Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-6-30 (5) Carlson Testing, Inc. REPORT OF 6 X 12 CONCRETE Main Office POBox 23814 Tlgard, Oregon 97281 Phone (503) 684-3460 Fax (503) 684-0954 TEST SPECIMENS Test Methods: ASTM C31/C172/C192/C617/C1064/C231/C143 Date Molded: 06/30/2006 Permit#: COM2005-01685 Client: BURT WALTER Project: BAYBERRY COMMONS - SPRINGFIELD Address: 2211 LAURA STREET - SPRINGFIELD, OR Contractor: x Snbcontractor: Concrete Supplier: EUGENE SAND & GRAVEL INC Truck #: 260 Load #: 31 Weather: SUNNY Test Time: Cylinders were cast for the following locations: SLAB ON GRADE 12 @ L Total Concrete Placement Location: 1-31 @ A-W Strength Requirement: Mix Number: 2144 Admix/Amt: P8G - 240 OZ Register Number: 0002134 3000 psi r c @ 28 Cone. Temp: 78 ConstructIOn InspectIOns & Related Tests Geotechnical Consulting Salem Office 4060 Hudson Ave, NE Salem, Oregon 97301 Phone (503) 589-1252 Fax (503) 589-1309 Bend Office POBox 7918 Bend, Oregon 97708 Phone (541) 330-9] 55 Fax (541) 330-9163 Job Number: S0604278. Jurisdiction: SPRINGFIELD Cast By: 11:42 AM Days Slump: Cement Type: I Lab Location: SALEM C. BIDWELL Ticket#: 301102 Air Temp. at Sampling Time: 79 4.000" % Air: .75 1. 40% Max Agg: . Cubic Yards: Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By 4 7 07/03/2006 07/07/2006 79520 27.69 2870 5 JDV 28 07/03/2006 28 07/03/2006 Please see reverse side for additional information. Job Number: S0604278. Register Number: 0002134 Project: BAYBERRY COMMONS - SPRINGFIELD Date Molded: 06/30/2006 --- ~ < I In [25 mm] XA AY{ t , ':\ Type I Reasonable well-fonned cones on both ends, less than I In [25 mm] of cracking through caps Type 2 Well-Fonned cone on one end, vertical cracks runnmg through caps, no well-defined cone on other end Type 3 Columnar vertical cracking through both ends, no well-fonned cones \ / 1\ / Type 4 Diagonal fracture with no cracking through ends, tap with hammer to dlstmgmsh from Type I Type 5 Side fractures at top or bottom (occur commonly with unbonded caps) Type 6 SimIlar to Type 5 but end of cylinder IS pomted Astensked (*) umt PSI test results dId not meet lIsted acceptance cntena Remarks: The area of the cylmders IS based on an assumed value of 28 26 unless noted cc: CITY OF SPRINGFIELD DIAMOND ENGINEERING TONY KOACH ARCHITECT Project Manager: S DUGGER Reviewed By: ~ /I _ __ _ _ __ __ __ Ste.:.r~ Our report pertams to the matenal tested only. The mformatIon contamed m thIS report IS provIded subject to all terms and condItIons of CTI's General CondItIons m effect at the tIme thIS report IS prepared No party other than those to whom cn has dlstnbuted thIS report shall be entItled to use or rely upon the mformatIon contamed m thIS document