Loading...
HomeMy WebLinkAboutOccupancy Correspondence 1983-11-29 fsJf~t:, 0.;;. UNITED STATES POS " 'SERVI OFFICIAL BUSI P t.A ! ~ , .~ bo. SENDER INSTRU&1'iDNS, - ~ - PrInt your namt, addr_ and l1P eoJeJn thi $baCt ~lOw, . Co.telleml1,2,3.and.on-'tI\t..~1~~ . AlladIlofronlofI/tld8U_pem;to,.-- otherwlslalllxtobaclcoll1tlde. End....1I1Jdt "Relum Recelpl Req""e<r adJaCtllI to number. RETURN .. TO - --- ---..................................~-----.---- ~_..-w'"'.--.::~ ~ ~~~-,::...- ~ .,.,.""~.." - PENM:Wf~ ." U5E10_, ~I\lMENT"":='" ~.~ \:OiF Posl'~QE:'3lSO ~f''''''''''--'- '~~ '- "_. .......- U.S.MAlL . @, CITY 0~a~~l~r1CL~ DEPAPTM;NT OF PUALIC WORKS 225 NORTH 5th STREET SPRINGFqR~t 0RmC!lN) 97477 (City, Slate, and ZIP Code) ;JI 6' 0 SENDER: Complete items 1, 2, 3, and 4. a Add your address in the "'RETURN TO"' space ~ on reverse. ~~~I.! . CQ..9U. (COI\1SUL T POSTl'ilASTER FOR FEES) i " The following service is requested (check ooe). xiacshow to whom and date delivered. ....."............. o Show to whom. date, and address of delivery.. 2, D RESTRICTED DELIVERY (The restricted dd.iptfy fee is chorged in addition to therelurn receiptfee.) ~ ~ _t , TOTAL . 3. ARTICLE ADDRESSED TO: Ms. Carol Smith :Jl !!l 2238 Debra Drive !ii Springfield, Oregon z :II m n m ~ 97477 4. TYPE OF SERVICE: , D REGISTERSl D ",SURED xn....o;n....""" 0 COD OEXPRESS t:lAIL (Ah'_ _n 8lenature of add,essee 0' agent) [ have received the article d "bed above. DAD th ARTICLE NUt1BER 329965142 ~ agent 11 ___ , I I I 'I \ I / .. . r SPRINGFIELD CITY OF SPRINGFIELD Department of Public Works November 29, 1983 CERTIFIED LEITER / Ms. Carol Smith 2238 Debra Drive Springfield, Oregon 97477 RE: Occupancy Inspection at 2238 Debra Drive, Springfield, Oregon Dear Ms. Smith: At your request the Springfield Building Safety Division conducted an Occupancy Inspection at the above referenced address. The proposed use of a portion of the building as a day-care facility will cate- gorize its usage as an E-3 Occupancy. A Conditional Use Permit, granted by the Springfield Planning Commission, is re- quired for this occupancy located within property zoned RL, The Conditional Use' Permit application is to be initiated by the property owner through the Spring- field Planning Department. The following items shall be installed, replaced or repaired in order to conform to the applicable code standards for that occupancy, STRUCTURAL SPECIALTY CODE AND FIRE AND LIFE SAFETY CODE (S.S.C,) 1. Inadequate design and assembly of the patio roof support system has ~an unreliable safety condition relative to the structural longevity ~atio covering. Areas of immediate concern are the overspan of the 9Y 4 inch rafters and their attachment to the existing building. .... produced of the 2 inch The patio covering shall be completely removed or repaired in accordance with applicable design standards for that type of construction, 2. All glazed panels that have been damaged, creating a potential safety hazard, shall be replaced. 3. The wall and ceiling coverings in the remodeled garage area have not been ~roperly attached to the wall and ceiling supports. The maximum spacing o~ fasteners, measured from center to center shall not exceed 7 inches. 4. An inspection by the Springfield Fire Prevention Bureau relative to smoke detector requirements and fire extinguisher locations shall be conducted and their findings are to be included as items required for this occupancy, 225 North 5th Street · Springfield, Oregon 97477 . 503/726-3753 / .' . Ms. Carol Smith Occupancy Inspection 2238 Debra Drive November 29, 1983 Page 2. r / ELECTRICAL SPECIALTY SAFETY CODE (E.S.S.C.) 1. The grounding of electrical equipment is essential to reduce the possible hazard of electrical shock when a ground fault occurs within the electrical system. In- / stalling grounding type duplex receptacle outlets and the 'bonding of the electrical equipment in the areas where the children will be located will minimize the pos~' sible danger from electrical shock. 2. To provide protection from the possibility of fire due to w~r~ng defects, exten- sion sleeves shall be installed in all outlet boxes that are not flush with the finished wall surfaces. 3. To prevent the loosening of conductor splices and terminal connections, the wall switches and receptacles shall be properly secured to their outlet boxes. 4. The service panels must remain readily accessible at all times for emergency purposes and maintenance. Remove the shelf built directly in front of the sub- panel and maintain the necessary clearances for accessibility to the panels, 5. In the situation of a fire, all electrical wiring in a residence shall be capable of being disconnected from one location. The sub-panel (extension service equip- ment) shall be protected by a sub-main disconnect within the main service panel. 6. The improperly installed and defective lighting fixtures create a potential shock and fire hazard. The electrical contractor shall check all fixtures and make the necessary repairs or replacements. PLUMBING SPECIALTY CODE (P.S.C.) 1. To prevent the possibility of ~nJury or interior water damage resulting from the possible release of scalding water from the pressure relief valve mechanism, the . valve discharge opening shall be piped to the exterior of the building and turned downward. i . All necessary permits shall be obtai~ed and required inspections approved before a Certificate of Occupancy will be issued. Please direct all inquiries to the Springfield Building Safety Division at 726-3753. <::Lc\. ~,-,~Y--- David J. Puent Building Inspector/Plans Examiner ~ ,\, ~ DJP/lh