Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-7-7 Carlson Testing, Inc. REPORT OF 6 x 12 CONCRETE Test Methods: ASTM C31/C172/C192/C617/C143 Date Molded: 07/07/2006 Permit #: COM2005-01685 Client: BURT WALTER Project:BAYBERRY COMMONS - SPRINGFIELD \ Address: 2211 LAURA STREET - SPRINGFIELD, OR Contractor: x Subcontractor: Concrete Supplier: EUGENE SAND & GRAVEL INC Truck #: 271 Load #: 1 Weather: MaIn Office PO Box23814 Tlgard, Oregon 97281 Phone (503) 684-3460 Fax (503) 684-0954 TEST SPECIMENS ConstructIOn InspectIOns & Related Tests Geotechnzcal Consulting Salem Office 4060 Hudson Ave, NE Salem, Oregon 9730 I Phone (503) 589-1252 Fax (503) 589-1309 Bend Office POBox 7918 Bend, Oregon 97708 Phone (541) 330-9155 Fax (541) 330-9163 Job Number: S0604278 Jurisdiction: SPRINGFIELD Cast By: Test Time: 2 : 35 PM Cylinders were c;1st for the following locations: Total Concrete Placement Location: ENTRY WAY COLUMN FOOTINGS Strength Requirement: Mix Number: 2144 3000 psi rc @ 28 Days Slump: Conc. Temp: N/T Cement Type: I Admix! Amt: Register Number: 0002164 Lab Location: SALEM Test @ Date Test Total Days Rec'd Date Load 7 07/10/2006 07/14/2006 74330 28 07/10/2006 08/04/2006 28 07/10/2006 I 08/04/2006 I Set No. Area 27.69 I I I I I J T. VANN Ticket#: 301587 Air Temp. at Sampling Time: 80 4 . 000 " % Air: N/T Max Agg: 3/4 " . Cubic Yards: Unit Type Of Tested PSI Fracture By 2680 3 JDV I I I I I I I I I I I L -EEL" ' r\ r:. vc.. JUL 2 5 7nnfi Please see reverse side for additional information. Job Number: S0604278. Register Number: 0002164 Project: BAYBERRY COMMONS - SPRINGFIELD Date Molded: 07/07/2006 ~ A9{ \ < I In [25 mm] x '\ Type I Reasonable well-fanned cones on both ends, less than I In [25 mm] of cracking through caps Type 2 Well-Formed cone on one end, vertIcal cracks running through caps, no well-defined cone on other end Type 3 Columnar vertIcal cracking through both ends, no well-fanned cones \ / 1\ /' Type 4 DIagonal fracture wIth no cracking through ends, tap wIth hammer to dIstingUIsh from Type I Type 5 SIde fractures at top or bottom (occur commonly wIth un bonded caps) Type 6 SImIlar to Type 5 but end of cyhnder IS pOinted Astensked (*) umt PSI test results dId not meet lIsted acceptance cntena Remarks: The area of the cylmders IS based on an assumed value of 28.26 unless noted. cc: CITY OF SPRINGFIELD DIAMOND ENGINEERING TONY KOACH ARCHITECT Project Manager: S DUGGER Reviewed By: ~ -'^' --- -- Steve~~ Our report pertams to the matenal tested only The mformatIOn con tamed m thIS report IS provIded subject to all terms and condItIOns of CTl's General CondItIons m effect at the tIme thIS report IS prepared No party other than those to whom cn has dIstnbuted thIS report shall be entItled to use or rely upon the mformatIOn contamed m thIS document.