Report of Inspection Services
Weldin~/High-Strength Boltin~
Client Ms Kristen Karle
St Vincent de Paul
POBox 24608
Eugene, Oregon 97402
Project:
St Vincent de Paul
Retail/Warehouse Facility
4555 East Main St
Spnngfleld, Oregon
Date'
Project No.'
Report No .
Inspector
ID No..
Inspection of. High Strength Bolts
Fabncator or Erector: NW Steel Structures
Contractor. Melli Construction
Shop: 0
Weather:
BP No.:
08/25/06
2067065
E13969
M Postler
5232606-85
ICC
Field: 0
Clear
COM2005-01772
Performed tension venflcatlon on the 1 1/8" A325 high strength bolts uSing turn-of-the-nut method Three
bolts were Installed to a snug-tight condition In a Skidmore-Wilhelm tension Indicator, marked and turned
an additional 1/3 turn To the best of our knowledge, the bolts tested Will meet and/or exceed the
minimum tension requirement of 56 kips per A I S C manual
While on-site, verified the bolts at each beam to column are In snug-tight condition and were marked for
the additional 1/3 turn
Contractor was asked to notify our office when additional services are needed
Respectfully,
~h~
Dale A Webber
Structural Steel Supervisor
c Melli Construction
Branch Englneenng
City of Spnngfleld
DAWJw
RECEIVED
SEP 0 5 2006
This report and/or enclosed test data IS the confidential property of the client to whom It IS addressed and pertains to the specific
process and/or matenal evaluated As such, Information contained herein shall not be reproduced In part or full and/or any part
thereof be disclosed without FEI Testing & Inspection, Inc 's wntten authonzatlon
750 NW Comell Avenue Corvallis, Oregon 97330 phone (541) 757-4698 fax (541) 757-2991
29540 B Airport Road Eugene, Oregon 97402 phone (541) 684-3849 fax (541) 684-3851
63050 Corporate Place, SUite 2 Bend, Oregon 97701 phone (541) 382-4844 fax (541) 382-4846