HomeMy WebLinkAboutPermit Plumbing 1985-9-26 ~I .. RESlottHIAL" APPLICATION/PERMIT 225 North 5th Street SpringfieZd, Oregon 97477 BuiZding Division 726-3753 (\1"n;t ..;=. .' Elderberry, Springfield, Oregon , Job Location: 4362 ABaSBOOl'S Map H Subdivision: QJner: Chuck Peterson 4362 Elderberry ~Q~ Springfield, Oregon Address: City: G.", !Xl Addition n Remodel n .'.fobi to Homo 0/-2t -;(5" 9/402. 44887 Date of Application (:ontract01'8 97478 Tcz Lot # Phone: 746-7988 97478 Zip: Describe fl'Ol'k: Install domestic solar hot water system V~luer;; OV 0 ,~ Address, Ave, ,Eugene ./ Lise. II ~eral SUNDANCE' SOLAR 4093 West 11th Plumbing Electrical Uechar.ical CO"8t~Ction Lender . .1:11\01\ . ., .~" . ..CC6-:.pt . (,l, 1/7,;;:;'5 CoV ;Ve.~0: Va.lM.,-e m.x:/,a>r , /1~iJ- . t . . ([) /G Signed: Data: cr::- q- 01-0 ~ 6~ Eroil'C8 4/03!i986 Phone 344-1594 It is the responoibiZity of ths permit holder to 8S8 that aU inspections aPe made at '!:hB proper tUne, that each .:dd:r888 is l"eadah~e froom ths street, and that the permit ca:rd is tocated at the fron.t of the property. -Bu.itding Dividor: approved Pl.a1:I shaU remain on th2. BuiZding Sit:> at all times. PROCEDURE FOR INSPECTION RE:Q(fE'5'?::CAll 726-3769 (recorder) state your City designated job number" job adircss" type of in3pec-;ic11 requested ar.d .when you win be peady fol' ir.spcction". .CO'1tr>actcl's or Ot.me::"D. 1U:.'7:e and ;;hone_ nu.~.hCl". .Requ&3tD rGc()1.vlld befcro 7:00 a':"l :..'iH be made th~ same day" requests made afta' 7:00 am r.rizt be nr:uie the ~t :.JOrki11G day. Y~r City Desigr.ated Job Number Is: g 5" () Reaui~ed InsvecticnR D. SITE INSPECTION: To be nr:zde after excavation" but prior to set up of . forms. O : UNDERSLAB PLUI.fBING. ELECTRICAL & . MECHANICAL: To b6 made beforB any . lUOrk is covered. o FOOTING & FOUNDATION: To b. ""de after trenches are excavated and forms are erected" but prior to pouring ccncrete. UNDERGROUND PLUMBING, SEWER, W.4TEFf" DRAINAGE: To be rrade pI"ior to fi"L- .'Lir.g trenches. 0, UNDERFWOR PLUMBING & MECHANICAL: . 'To be made prior to insta Z lation of floor insulation 01' decking. O POST AND BEAM: To be made prior to instalz.aticn of floor insulation or . deoki"!;. O ROUGH PLUMBING. ELECTRICAL & MECR- . ANICAL: No work is to be cOL'ered ,untiL these inspections have been made and approved. . O FIRF:PLACE: Prior to pl.ccir.g faoing materiaLs and before framing inspec- tion. o D! FRA~~ING: MUst be requested after approvaL of rough pLwr.bing" electri- .cal & mechanical. AU roofing bracing d chimneys" etc. nr..tst be :' completed. No lJOrk is to be con- ,,..;..cealed untU thin inspection has .:' be~? made and approved. U INSULATION/VAPOR BARRIER IIlSPECTIOIl: To be made after all insulation ar.d : - . - required vapor barriers are in place ,: .' but before any lath" gypsum board or uxzU covering is appl.ied" and beforB " - -.~y insulation is concealed. O DRYWALL INSPECTION: To be made after aU drywaU is in place" . but prior to any taping. O. MASONRY: Steel location" bo1uI beama" grouting or verticals in accordance with U.B.C. Section 2415. D WOODSTOVE.: After installation is completed. D CURB & APPROACH APTfON: After forms are erected but prior to pouring co~rete. SIDEWALK & DRIVEWAY: For all. con- crete paving lJithin street right- of-lJaY" to be made after an exca- vating complete & form work & sub- base material in place. 13/ I DEUOLITION OR ;~:OVED BUILDIilGS :=J Sani -;ary S8"...161' capped ~t r>>:.opt:.rt-:i lir:e ~ Septic tank p".A.'i:ped and fine~ with gra.~el --, Final - rrhen ahcve ite.'7Is are ccmplBted ~ and when demolition is complete 01' stru~- ture moved and premises :: leaned up. I Mobile Hemes ::J Blocking and Set-up ::J Plumbing connections -- SC1J6I' and lJatBr ::J Electrical Conr.ection - Slocking" SBt-up and plumbing connections nr~st be approvBd . before requesting electrical inspectio~ ::J Accessory Building ] Fin..:zl - Aftor p~rc1:e8" skirting, decks" etc. are camplett:.d. o FINAL PLUMBING All project conditions" such as the instaLlation of stpeet trees, ca~lotion of the required landsccpir.g" etc." must be satisfied bcfope the BUILDING FINAL can be P3questad. o ':::J ::::J :::J FINAL MECHANICAL o FINAL BUILDING: The Final Building Inspection must be requeoted after the Final Plumbing Electrical, and Mechar.i,caL Inspections ha.V(3 been made and approved. FINAL ELECTRICAL , .' . \ \." \ D o PENCE: When COI71pl6te -- Provide. gates or movable sections through P.U,E. , . .-tALL MANHOLES AND CLEANOUTS. HUST BE ACCESSIBf.E" ADJUST!/EllT TO BE !.HDE I1T /.'0 CDST TO CITY Page! of 2 ~~. . o \~ 1 : I JOB NO. i5D f!31 I Zona: Lot Sq. F,t{;. S of "lot Coverage !I of Stories Total Height Topography I lITEM I Main I GcPaae I Carport I ACCe8801'U SQ.FTG TOTA& VAWE Is.D.c. {vat.uc} 1.5 :r: Building Permit State Surcharge TotaL Charges I ITEM NO. I Futures I ResidentiaL (1 bath) I Sanitary Sewer> I Water Pl.;qn.bing Permi t State Surcr.arge Tota 1. Charaes lITEM I Res. Sa. fta. I Naw/Extend Cirocui ts I Temporary Service I EZeatrical Permit State Surcharqe Total Charqes IIT!::M I Furnace ETU' S I Exhaust Hood I NO. I I I I I ( Permit Issuance Vent Fan J100dStO:J8 Mechanical Permi t State Surcharae 7'ot;al ChaT'ORff -- ENCROACHMENT -- ISe~~~ Davosit Storage Maintenance I Pcrnrit I Total. Chat'aCB I Curbcut I SidewaLk IFe~e l Electrical Lobel Mobile Home TOTA& AMOUNT DUE:' SOLAR .SS OcCUI?mtC1/ Group: LOT TYPE 1/10. . Interior Corner Panhandle CUL-de-sac x Value I I I I I I I I . (0.00 I . cf{) I (no 401' CHARGE I FEE I .If). 01) I ,LIO I r(J_(/O I. FEE CHARGE I I FSE CIIARGE I I I I. I I I I I I I I I I I W.~ol. P::::.ge 2 I' I I I I I I I I I REQ.- . L~,COG~ Bedrooms: Type/Car.st: I Lot Faaes - I Setbacks I P.L. House Caraqe Access. INorth lEast ISouth IWest I Enerau Sources Heat Water ,!Jp.atp.1' Range Fireo'Laca WoOd:;tOV6 TilDe Fees Building Value & Permit This permit is granted 071 the express condition that the sdid aonstI'Uation sha'Ll, in all respects, conform to the Ordinance adopted by the City of Springfield, incZuding the Zoning Ordinance, regu'Lating the ccnstI'Ucticn and use of buildings, and m~y be suspended or revoked at any time upon vic- lation of any provisions of said Ordinances. I Plan Check Fee: IVate Paid; I Reaeipt #: I Signed: Plumbing Permit No person Dhall constM.lct, instalZ.,' aUeX' 01' change any ....ew 01" existing plumbing or drainage system in whole or in part, unless such person is the legal possessor of a valid plumber's license, except that a pe~son may do plumbing work to property which is owned, leased Or operated by the appli- sant. Electrical Permit rVhere State LaLJ requires tr.at the electrical work be done by an Electrical Contractor, the electrical portion of this permit shall not be valid until the label has been signed by the Electrical Contractor. I I . Mechanical Permit I . PLan Examtner va!:e I HAVE CAREFULLY EXAMINED the completed application for permit, and do hereby certify that all infor-mation hereon is true and correct, and I further certify that any ar.d all work perfoP.7led shall be do:1e in accor- dance "nth the Ordinances of the City of Springfic1.d, and th< Lo:.i. of tho State of OregQn pertaining to the work described herein, and that NO OCCU- PANCY will be rtrlde of any structure without permission of the Building Di- vision. I further certify that o~ly contractors arMi employees who are in c~pliance with ORS 701.055 will be used on this project I. jU, iCMd<<k- f/~/~s- Date. Signsd . - c., _..1 . '. . ~"'r1 -- ~,..p~~,~- ""h-J~ I'-~a .4. : . I . - r:-~ --l.t-: i~- I . .f'~ r -.. ~~. , --: :. I I. !: 'r:\ , :1 1\.V " L-~, --l n "'" , . . JJJ " " -: .s:------ I. , . ." ,J ~. ~,z.p..:;e:.. .. , " . )-_. I , r . , I 1 " , e,,<.U;'1"Ir-Jet "'. "'l..-l- . " . ~ ~ .~ ~.~~-~.~ ~~~~ ~ ..~: ~I"='T" v-M I I LJ"L.rr1' I'-"t1 . , . . ' t ..' f"L-r-rl - --- - lIe}' ~~~~~ 1?'t-l1'- ~ i . t:I- ~. fl--fZ ~1'V u.. ~u ~......:; .oN ~,r.~\ "'II ,e;.' ...rM-lloJl.Jtj "t L.,,:.. '\2:> fb":of 1j- f'\'~. p.JO ~ f>WZ"'IZ- ~f~P1"",f2-f::. 1<;' '" ~~.*._-_._..~- ~e:=-.c.-n"",,;;;l rr lIb' , ~ ~L.oo Z....,. fl:'t"I C (..., Il"~ ~ ~r""'1b """"f DF'.w,o.L.c.... ~ . ::;:::::1""" , ~, ~f"""'~ f'! t.. ~~ J..;;"e1 M~'~ ~ - -~-- ~;. ?>II_pi! . ~I' r.I' -F--':;:' j"j ,-It, ,if, PETERSON ---------..----- - RESIDENCE. ---..---..-- . COLLECTOR DETAILS ---- -JZ.-- . m~~~~ ~~~tD A.fe~ . ~ ? ~ \\1WAM A. 1lA/l0ALl ~ 'q . ~ ~t_~.~ · EUGENE. OREGON ~:...;,., $ ~1~lJrf)"~ 7"'t (;:>- '7~ e>e> I:?ME::'.z.-ot~11e<l? ~rJ f;>f:y../fZ. . .... ~--4ul_-,zj,T-- ~ -rpP"'~'~~''1' . ""'."-- .' - .,~ . .._ R C.'H If. E C fUR E '" CQ.N11lY a..... IOillO sum QCII n.G'" OfIfG(l<olI')oO )44.)))) It. '. \ .. rsOi..AHA~-T-SCHEMATic' L_ _-'-_____ _~---_-----(,--- ,.~__ . . r,.~~ : . hL_~1 -~ .-....--'~.. ----..-_ __._ --:-_.uw..:..,._--," L~!~!I~~~E!!!.~_AJ~ EX~~A~~~I!l_:- -:ll- '" ] . ~-... , .- , ~;~~;1. l:.__~ . - . [COL~~CTi~Ri1' tTO '. t..:..~. 'A"n-' ' ~;E~~ -~~~V~ [~~;~ ~LVE' . rc~-~D'I~- . . L-,_ f';OT OUT rT~~~~: - ~IXINQ VALVE. --- -..U' IUNION. ~ - ---, -, - - L_...__ ., I ~~~!~E-R~~A~N- ~\.~tD A/~ ~ ~ i;j W1ll~ A. RANDiIU. :c1'l I:lc: \lS\U.;~.12~~ · EUGENE. OREGON · ,~ ~ "4/'1 OF ~\.~~ t " E~~~~~~.G"~ ,~~1 .. ,~ . . 5. GENERAL INFORMATION FOR INSTALLATIONS We consider that the Solahart 300LJ solar hot water system Is the most technically advanced thermo- syphon solar water heater available, designed to incorporate a sealed water circuit lor the solar collectors. separate Irom the mains water stored In the tank. This development enables higher performance solar collectors to be coupled to the solar hot water system, and also eliminates concern about collector corrosion In areas with poor quality water supplies. . In areas subject to Ireezing temperatures, this closed collector circuit must be IlIIed with a special long- 1I1e Solahart 'HARTGARO' solution to provide the Ideal method 01 Irost prevention. without the need for electrical energy. Input or special control valves. The Solahart 300LJ solar hot water system should be Installed In accordance with all local codes and authority requirements. TECHNICAL DATA 300LJ CAPACITY STORAGE TANK SOLAR COLLECTORS DIMENSIONS OF TANK DIMENSIONS OF COLLECTORS . OVERALL SIZE OF INSTALLED . SYSTEM Storage tank Closed circuit (collectors and Jacket) Empty Full Empty Full Overall length Overall height Overall width Cylinder diameter Jacket clearance Length Width Depth Length Width Height - Valve settings lor hot water circuli Pressure limiting valve (water Inlet) Expansion valve (water Inlet) Pressure-temperature rellel valve (on tank) Normal operating pressure (storage tank) 450 kPa (64 psi) 600 kPa (85 psi) 860 kPa (125 psi) 990C (210oF) 600 kPa (85 psi) Pressure rellel valve Normal operating pressure range Sale pressure with empty tank Sealed closed circuit 80 kPa (12 psI) -10 to 60 kPa (9 psI) 100kPa (14 pSI) ELECTRICAL COMPONENTS The rating 01 the electrical element Is shown on the nameplate 01 the storage tank. All electrical back . up heaters are designed lo[ operation at 220V to 260V Irom single phase 50 Hz or 60 Hz electrical supplies. Standard models Nominal rating 2,400 Wans . I.A.P.~.O. APPROVAL 15-1834 240V - 10 Amps . '. 5 -. 300 IItres (80 gaij 22 Iitres (6 gall 54 kg (165 Ibs.) 397 kg (674 Ibs.) 2 at 40.0 kg ea (88 Ibs.) 2 at 43.5 kg ea (96 Ibs.) 2290 mm (90") 510 mm (20") 510 mm (20") 430 mm (171 - 5 mm (0.21 1942 mm ea (761 1026 mm ea (40") 80 mm ea (31 2456 mm (971 2320 mm (g21 510 mm (201 . 220V - 9.2 Amps '. , . . , . 7. INSTALLATION DIRECTLY ONTO A SLOPING ROOF (WITH PITCH/SLOPE) WOOD SHAKE, SHINGLE OR COMPOSITION ROOFS' , Selact a suitable section 01 roof area approximately 2.5 M x 2.5 M square and approximately 600 mm Irom the rool ridge In a shade free area. , Check In detail that the area selected is capable of supporting the weight 01 tha Installed Solahart system. Carry out any necessary additional support as required by standard engineering calculations. Layout lour lenQlhs 01 2,450 mm long 50 m;" x 100 mm exterior construction grade wood and locate lour roof trusses or support members beneath the rool covering. Fix the wood runners to them, running with the slope 01 the rool, and using 12 off 8 mm diameter x.15Oinm~long.lag bolts..Alternatively. 12__. off suitably sized J bolts can be used In place 01 the lags. (See Diagram No.2) , Insure that the 3 lag bolts or J bolts on each wood runner are securely located In or around the trusses or support members by checking In the ceiling space belore and after drilling. Insure that sufficient water- prooling compound Is Injacted In and around any panetrations In the roofing material. The water- prooling compound and its application should be such that ABSOLUTELY NO WATER LEAKS through the rool will occur. The waterprooling should be capable 01 remaining Intact through normal contraction and axpansion 01 the rool structure and covering. It should be a long-life type. Insure that the lour wood runners lollow the slope 01 the rool and do not run across . the slope 01 the roof, ara parallel and In Iina by measuring outer timbers corner-to-corner. The purpose 01 the wood runners is to provide a stable and level base (in which to mount the Solahart system.' - It will also allow Iree flow 01 rain water down the rool slope and prevent damming against the high side 01 the tank. Locete tha collector support .extruslon (PN.0829) along the lower ends 01 the 50 mm x 100 mm wood runners. (Flat side 01 upstand lacing the collectors.) Fix the coli actor support extrusion in place with lour 8 mm diameter x 40 mm lag bolts. Insure the location Is level.. Install the 2 solar collectors in place, resting the lower part 01 both collectors onto the collector extrusion with the wood runners supporting the collectors. Check and Insure that each collector Is flttad with rubber 0 rings (PN.o171). (One spare 0 ring Is provided In each Solahart Small Parts Kit.) Join both collectors with collector unions (PN.0694) applying medium pressura with spanner. Check collector overhang beyond the collector extrusion Is approximately 220 mm each side lor asthetlc appearance. Fit the copper blanking disc (PN.060S) and brass collector nut (PN.0601) Into the top right hand corner of the right hand collector. Fit the collector fill assembly (PN.1617) and collector nut (PN.OB01) Into the lower left hand comer 01 the left hand collector. Fit the collactor hot. pipe (PN.0710) to the top left hand corner 01 tha left hand collector, Fit the collector down pipe (PN.0703) to the lower right hand corner 01 the right hand collector. Fix the collectors In place by attachIng the collector clamps (PN.0843) to the collector extrusion as per the exploded view Diagram No.1. Permanently fix the clamps In place with sell-tapping screws. position the storage tank on the rool above the collectgrs, lining up the connection pipes. Fit the . connecting pipes to the storage tank. Insuring eachu ,n. connection Is lilted with a rubbar 0 ring: " With the tank located In position end the closed circuit pipe connections made, fit the lour aluminum tank clamps (PN.0874) along the rear loot or support . moulding of the tank base (sea Diagram No.3). Insure the tank Is level and not pushing onto the collectors or plpework. Fix the tank by securing the lour tank ,clamps to tha wood runners with 8 mm diameter x 40 mm long lag bolla Fit the pressure temperature rellel valve (U101). Into the tank as per the exploded view Diagram No.1. '. , Thoroughly Inspect the entire installation to Insure that It is rigidly fixed down, ell pipe connections are tightened, the tank and collectors are level and that adequate waterproofing and sealing 01 all penetrations has bean carried out Once this inspection has been carried out REMOVE THE TRANSPARENT PLASTIC COVER FROM THE TANK BODY AND FIX IN PLACE THE SELF-, ADHESIVE "SOLAHART" LOGO TO THE TOP LEFT HAND CORNER OF THE TANK. WARNING: If plastic cover Is left on the tank and exposed to tha sun lor a law days it will bake onto the aluminum and be Impossible to remove. DIAGRAM NO.3 SECURING TANK TO WOOD RUNNER , ~ ,'0S'll .......... WOODAUHNP ."""..e_ ...- ,. 9 . . ~ " . . DIAGRAM NO, 2- .--...,. .-., -- ou_ WOOD SHAKE. SHINGLE OR COMPOSITION ROOFS (WITH PITCH/SLOPE) - '-0 ... _ ._." . . Collector extrusion supported by and secured to wood Nnnera by 8 mm die x 40 nun lag bolla. Collectora held down by collector clamps. o. .~.... '" .~ . .. . .._ J... ~l..~ ,., .. " 8 mm die x 40 inm.,lsg bolt " throu9h tank clamp to each wood Nnner. 1/00F~ tJs.s 01/ S 8 mm die x 150 mm lag or' tJPP01/J' Af J boltS total 3 each wood Nnner. EAfSEIl Install 150 mm from ends end at mid- length predrill and counteralnk. Completely water seal each penetration. ~ 4 EXTERIOR CONSTRUCTION GRADE WOOD RUNNERS SOmmJll100mm. . ~- u. 1 j ~ 11'-'" II -~ 810mm SECTION WITH ROOF RAFTERS AT 610 mm CENTERS ] ,"",I IZPo-I ~ f~ Jx 1~WOOD RUNNERS ON 4 ROOF MEMBERS. lr~.-' 810mm -........... ...._....~_.~.... ....... .......- u \111 l ff . J SECTION WITH ROOF RAFTERS AT 400 nim CENTERS. l '1m. l"ltl u u ~ 50~ 100 WOOD RUNNERS ON 4 ROOF MEMBERS. " _ 400 mm - 400 mm'- 10