Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-6-30 Carlson Testing, Inc. Constructzon Inspections & Related Tests Geotechmcal Consultmg MaIn Office PO Box 23814 Tlgard, Oregon 97281 Phone (503) 684-3460 Fax (503) 684-0954 Salem Office 4060 Hudson Ave, NE Salem, Oregon 97301 Phone (503) 589-1252 Fax (503) 589-1309 Bend Office POBox 7918 Bend, Oregon 97708 Phone (541) 330-9155 Fax (541) 330-9163 REPORT OF 6 X 12 CONCRETE TEST SPECIMENS Test Methods: ASTM C31/C172/C192/C617/C1064/C231/C143 Date Molded: 06/30/2006 Permit #: COM2005 -01685 Client: BURT WALTER Project: BAYBERRY COMMONS - SPRINGFIELD Address: 2211 LAURA STREET - SPRINGFIELD, OR Contractor: X Subcontractor: Concrete Supplier: EUGENE SAND & GRAVEL INC Truck #: 262 Load #: 3 Job Number: S0604278 Jurisdiction: SPRINGFIELD Cast By: c. BIDWELL Weather: SUNNY Test Time: 6:30 AM Ticket#: 301034 Air Temp. at Sampling Time: 66 Cylinders were cast for the following locations: 22 @ K.5 FOOTINGS Total Concrete Placement Location: 1-31 @ A-W Strength Requirement: Mix Number: 2144 3000 psi fc @ 28 Days Slump: Cone. Temp: 73 Cement Type: I 4.250" % Air: 1.00% Admix/Amt: P80 - 240 OZ Register Number: 0002131 Max Agg: .75 Cubic Yards: 30 Lab Location: SALEM Set Test @ Date Test Total Area Unit Type Of Tested No. Days Rec'd Date Load PSI Fracture By 1 7 07/03/2006 07/07/2006 83290 27.69 3010 3 JDV 28 07/03/2006 07/28/2006 28 07/03/2006 I 07/28/2006 I I I I I I I I / I I Please see reverse side for additional information. Job Number: S0604278 Register Number: 0002131 Project: BAYBERRY COMMONS - SPRINGFIELD Date Molded: 06/30/2006 -.j x AW \ ' < I m [25 mm] '\ Type I Reasonable well-formed cones on both ends, less than I m [25 mm] of crackmg through caps Type 2 Well-Formed cone on one end, vertical cracks runmng through caps, no well-defined cone on other end Type 3 Columnar vertical crackmg through both ends, no well-formed cones \ / -- 1\ / Type 4 DIagonal fracture wIth no crackmg through ends, tap with hammer to dlstmgUlsh from Type I Type 5 SIde fractures at top or bottom (occur commonly with unbonded caps) Type 6 SimIlar to Type 5 but end of cylmder IS pomted Astensked (*) umt PSI test results dtd not meet hsted acceptance cntena Remarks: The area of the cyhnders IS based on an assumed value of28.26 unless noted cc: CITY OF SPRINGFIELD DIAMOND ENGINEERING TONY KOACH ARCHITECT Project Manager: S DUGGER Reviewed By: ~~u((,L-, Steven IIllger Our report pertaIns to the matenal tested only The InfOrmatIOn contaIned In thIS report IS provIded subject to all terms and ~condItIons of CTI's General CondItIons m effect at the tIme thIS report IS prepared No party other than those to whom cn has dIstnbuted thIS report shall be entItled to use or rely upon the mformatIOn contamed In thIS document.