HomeMy WebLinkAboutPermit Correspondence 1994-2-25 13/0 ~y '< I '\ "'d.C\CS ~~ ~~~.orQ This home has been profest:' """ally Insulated with Owens-Corning Fiberglas@ Insulation .m To meet the stated thermal reslstances(R-Values), the manufacturer provides the following specifications. Blanket Insulation Blanket and batt fiber glass Insulation when Installed according to the manufacturer's recommendations will prOVide the stated R-Value Minimum Thickness R-Value To Obtain an Insulation resistance Rof Installed Insulation should be Advanced ThermaCube Plus@ Loose Fill Insulation 03M04269 Stated R-Value IS prOVided by installing the required number of bags per 1,000 sq ft at a thickness not less than the label minimum thickness Installation of the required number of bags may Yield more than the speCIfied minimum thickness and minimum sq ft weight Failure by the Installer to prOVide both the required bags and at least the minimum thickness Will result In lower insulation R-Value SpeCification For Open Blow AttiCS Nominal net weight of insulation per bag IS 35 Ibs ~ 1!2'.@1!/il16K> BAGS PER MAXIMUM MINIMUM MINIMUM R-VALUE' 1000 so FT NET COVERAGE WEIGHT so FT THICKNESS R-38C 10'/'" Thick ~ To obtain an No _of bags per Contents of thiS Weight per sq ft Installed "-9'k" I ntcKo!D Insulalion 1000 sq ft of bag should not of Installed insulation R-30C 8'/'" Thick resistance net area shall cover more than Insulalion should should not R-25 8" Thick R of not be less than not be less than be less than c.8-22 _ 63/4' Thick ._~~ 263 38 Sq Ft 0922 20'/2 In R-2~ ~ R-44 233 43 Sq Ft 0822 18'/2 In R-38 200 50 Sq Ft 0705 161n -~ C::627]'3IJll~ R-30 156 64 Sq Ft 0550 123/4 In R-15 3W' Thick R-26 135 74 Sq Ft 0474 11 In R-13 3W'Thlck R-22 114 88 Sq Ft 0399 9'/2 In R-11 3W' Thick R-19 98 102 Sq Ft 0343 8'/4 In R-11 56 178 Sq Ft 0197 43/4 In t R-18 in a 5'/,' cavity Unfaced Insulation IS branded to Identify R-value R-11 3 stripes R-13 4 stripes R-15 2 stripes R-19 5 stripes R-21 4 stripes R-22 R-25 R-30 R-30C R-38 R-38C 6 stripes 1 stripe 2 stripes 3 stripes 4 stripes 1 stripe 'The higher the R-Value, the greater the Insulating power Ask your seller for the fact sheet on R-Values All Insulations vary In thermal performance due to factors such as aging, mean tempera- ture, settlement, convection, mOisture absorption and Installation vanatlon Convection In glass loose-fill insulation Installed In open attics can reduce ItS thermal performance at extreme winter temperatures dunng the heating season Glass fiber batts and blankets ARE NOT Impacted by convection AdvancedThermaCube Plus may deliver reduced thermal performance due to convec- tion at low outSide temperatures AdvancedThermaCube Plus has been deSigned to antiCipate thiS phenomenon and prOVide the labeled performance on average over the winter heating season The dollar Impact to a homeowner's annual heating costs from loose-fill convection IS estimated to be minimal If any when compared to labeled perfor- mance For more Information on the performance of Advanced ThermaCube Plus contact your local Owens-Corning representative The follOWing products have been Installed as specified above Type (Check appropnate box) kraft unlaced 1011 FS-25 loose 1111 ~~OVJ Ceilings . ~ 4!? 0 ~ ~ 5,t.,~o<" . r o.u..I."\ o ...."",\ 0 0 0 0 'U..",-'i: Floors 0 ~ 0 0 0 R\~K\ 0 0 0 0 0 \.l'<f; Walls ~ ~) 0 0 0 \.\.~ 0 0 0 0 0 "'t<L'n Installed by: HOME INSULATION CONT. INC. 34155 HWV 99E TANGENT, OREGON 97389 · 926-7831 signature R-Value Thickness \{- u.. q ';;;>,0>;;>." R-06 \~ " \;.= ""\'~. l{.-:o,C o.,}~ " ~.\\ V""'i)..\\ \\'~'i-\ Io~~ lo~lO.I ~l,.:::l." R.~\ V:,l:J." p'.~\ Coverage Area \\COO<\ No Pkgs ~"\<'''''V<>.\A..\\, ,,\....\~w...\, 'd" I'O.f"f" ..~, \ \ ",.......... ~ ~ ~,O':>(" o..~\)~ n~\~ "'....~,,<'if;, \ ~\.....\..:... \...::1:0.\<"", 'If(,,,,,,,, \,',<> \\'? SII.. \\~~ \, 'Q date BUilder: ~CL ~C\.\ \ slgna~re ~"'~~ date d.' d. S-C\. '-\ @ Fiberglas IS a registered trademark of Owens-Corning Fiberglas Corporation COPYright @ 1992 Owens-Corning Fiberglas Corporation Pub No 15-BW 14840-C Litho In USA. November, 1992 OWENS-CORNING WORLD HEADQUARTERS FIBERGLAS TOWER TOLEDO, OHIO 43659