Loading...
HomeMy WebLinkAboutPermit Building 1990-8-13 ~ / --- f~" RESIDWTlAl" .' "0../ APPLICAT./PERMIT 225 North 5th Street SpringfieZd, Oregon 97477 BuiZding Division 726-3753 Job Location: 43 y q G.f d {'i/ hPfaf AsceBoorc Map N I (j ()()?:,Q ~4 U Subdivision: DCi/1 ~('cJ ,"dft"' ~ To: Lot N Q ,?Cf t)7! '~.:-- :. " ~. ~ ., " o.mer: Cf\II!~' r J.,))YJ I)) I!:ill:.Mi r S --"CIA,/> G re.eh Acidms: 2ft fP I VQ/lVUI SI- Phone: -sf ~ 2,s2' 10 Cit>J: gk~~ Zip: 17Qt/g":--7 @NmJ n Addi ticn ri Remodel. n .'~obi 1.a 110m.:! Describe 11'0]'>1(: " SF{2..es ~ Data of Applioation / - 2fn -q'O Contractors General C()~A r-h'>~'/l , Plumbing i r'lechanical . I E~"ccri.!;a 1 I StlPe~"efi;;".~JLElectr~ci.:1n Value S4, L/LJ'd. ~, Recei.vt .'1 IXnQ,-::<" AdrlreR~ LiRe. Y \).f1l1 ,AI\ ) ,.. "'-. m..f, Bldrs Board LI (a 2.01 . , \ ~ ...... \. . . ... Sigr.cd: Data: &fU:nJ k'l/j,.Cf() "' ' l Re~. ~";;(~L/jll PhoOf' ~I./.~.~~' I " I I i ~ - , It is tho responoibiZi.ty of the permit holder to Bee that all. inopectio71S are made at :~hB propel" tim~J that (Jach .::ddrOBB is readab!B from the street. and that the permit card is lacated at the front of the property. .t!Jui!.ding Diui:io!': apprDt.'ed plan shall remain on t1w Building Sit:; at all times. Pt?OCSDURE Fon rN,~pF;r;rrON R~OUEST:CALL 726-3769 (l'ccorder) state your City designated .job__ nwr.ber~ job addrc8S~, typo of in:Jpec:ictl rcquested ar:d when you lJill be ready for inspcction~ Contractors or ctme:'s name and ph07ie~numbcl'. Requests received befcre 7:00 a-:'l :.,'ill be made the same dcy~ requests made after 7:00 am uill ba made the next :.JOrkinJ day. R~~Ji~p~ rnFrp~tin~R D SITe INSPEC':'ION: To be rrr:zde after excavation, but prior to set up of forms. D . UNDEHSLAB PLUMBING. ELECTHICAL & MECHANICAL: To be made before any work is ~ovcred. K7l FOOTING ~ FOUND,1TION: To be llXlde ~ after trenchcs are excavated and forms are el'ected~ but pl'ior to poul'ing ccnCreto. ~ UND~RG,~~.~.'D PLUM3INGJ~~~R)~ W L[R1.~..",!v~. J To be roode p1'1.01' tlrrn,- ~nahee. 12l lZf UIlDE,~FWOIfPW/.!EJII/fi>& MECHANICAL: To be ma4.a prl,or to instaz.Latl,on of floor insulation 01' decking. POST AND BEAM: To be made prior to installation of floor insulation 01' decking. ROH t'LUHBINEf,ECTRTCAL--yi!EClI- ANICAL 0 war. l,S to DC cov~ .ur.~thcse inspections have beer- 'made \ and approve~. FIREPLACE:. PriOI' to placir.g facing matel'ials a'nd before froming inspec- tior:. FRA!~TlIf;: Nust be l'equeoted aftel' approvaZ of rough pZumbing, a~ectri- cal t mechanical. AU roofing bracing t chimneys, et". nr..lst be ,completed. !lo ~l'k is to be CGn- : cealed until thia inspection has . b6~n made and approved. ~ o Your City DeDigr.ated Job Nwnber 10: 1'\71 INSULATIONIVAP08 BAHHIEH INSPECTION: ~ To be rrrlde aftel' aU insul..::.tion w.d '. rcquired LlapOI' ba1'l'iers are in place .. ;:.;! but b-efore any "lath, gypswn board or lonll. covering is applied~ and bafor'e any inoulation is concealed. '0 DHYWALL IIISPECT!ON: Tc be made aftel' aU drywaU is in place, but prior to any taping. O MASONRY: SteeZ Zocation~ bo~d beamo, grouting or verticals in accordance uith U.B.C. Section 2415. O WOODSTOVE: After installation is ccmpleted. ~ CURB & APPROACH AP.WN: Afte:- forms'. ~ are erected but prior to pounng - \ .::onarete. \ 1)(1 ~IDE'WACK & DRIt'EfIAY: Fol' all con~ \' ~ crete paving within stl'ect right- of-way, to bc,made aftel' all exca- Llating complete & foI'm work & suba . base material in. place. O !'ENCE: . Wher: compZote -- Provide gates or movable sections through P.U.E. Gn- WO aree-t--f-rea.S J C(;'71Clh7 .;--' 1./- DEUOLIT10!/ OR ;~:OVE!J BfJILDIj/CS :J Sani~y .seuer ~~ppe~ ~f ~~oPC,~~Y lfro, , . I ,. .,I"~ ,',~ hll W ,AI""\,I ',ll l~. J.L .1,\ ~ Septia tank ~.u:rp.-;d and fiZZe~ uith g1'a:Jcl -, Final - rthen above itc:~s are ccmpletcd ~ and when demolitior: is completo or Bt~~- ture mDLlec crn.:I premises cleaned up. Mobile Hcmes =:J Blocking and Set-~p =:J Plumbing c~nnection8 a_ seuer and wa:Qr ---1 Electrical Connection - Blocking, BotaUP ~ and plumbing connections nr..lst 1;e appl'::n.:ed beforc requesting el.ec:rical inspoc:ion ~ Accessol"d Buildl,ng ] Fina l - After p"rc1:es, etc. are compl8t~d. skirting, dacks, o . , '- All 'p'oJ'act conditions, auc.&: as OIC 1..,nstaLlation of street troes, "co.o;rplotion of the l'equil"ed landscc:pir:g, etc., must be satiofied before tho BUICDINe 'FINAL can be r:zqueotsd. ~ FItJAl. PLUMBll/G lZl FIliAL UE~HA.'IICAL ,~ FINAL ELECTHICAL ~CJ o FINAL BUILDING: The Final Building Inspection must bo l'oqueoted aftel' the Final Plumbin~ Electrical, and Mechar.ical Inspectiono have been made and appl'ov2d. .' . '.' " l "'AU. J.lANHOLES AND CLEIlNOUTS Nll.t;T BE /lCCESSIBLF., A~J~s;r!f.r::NT\TO, BE fJ.~{JE A.T NO CaST TO CI'I'Y Pare of 2 -~- .. -- I JOB NO. C({JYi.liv SOLAR ACCESS i Zona: ' ~ Oaouoano" G. Lot Sq. Ftr;. % .:Jf lot C.:JVeragc: ., of Stories Total Height_ Topography I ITEN I Main SQ.FTG 1./57... .t22:YJ Gcraqe -f~o/r:;o r;r:rt:!f}Y'f. ACCeS80rl/ ~ 4-~ TOTAL VALUE Is.D.c. (vaLue) 1.5 "'. Building Permi t sea to Sw-charge Total Cha.;>gea WT TYPE Interior COI'ner Panhandle CUL-de-sac .-;:J- - ."111 REQ.- L-COG~ I [,at Faces - I I P.L. INOI'th lEast ISouth I"est Type/COt:Bt: . I I F:n2I'nll SouI'Ce8 I I Heat Access. I I Water Hf?otf?r e./~c.. UY-la..P I I Ra>>qe 17 I I FiI'eplace I~ I I Wood:;;tove. II ~ Bedrooms: T.,oo Setlyu!~8 House CaI'aqe -- Faes ~':ldJv;~~!.(d)157gf.flBuilding Value & Permit ' {il '''D ......-(~. 'f/Q,This pennit is granted on the erpreaB condition that the said constI'Uction .~ ~~shall, in all respects, conform to the Ordinance adopted by the City of Springfield, including the Zoning ordinance, regulating the construction and UGe of buildings, and m~y be suapended or I'evoked at ar.y time upon vic- lation of any provisions of said Ordinances. 1-, ,.., /1 2..0 .. l7j!.)___"'::~ slf2~~ I f?Xfn.1t , 21'~t:').:> /4 )'0 3/ 2,'~O I, I I ( ~ c; --; So I) 2-0 ()O I /500 I 20~0 I 122 5'0 I c.. I} I 1/2.a ~ II ' . FEE lITEM I Futures I nesidential (J bath) I Sarli tary Sewer I Water ~ sav6<. Plumbing Permit Stats Suzocr.arge Total Charaes 1"0. 1:3; I I I CHARGE FEE I ITEM Hes. So. fta. <~oqo I Haw/Extend Circuits I Temporary Service I Ele~trical Permit Sta.te Surcharae Total Charqes I IrSM I Furnace ETU' S I E=haust llood I Vent Fan I W:>ods to;,Je Permit Issuanca Mechanic::zl Permit State Surcharai: Total CharaeD -- E/lCHOACHMEIIT -- I Sec-.,(rit~ D2lXJ3it I Storaqe I Main tenance Permit Total Charoes Curbcu: I Side>o>alk Pence Electrical ~b~l Mobile lIome I rOTIIL AMOUNT DUF::. I ~"1 .'~ () I , I' Where State LaLJ requires tr.at the electrical work be done by an ElectI'ical ContractoI', the electrical portion of this permit shall not be valid until I c:;.()() I the label has befn s':.,ne'fJli( the Eleot1'ical.Co, t1'ao~i~ I I ~D:.NJ '1-0 ~O ) \~o~~i.eD~Mci) ~y I ...-:: ""1<::::..1- IC')-:..:::b..2J A NO. CHARGE '" I I NO. FEE CHARGE I J'5 40 7!> /5.7$ /3.'10 /5.<?V I I .) 3.A.tc/J IPlan Check Fea: 2-;;;2,70 Icate Pai.d: 7-7,Jp.'QO !Heodpt Hi-, f7'if"5t:; ISig"ed: (~ Plumbing Pe r m it No pereon Dhall construct, instal?, aZter or change any ne/J cr e:::isting plumbing or drainage syst~ in ~hole or in part, unless such person is the legal possessor of a valid plumber's license, except that a person may do plwnbing tJOrk to property /Jhich is owned, leased or operated by the appli- cant. ' Electrica I Permit Mechanical Permit .1 .' , - - ~ " ~m~ ,-~. . 1latf/icl/J I HAVE CAREFULLY EXAMINED the completed application foI' permit, and do I hereby ceI'tify that all i~fo~tion hereon is tI'ue and correct, and I fuI'ther ceI'tify that an.y ar.d all IJOrk perfor:ned shatz b6 do:-ze in accor- I dance with the Ordinances of the City of Sprin.(Jfictd, and tll~ La'.,;s of tho ~ A State of Oreg.:m p~rtain.ing to the work describcd hero:.n, and :hat NO OCC!)- FANCY will be made of any struatura without p3~is3ion of the Building Oi- I vision. I furthor certify th::1.t o~ly cont1"actoro ar.d e:nplDY,oes wi:o are in I co~pliance with ens 701.05~ ,/Jilt be used.on. this project I I I I I I , D.ltr.