DAILY FIELD REPORT
Date Performed: September 25, 2006 Report Number: 722-60145-48
Chent: Mr John Helander Project Name: Regional Sports Center, Ph 2
Essex General Construction Basketball BUilding
4284 West 7th Avenue Project Location: 200 South 32nd Street
Eugene, OR 97401 Spnngfleld, Oregon
Contractor: Essex General Construction
P.O. No.: Permit No.: COM2005-01773
Type of Inspection: High Strength Bolts Weather: Clear
Field Observations and Comments
'Arrived on-site to perform special inspection of 3/4" diameter A325 high strength bolts In the primary structural roof
connections Bolts Inspected were establIshed as "snug tIght" prior to the final 1/3 turn whIch was performed thIs date at
the follOWing gnd line locations 2-9/B 2-B 8 To the best of our knowledge, the work Inspected above was In
accordance with the bUilding department approved deSign draWings, specifications and applicable workmanship
provIsions of the International BUlldrng Code The contractor was asked to notIfy our office when additional services are
needed
Inspector. Chris Thomason, ICC # 5069949-85
If you have any questions regarding this report, please feel free to contact us at 541-746-9649
Respectfully Submitted,
Professional Service Industries, Inc.
~
Christopher Thomason
Structural Steel Field Supervisor
C City of Spnngfleld
Solarc Architecture - Galen Ohmart
Roy Gray
Branch Engineering - Rene Fabricant
THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED
Professional Service Industrres, Inc. 1040A Shelley St. . Sprrngfleld, OR 97477. Phone 541n46.9649. Fax 541n46-7163