Tests Geotechmcal Consultmg Mam Office POBox 23814 Tlgard, Oregon 97281 Phone (503) 684-3460 Fax (503) 684-0954 REPORT OF 6 X 12 CONCRETE TEST SPECIMENS 1 Test Methods: ASTM C31/C172/C192/C617/C1064/C231/C143 Date Molded: 06/23/2006 Permit #: COM2005-01685 Client: BURT WALTER Project: BAYBERRY COMMONS - SPRINGFIELD Address: 2211 LAURA STREET - SPRINGFIELD, OR Contractor: X Subcontractor: Concrete Supplier: EUGENE SAND & GRAVEL INC Truck #: 264 Load #: 1 Weather: SUNNY Test Time: 11 . 15 AM Cylinders were cast for the following locations: ELAVATION PIT @10.5/11.5 @ K/ K.2 9SLAB ON GRADE) Salem Office 4060 Hudson Ave, NE Salem, Oregon 97301 Phone (503) 589-1252 Fax (503) 589-1309 Bend Office POBox 7918 Bend, Oregon 97708 Phone (541) 330-9155 Fax (541) 330-9163 Job Number: S0604278. Jurisdiction: SPRINGFIELD Cast By: J. REID Ticket#: 300523 Air Temp. at Sampling Time: 83 Total Concrete Placement Location: ELEVATION PIT (SLAB ON GRADE) 10.5/11 5 @ K/K.2, 36" X 36" X 14" FOOTINGS @ B1 @ J, N @ 14 AND I.1 @ 11 Strength Requirement: 3000 psi r c @ 2 8 Mix Number: 2144 Cone. Temp: 74 Admix/Amt: NO BATCH INFORMATION Register Number: 0002108 Days Slump: Cement Type: Lab Location: SALEM Set Test @ Date Test Total No. Days Rec'd Date Load I 7 06/23/2006 06/30/2006 97325 / 28 06/23/2006 07/21/2006 28 06/23/2006 I 07/21/2006 I I I I I I I I I I I' 2.500" % Air: 1. 50% Max Agg: .75 Cubic Yards: 4.5 Area Unit PSI Tested By JDV Type Of Fracture 28.05 3470 3 Please see reverse side for additional information. Job Number: S0604278. Register Number: 0002108 Project: BAYBERRY COMMONS - SPRINGFIELD Date Molded: 06/23/2006 ----- A~ \ < I m [25 nun] x , Type I Reasonable well-formed cones on both ends, less than I m [25 nun] of crackmg through caps Type 2 Well-Formed cone on one end, vertical cracks runnmg through caps, no well-defined cone on other end Type 3 Columnar vertical crackmg through both ends, no well-formed cones \ / 1\ / Type 4 Diagonal fracture with no crackmg through ends, tap with hammer to dlstmgUlsh from Type I Type 5 Side fractures at top or bottom (occur commonly with unbonded caps) Type 6 SImIlar to Type 5 but end of cylInder IS pomted Astensked (*) umt PSI test results dId not meet lIsted acceptance cntena Remarks: The area of the cylmders IS based on an assumed value of 28 26 unless noted cc: CITY OF SPRINGFIELD DIAMOND ENGINEERING TONY KOACH ARCHITECT Project Manager: S DUGGER Reviewed By: .~ [') Ste~ Our report pertams to the matenal tested only The mformatlOn contamed m thIS report IS proVIded subject to all terms and condItIons of CTI's General CondItIons m effect at the tIme thIS report IS prepared No party other than those to whom cn has dIstnbuted thIS report shall be entItled to use or rely upon the mformatlOn contamed m thIS document.